background image

AE180H

100-Channel

Programmable

Twin Turbo

Hand-Held

Sports

Scanner

OPERATING GUIDE

1

Y:...UB302BH(AE180H).vp

Tue Jul 08 16:22:31 2003

Color profile: Disabled

Composite  Default screen

Summary of Contents for AE180H

Page 1: ...AE180H 100 Channel Programmable Twin Turbo Hand Held Sports Scanner OPERATING GUIDE 1 Y UB302BH AE180H vp Tue Jul 08 16 22 31 2003 Color profile Disabled Composite Default screen...

Page 2: ...g damage if the Volume suddenly becomes too loud because of the Volume Control or Squelch Control setting This may be particularly true of the type of earphone that is placed in the ear canal n NICKEL...

Page 3: ...iii 3 Y UB302BH AE180H vp Tue Jul 08 16 22 38 2003 Color profile Disabled Composite Default screen...

Page 4: ...red Frequency 15 Programming SEARCH 15 Programming Channels with Alpha Characters 16 Alert Beep Setting 17 Scanning 18 Bank Scanning 18 Priority Scan 19 Delay 19 Locking Out Channels 20 Looking for Lo...

Page 5: ...the scanning cycle resumes until another transmission is received Or you can select an optional Delay so the scanner stays on the channel for 2 more seconds after the transmission stops waiting for an...

Page 6: ...916 12 5 8 33 selectable AM Aircraft 137 0000 143 9950 5 FM Military Land Mobile 144 0000 145 9875 12 5 FM 2 Meter Amateur Band 146 0000 155 9900 10 FM VHF High Band 156 0000 162 0250 12 5 FM VHF Mari...

Page 7: ...C Adapter Charger AD 235 n Earphone n Belt Clip with 2 Screws n Battery BP 180 n This Operating Guide n Nickel Cadmium Battery Disposal Notice Please read this Operating Guide thoroughly before operat...

Page 8: ...riority Channels You can assign one Priority Channel in each Bank Assigning priority channels allows you to keep track of activity on your most important channel s while monitoring other channels for...

Page 9: ...Overview section for adjustment procedures ON OFF VOLUME Control Use this control to turn the scanner on or off and to adjust the volume VFO Control Use this control to select channels in Manual mode...

Page 10: ...e Function Indicators Only the active mode s function s are displayed during operation SCAN Indicates SCAN Mode SEARCH Indicates SEARCH Mode Flashes when in TURBO SEARCH Mode PRIORITY Indicates PRIORI...

Page 11: ...6 51 60 7 61 70 8 71 80 9 81 90 10 91 100 5 Press BAND to start Limit search Press and hold BAND to select the band for band search Then press BAND again to start band search 6 Press to stop Band serc...

Page 12: ...on press and hold ATT 13 Press to turn ON or OFF the automatic 2 second delay during scanning or searching for active frequencies When delay is activated DELAY appears on the display In this mode when...

Page 13: ...Plug the AC Adapter Charger AD 235 into the Charging Jack located on the left side of the AE180H You can use the scanner while it is charging WARNING Use only the supplied AC Adapter Charger Any othe...

Page 14: ...ne or a stereo headset of the proper impedance 32W The output of this jack is monaural audio but you will hear it in both headphones of a stereo headset IMPORTANT Be sure to use only the supplied earp...

Page 15: ...ockwise from the threshold point a much stronger signal is required to open the squelch If squelch is set on a point clockwise from the threshold you will hear a constant sound noise if no signal is p...

Page 16: ...gram frequency range you can search within the frequency range When an active frequency is found the scanner stops on that frequency as long as the transmission lasts If the Delay Function is on the s...

Page 17: ...rogramming By Manual Entry 1 Select a frequency from the appropriate Frequency Directory Example Program 125 2500 MHz into Channel 18 2 Make sure the scanner is in the SCAN Mode If it is in the SEARCH...

Page 18: ...r the correct frequency 9 To program another channel repeat the above procedures Deleting a Stored Frequency To delete a frequency from a channel 1 Display the channel and frequency that is to be dele...

Page 19: ...uency into another channel a Select the channel number with the numeric keys and press The selected channel will appear on the display The frequency currently stored in the channel will appear for 2 s...

Page 20: ...you want to program 7 When you complete the input press The words you have programmed flash twice Alert Beep Setting When a transmission occurs on a channel on which you have set the Alert Beep funct...

Page 21: ...ll not be scanned This procedure helps to speed up the scanning cycle Note One Bank must always be active You cannot deactivate all 10 banks at the same time If you try to deactivate all 10 Banks Bank...

Page 22: ...pear on the display to the left of the new channel number That channel will now be the Priority Channel for that Bank The P will no longer appear for the previous Priority Channel To activate Priority...

Page 23: ...You can lock out any or all of the Priority Channels in the same way as other channels If you lock out all Priority Channels you will see this message You can also remove L O from all Locked Out chan...

Page 24: ...the Search Speed to 300 steps per second in those bands that have 5 kHz steps See the table on page 3 for the Band Chart When you activate TURBO SEARCH the SEARCH indicator flashes Press TURBO again t...

Page 25: ...equency step and turn the VFO control counter clockwise to move down the frequency step 3 When you wish to store frequency or change the channel you need not press first Search Skip Frequency The scan...

Page 26: ...of the case You may need to exert slight pressure toward the top of the scanner as you slide the Battery Pack out of the case 5 Carefully plug in the new Battery Pack observing the proper polarity The...

Page 27: ...on n Do not use the scanner in high moisture environments such as the kitchen or bathroom n Avoid placing the unit in direct sunlight or near heating elements or vents n Do not plug the scanner into a...

Page 28: ...Use only the AC Adapter Charger that came with your scanner Do not leave the AC Adapter Charger plugged in for long periods Avoid placing the scanner in direct sunlight or near heating elements or ven...

Page 29: ...396 Earphone EP 009 AC Adapter Charger AD 235 Straight Cigarette Lighter Power Cord fused UA 502 Coiled Cigarette Lighter Power Cord fused UA 502A Belt Clip with 2 screws BCK 150 AE180H Operating Gui...

Page 30: ...n a fringe area Reposition the scanner Scan won t stop Adjust the Squelch Control Check the antenna connection It is possible that none of the programmed frequencies are active at the time Try Band Se...

Page 31: ...5 8 162 0300 173 9900 FM 10 9 406 0000 439 9875 FM 12 5 10 440 0000 449 9875 FM 12 5 11 450 0000 469 9900 FM 10 12 470 0000 512 0000 FM 12 5 13 806 0000 960 0000 FM 12 5 Scan Rate 100 channels per se...

Page 32: ...belt clip Weight 0 71 lb 320 g Power Requirements 4 8V DC internal battery or AC Adapter Charger Features specifications and availability of optional accessories are all subject to change without not...

Page 33: ...our sole responsibility that this equipment Albrecht Sportscan AE180H is in compliance with the essential requirements and other relevant provisions of the EMC R TTE and LVD Council Directive of the...

Page 34: ...MEMO 31 35 Y UB302BH AE180H vp Tue Jul 08 16 25 42 2003 Color profile Disabled Composite Default screen...

Page 35: ...MEMO 32 36 Y UB302BH AE180H vp Tue Jul 08 16 25 42 2003 Color profile Disabled Composite Default screen...

Page 36: ...All rights reserved UBZZ01302BZ Printed in China 37 Y UB302BH AE180H vp Tue Jul 08 16 25 45 2003 Color profile Disabled Composite Default screen...

Reviews: