BEFORE TURNING GAS SUPPLY ON

1. You heater was designed and approved for outdoor use only. DO NOT       

    use it inside a building, garage, or any other enclosed areas.

2. Make sure surrounding areas are free of combustible material, gasoline,  

    and other 

fl

 ammable vapors or liquids.

3. Ensure that there is no obstruction to air ventilation. Be sure all gas 

    connections are tight and there are no leaks.

4. Be sure the cylinder cover is clear of debris. Be sure any component 

    removed during assembly or servicing is replaced and fastened prior to     

    starting.

BEFORE LIGHTING

1. Heater should be thoroughly inspected before each use and by a 

    quali

fi

 ed service person at least annually. If relighting a hot heater, always      

    wait at least 5 minutes.

2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or            

    wear. Suspected areas should be leak tested. If the hose leaks, it must be

    replaced prior to operation. Only use the replacement hose assembly        

    speci

fi

 ed by manufacturer.

LIGHTING

This heater is equipped with a pilot light that allows for safer startups and 

shutdowns. Pilot must be lit before main burner can be started. 

1. Turn the control knob to the “OFF” position.

2. Fully open LP cylinder valve.

3. Push control knob in and rotate to pilot position.

NOTE: FOR INITIAL START OR AFTER CYLINDER CHANGE, HOLD CONTROL 

KNOB IN FOR TWO (2) MINUTES TO PURGE AIR FROM GAS LINES BEFORE PRO-

CEEDING.