manualshive.com logo in svg
background image

AGM-2100

BLOOD
GLUCOSE
MONITORING
SYSTEM

A112DA302
04/2016

User Manual

Blood Glucose Monitoring System

#7102~7107, #7402, #7403, #7406, 140, 

Beolmal-ro, Dongan-gu, Anyang-si, 

Gyeonggi-do 431-804 REPUBLIC OF KOREA

www.allmedicus.com

        Manufactured by

All Medicus Co., Ltd.

EU Representative

MT Promedt Consulting GmbH

Altenhofstr. 80, D-66386 St. Ingbert, Germany

Tel.: +49 6894 - 58 10 20

Содержание GlucoDr AGM-2100

Страница 1: ...ose Monitoring System 7102 7107 7402 7403 7406 140 Beolmal ro Dongan gu Anyang si Gyeonggi do 431 804 REPUBLIC OF KOREA www allmedicus com Manufactured by All Medicus Co Ltd EU Representative MT Prome...

Страница 2: ...the power button to turn on the meter Insert a test strip Check the code number The code number displayed on the meter must match the one on the test strip vial Apply the blood drop to the side edge...

Страница 3: ...This User Manual will tell you all you need to know about the system and how it works Please read this carefully before using the meter Thank you for using Blood Glucose Monitoring System...

Страница 4: ...n temperature may cause inaccurate test results in reading When taking the meter from cold to warm area or from warm to cold area let the meter sit for about 30 minutes to adjust to the room temperatu...

Страница 5: ...ter the expiration date printed on the vial Do not bend cut or alter the test strips Do not insert the same test strip into the test port multiple times It can lead to an improper operation Safekeepin...

Страница 6: ...Meter Memory Function Setting the Meter Caring for GlucoDrTM Meter Additional Information Table of Contents Understanding Your Test Results l 20 Recalling the Previous Test Results l 21 Checking the...

Страница 7: ...cose Monitoring System 1 7 Upon request of distributor actual package may consist of all or part of items described above Carrying case User Manual GlucoDrTM Meter GlucoDrTM Test Strips Batteries Lanc...

Страница 8: ...mple messages appear here LCD Display Code Button Memory Button Recall the stored test results in the MEMORY MODE or change the code number in the CODE MODE Enters into the CODE MODE while pressing th...

Страница 9: ...Battery Cover Test Port Insert the GlucoDr Test Strip for testing Then the meter turns on and displays the code number automatically...

Страница 10: ...ry life STRIP ICON When the STRIP ICON blinks insert a test strip to the meter BLOOD DROP ICON When the BLOOD DROP ICON blinks apply blood sample TEMPERATURE ICON When the meter is not used at a recom...

Страница 11: ...to insert or remove test strip Grip Make sure the confirmation window fills completely Confirmation window Reaction chamber Insert into test port Gold electrodes Apply blood sample here blood is abso...

Страница 12: ...on the test strip vial Checking the Code Number Press the power button to turn on the meter Then the code number STRIP ICON and BLOOD DROP ICON will appear Turn on the Meter Make sure that the code nu...

Страница 13: ...use it will cause the meter to exit the CODE MODE Enter the CODE MODE With the code button button pressed use button to adjust the same code number printed on your test strip vial Change the Code Numb...

Страница 14: ...e code number is correctly adjusted release the code button button A new code number will be saved and appear on the meter display Save the Code Number To change the code number faster press and hold...

Страница 15: ...When you open a new vial of test strips When you think that the test results are not accurate When you drop the meter When you suspect your meter or test strips are not working properly When your bloo...

Страница 16: ...tches the one on the test strip vial If the code numbers match you can start the test If the code number on the meter doesn t match the one on the test strip vial adjust the code number on your meter...

Страница 17: ...Solution only It is used to check the performance of your meter and test strips It is NOT a recommended range for your blood glucose level 11 Compare the control solution test result to the control so...

Страница 18: ...vial well Code number printed on the test strip vial does not match the one displayed on the meter Meter test strips or control solution are kept too warm or too cold or Meter malfunction 1 If your c...

Страница 19: ...lancet it will be used to dispose the lancet safely after its use Insert a Lancet into the Lancet Holder Turn the cap of lancing device clockwise until it fits Replace the cap Before using the lancing...

Страница 20: ...Charge the Lancing Device Place the lancing device carefully on the tip of your finger and press the release button Lance your Finger Place the protective disk on a flat surface With the used lancet...

Страница 21: ...al sterilized lancets are BD Ultra Fine E Z Ject G P Lite Microlet Monolet Soft Touch Ultra TLC Unilet GP and Greenlan Note Not recommended lancets in the above list may not work properly with the lan...

Страница 22: ...17 GlucoDrTM Meter GlucoDrTM Test Strip Lancing Device Lancets Performing the Blood Glucose Test with GlucoDrTM 1...

Страница 23: ...e number displayed on your meter and the test strip code number match Insert a Test Strip Do not force the test strip into the meter This may cause malfunction of the meter Obtain a blood drop from yo...

Страница 24: ...o the arrow on the test strip as directed Do not put blood on the top of the test strip Apply the blood drop to the side edge of the yellow window of the test strip If there is an insufficient amount...

Страница 25: ...ntdown from 11 to 1 your test result will appear on the meter display If you remove the test strip the test result will be automatically saved in the meter memory Results in just 11 seconds Hold the u...

Страница 26: ...st strip are working correctly you must contact your healthcare professional immediately Expected Values1 Criteria for the diagnosis of non diabetes Fasting plasma glucose FPG 70 100 mg dL 3 9 5 6 mmo...

Страница 27: ...ess button with the meter turned on Press Button 1 Press and release button once to make the most recent test result appear on meter display Every time you press and release button the meter will disp...

Страница 28: ...Press and release the code button button once to exit from the MEMORY MODE Exit the MEMORY MODE Press and hold button in the MEMORY MODE in order to view the test results faster...

Страница 29: ...and Hold the Power Button for 3 seconds To enter the UNIT SELECT MODE With the meter turned on press and hold the power button until mg dL or mmol L appears on the meter Select the Unit of Measurement...

Страница 30: ...re times but the battery should be replaced to new one as soon as possible If bAt appears on the meter display the meter will not operate The battery must be immediately replaced Press the power butto...

Страница 31: ...down until you hear the cover click into place Close the Battery Cover Press down the top of the battery cover then pull it out The battery cover will be released Remove the Battery Cover Remove the o...

Страница 32: ...s countdown from 11 to 1 while calculating a blood glucose test result Insert a test strip into the test port of your meter Make sure the code number displayed on the meter matches the one on the test...

Страница 33: ...your system is working correctly contact your healthcare professional immediately Your blood glucose result is lower than 20 mg dL 1 1 mmol L Repeat the test using a new test strip and or check the sy...

Страница 34: ...esults Turn off the meter and replace the battery immediately The meter has some problems while testing blood glucose Retest with a new test strip If this error message displays again please contact y...

Страница 35: ...r incompletely Replace the batteries Check if batteries are correctly installed See pages 24 25 Contact your local distributor Insert the test strip correctly with the printed side facing up Not enoug...

Страница 36: ...onitoringSystem AGM 2100 Electrochemicalmethod Freshcapillary wholeblood 4 minimum2 5 20 600mg dL 1 1 33 3mmol L 11seconds Plasma equivalent Two3 voltlithiumbatteries coincelltypeCR2032 Approximately4...

Страница 37: ...ntration 75 mg dL 4 2 mmol L Repeatability using venous whole blood Level 32 8 mg dL 83 4 mg dL 114 mg dL 193 mg dL 279 mg dL 3 7 mg dL 3 3 mg dL 4 4 mg dL 6 9 mg dL 9 0 mg dL SD 11 1 3 9 3 9 3 6 3 2...

Страница 38: ...product fulfills the requirements of Directive 98 79 EC on in vitro diagnostic medical device For in vitro diagnostic use Do not dispose the instrument in the urban waste Consult User Manual Explanati...

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ......

Отзывы: