INSTRUCTION MANUAL

SeQual

®

 Regalia

PSA Oxygen Concentrator System

Summary of Contents for SeQual Regalia

Page 1: ...INSTRUCTION MANUAL SeQual Regalia PSA Oxygen Concentrator System ...

Page 2: ...ENTRATOR 13 3 0 Installation 3 1 GENERAL 15 4 0 Power Management Feature 4 1 IN THE EVENT OF A POWER INTERRUPTION 17 5 0 Operating Conditions 5 1 CONTROL PANEL DISPLAY 19 5 2 DISPLAY OF OPERATING CONDITIONS 20 5 3 NON USAGE 20 6 0 Maintenance 6 1 ROUTINE MAINTENANCE 21 6 2 CABINET AND POWER CORD 21 6 3 AIR INLET FILTER 21 6 4 OXYGEN DELIVERY ACCESSORIES 21 6 5 TROUBLESHOOTING CHARTS 22 7 0 Technic...

Page 3: ...7 3 TECHNICAL SUPPORT 26 ...

Page 4: ......

Page 5: ... Tables Table 2 1 Regalia Operating Environment Guidelines 11 Table 5 2 Display of Operating Conditions 20 Table 6 3 Concentrator is NOT Running 22 Table 6 4 Concentrator is Running 23 Table 7 5 Regalia Specifications 25 ...

Page 6: ...be taken to reduce the risk of fire Materials that burn in air and even some material that will not burn in air are easily ignited and burn rapidly in high concentrations of oxygen For safety concerns all possible sources of ignition must be kept away from the oxygen concentrator and preferably out of the room in which it is being used Smoking in the proximity of an operating oxygen concentrator i...

Page 7: ...y Type BF Equipment F type applied part complying with the specified requirements of IEC 60601 1 to provide a higher degree of protection against electrical shock than provided by type B applied part Class II Equipment Equipment in which protection against electrical shock does not rely on basic insulation only but in which additional safety precautions are provided A Amperes Note Provides informa...

Page 8: ......

Page 9: ...serve as a reference as you use your oxygen concentrator 1 2 CAUTIONS WARNINGS AND HAZARDS Warning and Caution notices used in this manual apply to hazards or unsafe practices that could result in personal injury or property damage Not for medical purposes Keep oxygen concentrator and cord away from hot surfaces Do NOT use the oxygen concentrator if it has a damaged cord or plug contact qualified ...

Page 10: ...nel Warning An alternate source of supplemental oxygen is recommended in the event of a power outage alarm condition or mechanical failure Patents Trademarks and Copyright The Oxygen Concentrator System is protected by the following US Patents 4 925 464 5 112 367 5 114 441 5 268 021 5 366 541 5 593 478 5 730 778 Re 35 099 Other patents pending ...

Page 11: ...ature 50º F to 104º F 10º C to 40º C Electrical Use no extension cords or electrical outlets controlled by a switch Placement No closer than 3 inches 7 6 cm from the wall draperies and furniture Environment Smoke pollutant and fume free Relative Humidity 10 95 Operating Time Up to 24 hours per day Flow Rate From 0 5 LPM to 10 0 LPM Table 2 1 Regalia Operating Environment Guidelines For rated perfo...

Page 12: ... or heat register 2 4 BEFORE OPERATING YOUR OXYGEN CONCENTRATOR There are many different types of oxygen tubing that can be used with this oxygen concentrator Oxygen Tubing Connect the oxygen tubing directly to the oxygen outlet port Connect the other end of the tube to the application if not already attached The tube fitting may be tight Do NOT use oil or grease to lubricate To ensure there is en...

Page 13: ...presentative General Precautions Retain the product s safety and operating instructions for future reference Follow all operating and usage instructions Observe all warnings on the product and in the operating instructions To reduce the risk of fire bodily injuries and damage to the oxygen concentrator observe all safety precautions Do NOT connect to an extension cord or electrical outlet controll...

Page 14: ......

Page 15: ...ion of this manual Always check to see if the inlet air filter is clean 3 ON OFF Button Insert the plug into the electrical wall outlet Push the On Off button the green light will illuminate to indicate the unit is running 4 Warm up Period After initially turning on the unit allow three 3 to ten 10 minutes for the unit to reach its specified performance If the unit is equipped with an oxygen conce...

Page 16: ... power interruption the unit may automatically reduce the flow rate briefly before returning to the set flow rate 5 Flow Rate Adjustment Adjust the flow rate to desired setting Press the Plus button to increase or the Minus button to decrease the flow rate until the proper level is displayed ...

Page 17: ...not operating The Regalia should be located where the alarms can be seen and heard If the duration of the interruption is shorter than twenty seconds and the unit has not been turned off the Regalia will resume operation twenty seconds after the initial interruption During the power interruption The user can press the ON OFF button to silence the alarms and turn the unit off If the unit was not tu...

Page 18: ......

Page 19: ...rator is an OM Model equipped with an oxygen monitor the oxygen concentration is being continuously monitored while the Regalia is running and oxygen is being produced If the concentration level falls below preset levels an indicator light will activate Operating conditions are described in the table on the following page ...

Page 20: ...On Quickly Yes Off Flashing Off Off Running Oxygen Concentration Below Normal Level Yes Off Off Flashing On Running Oxygen Concentration Abnormal Level 1 Yes Off On Off Off Running Button Stuck Yes On On Off Off Running 9V Battery Low Voltage if enabled No Off Off Flashing On Not Running Unit is overheating Compressor Malfunction Power Interruption Internal Fuse Blown No On Off On Off On On Runnin...

Page 21: ...abinet Cleaning the air inlet filter is the most important activity you will perform to keep your oxygen concentrator performing properly Check this air filter daily and clean it at least once per week 1 Remove the filter from the cabinet 2 Wash the filter in warm water using a mild detergent solution 3 Rinse the filter thoroughly and squeeze out the excess water 4 Allow the filter to air dry The ...

Page 22: ...cord pulled from wall outlet Plug in power cord Power outage Push On Off Button to turn off unit Push On Off Button to restart unit when power comes back on No power at wall outlet Ensure the unit is not plugged into a wall switched outlet Check house circuit breaker or fuse reset or replace as needed Audible Alarm Blinking Red Light Flow Indicator Blank Back Light On Unit overheating Remove any o...

Page 23: ...se Solution Low oxygen flow see alarm indications in Display of Operating Conditions table Restriction in tubing Repair or replace as required Air Inlet Filter restricted Clean air inlet filter Internal component worn or malfunctioning Service required Yellow Light On Button is stuck Service required Flow Rate not visible on Flow Indicator Display LCD malfunction Service required Audible Alarm Red...

Page 24: ......

Page 25: ... Yellow Light Flashing Below Normal Operation 85 Red Light Flashing Abnormal Operation 70 Audible Alarm Indicators Power Interruption Power Surge simulated circuit breaker Compressor Malfunction Excessive Internal Temperature Outlet Pressure 35 36 psig 241 2 248 1 kPa relief valve Low Oxygen Output 70 oxygen Back up Alarm Power 9V Battery Filters Cabinet Air Inlet Compressor Inlet and HEPA Back pr...

Page 26: ... order replacement parts contact the AirSep Commercial Products Service Department by telephone In the USA or Canada call 1 800 320 0303 Outside the USA or Canada call 716 691 0202 Send fax inquiries anytime to 716 564 2717 Address written inquiries to AirSep Corporation 260 Creekside Drive Buffalo NY 14228 2075 USA Attention Commercial Products Service Department E mail info airsep com Visit www ...

Page 27: ......

Page 28: ...ty descriptions specifications and or processes to its products at any time without prior notice and with no further obligation or consequence Any rights expressly stated herein are reserved by us as applicable AirSep Corporation 260 Creekside Drive Buffalo NY 14228 2075 U S A Tel 716 691 0202 Fax 716 691 1255 info airsep com www airsepcpd com MADE IN USA ...