background image

52299

3500W INVERTER GENERATOR 

WITH PURE SINE WAVE

User 

Manual

Product

Info

www.powertoolsupport.com

Read all safety warnings and all instructions 

thoroughly before operating this product.

Ensure you keep your manual in a 

safe place for future reference.

IM ed13

Summary of Contents for Workzone Titanium+ 52299

Page 1: ...R WITH PURE SINEWAVE User Manual Product Info www powertoolsupport com Read all safety warnings and all instructions thoroughly before operating this product Ensure you keep your manual in a safe place for future reference IM ed13 ...

Page 2: ... website or contact details for example Advantage You are not required to manually enter a website address or contact details How it works To scan the QR code all you need is a smartphone with QR codes reader software and an Internet connection This type of software can be downloaded for free from your smartphone s app store Try it out now Just scan the QR code with your smartphone and find out mo...

Page 3: ...ssembly Compact Stand Alone Assembly 15 PortableWheeledTyped Generator Assembly 16 Assembly of the Main carry handle 17 Indicators 18 Preparing the Generator 19 Checking the Engine Fuel 19 Checking the Engine Oil 20 Engine Oil Replacement 21 Starting the Engine 22 Stopping the Engine 23 Failure of the Motor On Off Switch 23 240V AC Connection 24 Connecting apparatus to the Generator 24 Overload co...

Page 4: ...ages 26 31 Intended use of the 3500W Inverter Generator with Pure SineWave NOTE This product is for private domestic DIY use only It is not suitable for commercial or trade use This product is suited for home camping and caravan applications domestic house hold mains failure back up It will allow you to power outdoor lights power tools home appliances including sensitive electronic equipment inclu...

Page 5: ...nstructions for use carefully Low Oil Indicator Load Status indicator Refer to the instruction manual for advice Power Supply indicator Never use in the home or in partly enclosed areas such as a garages Exhaust contains carbon monoxide a poisonous gas you cannot see or smell Explosive material Do not operate in a hazardous location such as areas where there is a risk of explosion of petrol fumes ...

Page 6: ...t or recommended maintenance tasks Save all warnings and instructions for future reference 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents Rags cloths cord string and similar items should never be left around the work area b Do not operate power tools in explosive environments such as in the presence of flammable liquids gases or dust Power tools cre...

Page 7: ...the rate for which it was designed b Do not use the product if the switch does not turn it on and off Any product that cannot be controlled with the switch is dangerous and must be repaired c Ensure the product is switched off before making any adjustments changing accessories or storing the product Such preventive safety measures reduce the risk of starting the product accidentally d Store idle p...

Page 8: ...or should not be connected to a fixed ealectrical installation except by an appropriately licensed person Protect your generator This generator is NOT WEATHERPROOF and should not be exposed to direct sunlight high ambient temperature and damp wet or high humidity conditions Do not smoke while refuelling This is potentially dangerous as it may ignite the fuel and cause an explosion Take care not to...

Page 9: ...the generator to the off position prior to removing the fuel cap and refuelling Not suitable for ethanol fuels Engine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine to obtain more performance Both the output voltage and frequency will be thrown out...

Page 10: ... steel walkway or metal roof Accidental leakage of electrical current could charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface Use of worn damaged or ungrounded extension cords Contact with worn or damaged extension cords could result in electrocution...

Page 11: ...revent use by others Tampering with factory set engine speed settings Engine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine to obtain more performance The output of this generator is electronically controlled and the change to the speed setting wil...

Page 12: ...umes Breathing exhaust fumes will cause serious injury or death Operate generator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away from area of operating unit Risk of unsafe operation Hazard What could happen How to prevent it Operation of generator in c...

Page 13: ...serious injury The generator contains parts which rotate at high speed during operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught by moving parts Risk from lifting Hazard What could happen How to prevent it Lifting a very heavy object Serious injury can ...

Page 14: ...Muffler 11 Exhaust spark arrestor 12 AC sockets X3 13 Master 240Va c switch 14 Control panel 15 Oil Filler cap dipstick 16 Oil drain plug 17 Ground frame terminal 18 Recoil starter 19 Choke lever 20 Air filter cover 21 Air Filter 22 Spark plug lead cover 23 Spark Plug 24 Tap outlet 25 Fuel tap sediment cap 26 Fuel tap lever 27 Fuel tank inlet filter 28 Feet x4 29 Wheel x2 30 10mm Tube Spanner 31 2...

Page 15: ...ORT toll free 3500W Digital Inverter with Pure Sine Wave e mail help powertoolsupport com 1800 909 909 MODEL INF3800A 03 2016 52299 13 Parts List 27 34 29 30 31 32 33 23 22 2 1 5 3 6 5 17 12 13 15 29 16 28 28 25 26 24 ...

Page 16: ...rTVs heating lighting applications and small to medium fridges NOTE Maintain normal safety precautions with appliances and accessories as for use on normal reticulated mains supply Operating Periods NOTE This product is for domestic DIY use only Maximum daily operational use should not exceed 10 hours a day It is not recommended to continually use the generator day after day APPLIANCE Caravan Air ...

Page 17: ...nerator within red markers Fig A 1 Place the generator on a flat and level surface and then raise one side of the generator by placing a wooden block or something similar underneath the frame Fig B so the generator is slightly raised and allows you access to be able to add the feet 28 WARNING Do not turn the generator upside down or place the generator on its side Ensure the generator is stable an...

Page 18: ...surface on the four rubber feet 28 PortableWheeledType Generator Assembly This generator is supplied with 2 wheels to assist with transportation which require the following assembly 1 Remove the cover of the wheel by holding one of the spokes of the outside cover on the wheel and pulling towards you until the cover disengages and can be removed 2 Insert the bolt through the outside of the wheel th...

Page 19: ... hex head screw into the large boss on the base frame cross member on the handle end of the generator Fig I Tighten firmly Assembly of the Folding Carry Handle This generator is supplied with a folding carry handle 6 to assist with transportation when wheeling the generator around on the wheels 1 Align the holes on each bracket of the carry handle with the holes on each side of the generator frame...

Page 20: ...d to add oil for the generator to operate 2 Load Status indicator Fig M The red load status indicator light 8 advises the operator that a fault has been detected and the power supply to the control panel has been interrupted When the red load status indicator is operating red there is NO 240Va c available to the control panel When the engine is running the load status indicator light 8 flashes und...

Page 21: ...ckets 12 In an overload condition there is no 240Va c available to the panel so the green indicator will not operate Preparing the Generator It is important to check the generator before you commence operating the unit IMPORTANT Ensure that the engine has oil When leaving the factory this generator has NO OIL in the engine NOTE The engine will not start if the generator has no oil Checking the Eng...

Page 22: ...ng fuel 4 To add fuel pour the unleaded fuel from an approved fuel container into the fuel tank 1 As fuel expands DO NOT FILL to the lip of the tank Maximum fill is to the top of the fuel tank inlet filter 27 rim 5 Replace fuel tank cap 2 turning in a clockwise direction to lock Checking the Engine Oil The engine of this generator is NOT filled with oil when unpacked Prior to starting the engine e...

Page 23: ...dipstick 15 by the above method Do NOT over fill Engine oil replacement 1 Place the generator on a flat and level surface and warm up the engine for several minutes Then stop the engine 2 Place an oil pan under the generator and commence removing the oil drain plug 16 by using a 10mm socket not supplied and rotating in an anti clockwise direction to remove so that the oil can be completely drained...

Page 24: ... the engine is already warm NOTE The direction for the choke is also indicated below the choke lever 19 on the air filter cover 20 4 Press the petrol motor On Off switch 4 to the On position as indicated by an I Fig U NOTE When the engine is started for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the engine Slowly pull the recoil s...

Page 25: ...or approx 30 seconds 3 Press the On Off switch 4 to the Off position as indicated by an O Fig U 4 Turn the fuel lever tap 26 anti clockwise to the off position Fig V Failure of the motor On Off Switch In the unusual event the motor On Off switch 4 does not stop the petrol motor of the generator follow the following procedure to shut down the generator 1 Turn off the master 240Va c switch 13 Fig R ...

Page 26: ...200w 1760w Anglegrinder 2000w TV 200w CaravanFridge 200w 2400w Hairdryer 1600w caravanfridge 200w laptop 250w 2050w Connecting apparatus to the Generator Start the generator and allow the generator to run for a few minutes to warm up Check the green LED power supply indicator 9 is glowing green Check the total rating of the appliance s to be connected and ensure the rating of the appliance s does ...

Page 27: ...ated on the appliances rating label will show rated wattages and does not include start up power Overload condition If the AC side of the generator is overloaded the red load status indicator 8 LED will illuminate The generator will continue to supply 240V output for a short time but if the load is not reduced the 240V supply will be automatically shut down For details on the various conditions of...

Page 28: ... Clean Replace if necessary Fuel filter Clean fuel drain filter Replace if necessary Valve clearance Check and adjust when engine is cold Fuel line Check fuel hose for crack or damage Replace if necessary Exhaust system Check for leakage Retighten or replace gasket if necessary Check muffler screen Clean replace if necessary Carburettor Check choke operation Starting system Check On Off switch ign...

Page 29: ...ots and could possibly damage the rotor stator and the internal windings of the generator head Storage Never store generator with fuel in the tank indoors or in enclosed poorly ventilated areas where fumes can reach an open flame spark or pilot light as on a furnace water heater clothes dryer or other gas appliances Ensure the fuel tank and carburettor are BOTH fully drained of fuel Open the fuel ...

Page 30: ...f the spark plug 23 and then remove spark plug 23 from the generator using the supplied 21mm Spark PlugTube Spanner 31 by rotating in a clockwise direction FigY 2 Remove carbon deposits using a wire brush 3 Check for discoloration on the top of the spark plug 23 The standard colour should be a tan colour 4 Check the spark plug gap The acceptable gap should be between 0 6 0 8mm Fig Z 5 The recommen...

Page 31: ...r 30 by removing unscrewing the two screws on the face of the cover in an anti clockwise direction Fig AA 2 Remove the air filter 21 Fig AB 3 Wash the air filter 21 in hot soapy water and allow to dry 4 Lubricate the air filter 21 using engine oil SAE 10W 30 5 Thoroughly squeeze the air filter 21 removing any excess oil 6 Replace the air filter 21 7 Secure the air filter cover 20 back on to the si...

Page 32: ...position Fig AC 3 The fuel tank inlet filter 27 is located directly under the fuel tank cap 2 and protects impurities entering the fuel tank 1 during refuelling Remove the fuel tank cap 2 by turning in an anti clockwise direction Fig AD 4 Remove the fuel tank inlet filter 27 Fig AE and wash thoroughly in petrol 5 Re assemble by putting the fuel tank inlet filter 27 back and then securing the fuel ...

Page 33: ... 26 Fig AF Be careful not to move the tap housing Do not lose the small seal on the thread of the sediment cap 3 The filter inside the sediment cup can be cleaned in petrol to remove any build up of dirt on the outside of the filter Do not operate the generator without this filter in place 4 After cleaning the filter replace the seal then the filter on top of the sediment cap and then insert the a...

Page 34: ...ent to ensure acceptable internal cleanliness 5 Wear eye protection when carrying out cleaning Warranty Your new Gardenline Generator will more than satisfy your expectations It has been manufactured under stringent Gardenline Quality Standards to meet superior performance criteria You will find your new Generator easy and safe to operate and with proper care it will give you many years of dependa...

Page 35: ...r the course of the first 3 years after the date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event of such an occurrence or if you require any information about the product please contact us via our after sales support services details of which can be found in this manual and on the product itself After Sales Support TEL 1...

Page 36: ...9 in wrong position 4 Adjust choke lever 19 accordingly Refer to page 22 5 Fuel shut off valve in closed position 5 Open fuel shut off valve 6 Unit loaded during start up 6 Remove load from unit 7 Spark plug 23 wire loose 7 Attach wire to spark plug 23 8 Old fuel in carburetor 8 Fuel will deteriorate in the carburetor fuel bowl very quickly Open the drain screw in the bowl of the carburetor until ...

Page 37: ...oximate Generator Run time Hours per full tank Full Load 5 5 Hours 50 Load 9 Hours 25 Load 12 Hours Fuel tank capacity 10 5L Fuel type Unleaded Oil tank capacity 600ml Oil type 4 Stroke SAE 10W 30 Net weight 31kg with wheels and handle Spark plug NGK BPR6ES Product Dimensions without wheels or carry handle 52cm x 41cm x 46cm L x W x H 10 Noise rating 69 dB A taken at 7 5 metres You must wear ear p...

Page 38: ...d products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales support by calling the supplier s Customer Service Hotline Made in China Gardenline is a registered trademark of ALDI Stores DIS...

Reviews: