Description

VIDEO OUT  

(CVBS, VGA, HDMI)

CVBS - BNC connector for video output 

VGA - DB15 connector for VGA compatible monitor. See specifications for supported resolutions. 

HDMI - Two HDMI connectors for an HDMI compatible monitors. See specifications for supported resolutions.

LINE IN

RCA connector for audio input

RS-485, ALARMS IN/OUT

See below, next topic

Power connector

AC 100V ~ 240V power supply.

ON / OFF Switch

Switch for powering the device on or off

GROUND

Terminal for ground. Connect to earth ground before powering on the DVR.

LAN Interface

2 x 10/100/1000BASE-T Ethernet network interface 

USB interface

Universal Serial Bus (USB) ports for additional devices such as USB mouse and USB Hard Disk Drive (HDD).

AUDIO OUT

CVBS AUDIO OUT - RCA connector for audio output. This connector is synchronized with CVBS video output 

VGA AUDIO OUT - RCA connector for audio output. This connector is synchronized with VGA video output

HD-TVI video inputs

HD-TVI interface for video input

RS-485, ALARMS IN/OUT

Item

Description

RS-485 (T+, T-, R+. R-) 

T+ and T- pins connect to R+ and R- pins of PTZ receiver respectively.

KB

Controller port:  

D+, D- pin connects to Ta, Tb pin of controller.  

For cascading devices, the first DVR’s D+, D- pin should be connected with the D+, D- pin of the next DVR

ALARM IN (1 through 16)

Alarm inputs 1 - 16. Alarm input is tied to ground through the alarm sensor. See 

“Step 3. Connect alarm devices to the DVR” on page 

2

 for more information. 

ALARM OUT  

(1-G through 4-G)

Alarm outputs 1 - 4 with ground terminations. See 

“Step 3. Connect alarm devices to the DVR” on page 2

 for more information. 

This guide provides instructions to initially setup the ALI-QVR5016H digital video recorder (DVR) for AHD, HD-TVI, and 960H analog and 
IP cameras. For information about using your QVR and its extensive capabilities, refer to the 

Alibi Embedded Network Video Recorder 

Firmware V3.4.x User Manual

 provided at 

www.alibisecurity.com/resources

For more information

, refer to these documents - available from your equipment vendor: 

• 

ALIBI™ Tools Utility Installation and User Manual

• 

ALIBI™ Witness Smartphone App for Android - Quick Start Guide 

DVR Front Panel

USB Interface

Power LED

Status

TX / RX

ALI-QVR5015H front panel

Item

Usage

Power LED

Indicator turns green when DVR is powered up. 

Status

STATUS indicator lights in red when HDD is reading / writing.

TX / RX

LED indicator blinks green when network connection is functioning properly.

USB Interface

This port can be used for a USB mouse or USB flash memory devices.

DVR Back panel

Camera video inputs

LAN (2)

RS-485, 

Alarms IN/OUT 

Power connector  Fan outlet

ON / OFF switch

Video Out - HDMI (2), VGA

CVBS Video Out

CVBS, VGA Audio Out

Audio Line In

Camera Audio In

Ground

RS-232

eSATA

USB

Item

Description

eSATA 

Connects external SATA HDD, CD/DVD-RW

RS-232 Interface

DB9 (male) connector for RS-232 devices

ALI-QVR5016H 16-Channel AHD, Analog, HD-TVI, 960H and IP Camera Recorder Quick Setup Guide

Summary of Contents for ALI-QVR5016H

Page 1: ...und through the alarm sensor See Step 3 Connect alarm devices to the DVR on page 2 for more information ALARM OUT 1 G through 4 G Alarm outputs 1 4 with ground terminations See Step 3 Connect alarm devices to the DVR on page 2 for more information This guide provides instructions to initially setup the ALI QVR5016H digital video recorder DVR for AHD HD TVI and 960H analog and IP cameras For inform...

Page 2: ...t the jumper must be in Mouse control A standard 3 button left right scroll wheel USB mouse can also be used with this DVR To use a USB mouse 1 Plug the USB mouse into the either the front panel or backpanel USB connector of the DVR 2 The mouse will be automatically detected If the mouse is not detected the mouse may not be compatible with the DVR Please refer to the recommended device list from y...

Page 3: ... that HDD needs to be initialized by the recorder before it can be used place If connecting the alarm output to an AC loaded alarm the corresponding jumper must be removed Example If you connect an AC load to the alarm output 3 of the DVR then you must remove the JP 3 To remove a jumper for AC load alarm circuits 1 Disconnect all cabling from the DVR 2 Remove the DVR top cover 3 Locate the jumper ...

Page 4: ... interface full duplex 1 RS 485 keyboard interface Alarm in out 16 4 General Power supply 100 to 240 Vac Consumption without HDD 65 W Working temperature 14 ºF to 131 ºF 10 ºC to 55 ºC Working humidity 10 to 90 Dimensions W D H 17 5 15 4 2 8 inch 445 390 70 mm Weight without HDD 11 0 lb 5 kg to record data Select check the box for that HDD then click Init to initialize the disk NOTE Init will eras...

Reviews: