background image

 

 

Linear Console Power Supply 

USER GUIDE

Publication AP5716 

RPS14

Summary of Contents for RPS14

Page 1: ...Linear Console Power Supply USER GUIDE Publication AP5716 RPS14 ...

Page 2: ...erformance and reliability for which this equipment has been designed and manufactured read this User Guide before operating In the event of a failure notify and return the defective unit to ALLEN HEATH or its authorised agent as soon as possible for repair under warranty subject to the following conditions Conditions Of Warranty 1 The equipment has been installed and operated in accordance with t...

Page 3: ...he ground connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power supply unit to rain or moisture or use it in damp or wet conditions Do not place containers of liquid on it which might spill into any openings Ventilation Do not obstruct the ventilation slots or position the power supply unit where the air flow required for ventilation i...

Page 4: ...he power supply unit cosmetics avoid placing heavy objects on the unit scratching the surface with sharp objects or subjecting the power supply unit to rough handling and vibration Environment Protect from excessive dirt dust heat and vibration when operating and storing Avoid tobacco ash smoke drinks spillage and exposure to rain and moisture If the power supply unit becomes wet switch off and re...

Page 5: ...R CABLE Part number 002 583 Connects the RPS14 to the mixing console DOCUMENTATION including Safety Sheet AP3345 this user guide AP5716 and the Registration Card AP3594 The RPS14 The slimline RPS14 power supply unit is a high performance low noise linear power supply producing DC voltages by rectifying smoothing and regulating AC voltages from the secondary windings of a mains transformer Allen He...

Page 6: ...this reason power supply units supplied with Allen Heath ML series mixing consoles are provided with a long 2 9m output cable to enable them to be positioned away from the mixing console Backup power supply units bought separately are provided with a shorter 0 75m output cable to combine power supply units For the same reason when rack mounting it is preferable to avoid locating the unit next to s...

Page 7: ...ltage fluctuations immediately switch off the power supply unit and disconnect from the mains supply Combining Power supply units The RPS14 has a built in combiner allowing direct connection to another power supply unit for backup It can be combined with either another RPS14 or the alternative MPS14 power supply unit Either can be used as the main or backup supply Connect the two power supply unit...

Page 8: ...l specification Mains Input Voltage Range Internally wired for region 100V 10 50 60Hz 120V 10 50 60Hz 220V 10 50 60Hz 240V 10 50 60Hz Note Contact Allen Heath if your local mains voltage is not shown above Power consumption max 650W Mains Fuse 100 120V T10A 250V 20mm A H Part no AL3455 220 240V T8A 250V 20mm A H Part no AL0487 Internal Fuses PCB Ident Fuse type F1 17 5V T 16A 250V 20mm A H Part no...

Reviews: