- 1 -
User Manual of Electromagnetic Lock
(
Model
:LM176)
☆
Technical Parameters:
A. Holding power: 280KGS
、
B. Working Voltage: 24VDC
C. Working Current:250mA D. Safety mode: Power-on to lock, Power-off to open.
E.
Typical Installation
:
Flushing
(
A
)
、
Hanging
(
G
)
☆
Installtion chart
Hanging Type Electromagnetic Lock Electromagnetic Lock fitting for all kinds of doors.
Flush Bonding Type
☆
Typical Installation
:
STEP 1
A
.
Fold template along dotted line.
B
.
Place template against door and head frame.
C
.
Drill holes as indicated on temple.
STEP 2
A
.
Mount the armature palte to door using 1 rubber washer sandwiched between 2 steel washer(the rubber washer and 2 steel washer are installed on the
through sexnut between the armature plate and door).
STEP 3
A
.
Install the mounting plate with 2 flat head screws(the 2 M5X5 flat head screws are installed in the solotted holes for adjustment).
B
.
Adjust mounting plate so that it forms right angle with the armature plate.
C
.
Using the mounting plate as a temple,drill the wire hole.
D
.
Drill and remaining mounting screws.
STEP 4
A
.
Instal magnet to mounting plate with 2 M4 screws supplied.
STEP 5
A
.
Test all functions of this model(see wiring instruction).
Model
L1
L2
A
B
D
E
F
280GF/X
250
210
27
16.5
2.3
6
50.5