Page 2: ...rning the product was purchased from qualified Akces MED Ltd employee Product marked with the CE sign is Class I medical device of rule 1 consistent with the requirements of Regulation EU 2017 745 of...

Page 3: ...5 Feet adjustment 5 2 Knee supports adjustment 5 2 1 Knee supports height adjustment 5 2 2 Knee supports depth adjustment 5 3 Pelvic chest belt adjustment 5 3 2 Adjustment of the width of the pelvic...

Page 4: ...ction so that the femoral head can be properly positioned in the acetabulum This prevents hip dysplasia and ensures correct joint alignment in the frontal plane during upright standing Rotating knee s...

Page 5: ...ing position on their own as a result of prolonged immobilization The device is an irreplaceable aid in the rehabilitation process both in terms of movement and social integration It is great help in...

Page 6: ...e joint may not be able to use the standing frame Make sure that the position of the user in the standing frame does not cause excessive pressure or stretching of affected areas of the body In such ca...

Page 7: ...uction function 4 Pelvic belt with pelvic rotation function 6 Tray 5 Chest belt with independent adjustment of chest rotation 3 Independently adjustable knee supports 5 2 6 1 4 3 5 3 GENERAL CHARACTER...

Page 8: ...ht cm 80 7 weight kg 18 5 Note Measurement tolerance range is 1 cm in indicative user height cm 80 120 A W Height cannot be the main parameter while choosing the product size Note Approximate values d...

Page 9: ...easier to set the desired height To adjust the height of the standing frame use the knobs located on the column of the standing frame 3 Tighten the knobs Please note that when you change the height of...

Page 10: ...two height adjustment knobs for one knee support the knobs are on the front side and for the other knee support the knobs are on the side of the column 3 4 5 2 2 KNEE SUPPORTS DEPTH ADJUSTMENT 5 6 The...

Page 11: ...sted with one knob for each support fig 7 7 5 3 PELVIC CHEST BELT ADJUSTMENT 8 9 5 3 1 ADJUSTMENT OF THE HEIGHT OF THE PELVIC CHEST BELT The height of the pelvic chest belt is adjusted with one knob f...

Page 12: ...nding frame The width adjustment is also done with the use of Velcro straps placed on the belts 11 5 3 3 ADJUSTMENT OF THE DEPTH AND ROTATION OF THE PELVIC CHEST BELT 12 The belts are additionally sec...

Page 13: ...to the user s needs 14 5 5 FEET ADJUSTMENT 15 5 5 1 FEET SPACING ADJUSTMENT Each feet stabilizer is blocked with two knobs By loosening the knobs you can set the user s feet in the proper position inc...

Page 14: ...T AND ROTATION Each feet stabilizer has a front back and rotation adjustment Make sure to tighten the knobs properly The adjustment is possible after loosening the knobs located under the stabilizers...

Page 15: ...rains bags catheters etc if applied have to be secured to function properly and not to disturb during using the product if it is necessary for a patient to wear orthopedic supply collar corset orthesi...

Page 16: ...the chest and pelvic belts in order to place the user in the standing frame adjust the standing frame to the user s size and needs 1 How to prepare the standing frame for use assemble the standing fra...

Page 17: ...ting body deformities overloading joints It is highly advisable to adjust the device before every use of a standing frame This adjustment has to be done only by a trained person or therapist If any of...

Page 18: ...user s measurements and needs e g the adjustment of pelottes etc make sure that there are no damages or different faults which could endanger user s life check if all parts are working and are correc...

Page 19: ...g transportation 8 It is important to engage brake during getting into and getting out the standing frame 12 Before using the standing frame remove all paper and plastic packaging The packaging is not...

Page 20: ...lting from the extended warranty are regulated by the warranty card All defects which appear after warranty period can be repaired only when the user will pay for it This rule doesn t apply to refunde...

Page 21: ...aving read the recommendations of the manufacturer of the given cleaner 11 It is possible to disinfect metal plastic wooden and upholstery elements of the product with a generally available disinfecta...

Page 22: ...if standing frame construction is free of breaks or any kinds of deformities check if belts are not frayed check if buckles and clamps work correctly clean wheels Before using it is necessary to check...

Page 23: ...operly mounted if applicable if the adjustment mechanisms of the following elements work properly if applicable headrest backrest seat abduction block armrests footrests Check all the mechanisms of th...

Page 24: ...or or the Manufacturer If the tire pressure is too low in ate them to the correct level Once a month Once every 6 months Construction moving parts In case of any damage or defects discontinue the use...

Page 25: ...ht Do not chlorinate Do not iron Do not bleach Do not dry in a drum dryer Careful Delicate content Dry vertically Relative humidity storage Storage temperature limitation You need to use the tools ind...

Page 26: ...ed Dealer Date of issue 19 07 2021 The last update 19 07 2021 S awomirWro ski 2021 MANUFACTURER Jasionka 955B 36 002 Jasionka Poland ph 48 17 864 04 70 e mail export akces med com Akces MED Ltd BDO 00...