background image

INTERNAL-TELEPHONE SYSTEM

TC-M Series

TC-10M:

10-call master

TC-20M:

20-call master

Models:

INSTALLATION & OPERATION MANUAL

PRECAUTIONS ON INSTALLATION & WIRING

GENERAL PRECAUTIONS 

DISMANTLE
PROHIBITIONS

GENERAL PROHIBITIONS

Examples of Symbols;

This Manual and the Markings on the product contain various 
symbols in order that the product can be used safely and properly, 
and that the installer and user are protected from injury and 
property damage. The following precautions must be thoroughly
 read and understood before proceeding.

TC-20M

The        mark indicates caution 
statement (incl. danger and warning), 
which is specifically shown inside. 

 

All the products of other manufacturers, power supply, buzzer, etc. used for TC-M, are not within our warranty, 

    and must be used under manufacturer or distributor's specifications and warranty.

The       mark indicates contents 
which demands a specific 
action shown inside or attached.

The       mark indicates contents 
which prohibit a specific action 
shown inside or attached.

MOISTURE
PROHIBITIONS

1. TC-M equipment is designed for indoor use only.
    Do not install outdoors.
2. TC-M system is not operational during a power failure.
3. In areas where broadcasting station antennas are close by, 
    intercom system may be affected by radio frequency interference.
4. Keep all DC wiring at least 30cm, 1' away from AC 100~240V 
    wiring, fluorescent lighting, or dimmer switches.
    Otherwise, cross AC wiring at a 90

°

 angle.

 Weather conditions, such as lightning storms, may cause damage 

    to TC-M equipment.  It is suggested to take protective measures 
    as follows;
    • When an AC transformer is used

    • When a DC power supply is used:
      On the power supply with grounding terminal, be sure to take the 
      terminal to earth ground.
      In this case, it is not necessary to connect a surge-arrester.

    When using a power supply that has no grounding terminal, 
    install a surge-arrester in the same manner as stated above. 
    Surge-arrester SA-1 is available from Aiphone.

  1. Do not connect any power source other than specified on 
      TC-M master.  Fire or damage to the unit could result.
  2. Do not open TC-M master.  High voltage is present inside, 
      and it can cause electric shock. 
  3. Do not change or alter TC-M master.  It can cause fire 
      or electric shock.
  4. Make sure wires are connected properly before plugging in 
      power supply.
  5. Keep TC-M master away from water or any other liquid. 
      Fire or electric shock could result.
  6. Keep AC plug away from moisture or dust.
  7. Keep AC cord away from being marred or crushed. 
  8. Do not plug or unplug with wet hands.
  9. Do not put any metal into TC-M through openings.
      It can cause fire, electric shock or unit damage.

    - 

Places subject to moisture or humidity extremes.

    - 

Places subject to environmental conditions

,

    such as oil, dust, chemicals, salt, etc.
    - 

Places subject to constant vibration or impact.

    - 

Places where noise generating devices such as 

   TV or radio are close by.

WARNING

Negligence could result in death or serious injury.

CAUTION

Negligence could result in injury or damage to property.

WARNING

CAUTION

1. Do not make call tone testing with hook switch manually held down.
    The call tone sounds very loud near your ears, and can cause 
    your hearing damage.
2. Do not install or make any wire terminations while power supply 
    is plugged in. It can cause electrical shock or damage to the unit.
3. Install TC-M master in a convenient location, but not 
    where it could be bumped or jarred.
4. In case of electrical storms, unplug power supply from AC outlet.
    It can cause fire, electric shock, or power surge damage.
5. Do not install TC-M components in any of the following locations, 
    as it may cause the system to malfunction;

    - 

High or extreme cold temperature area:

    under direct sunlight, near equipment that varies in temperature, 
    in front of air conditioner, inside a refrigerated area, etc.

GENERAL PRECAUTIONS

GENERAL INSTRUCTIONS

TC-10M

AC trans.

TC-10M   TC-20M

AC 15 – 16V
or DC 18V

Surge-
arrester

Install a surge-arrester
(discharging voltage: 

100~180V

)

at a point close to the output,
taken to earth ground.

Grounded

– 1 –

83945900 0102 A

A

Содержание Tc-10m

Страница 1: ...r SA 1 is available from Aiphone 1 Do not connect any power source other than specified on TC M master Fire or damage to the unit could result 2 Do not open TC M master High voltage is present inside...

Страница 2: ...g relay TAR 3 IF DA TC 10M TC 20M TC 20G TC 40G TB SE TB SE R IER 2 TAR 3 TB AD1 TB AD10 IF DA PS 18C PS 18E 10 call master 20 call master 20 call add on selector 40 call add on selector Handset sub s...

Страница 3: ...ide of master Features TC 20G or TC 40G add on selector connects additional TB SE subs allowing system expansion One or dual master configuration TB AD1 adaptor connects TC M with an IE IF Series audi...

Страница 4: ...om TB SE terminal 2 2 wires from TB SE subs must not be made common at any other point than on the TC M terminal block 1 12V 2 3 4 5 6 7 8 9 10 E E E E E E C M R R T T S S 1 12V 2 3 4 5 6 7 8 9 10 E E...

Страница 5: ...sub s station number numbered from the top on each 10 button row 2 parallel wires per TB SE sub nonpolarized Be sure to run each pair of wires directly to TC M master E line in each pair should not be...

Страница 6: ...3 1 2 E 4 1 2 E 5 1 2 E 6 1 2 E 7 1 2 8 1 2 E 9 1 2 10 1 2 TB SE Sub station TC 10M Master station S S Connector To power supply Do not connect any power source here IN AC 15 16V or DC18V 12V OUT Desi...

Страница 7: ...D6 1 2 E D7 1 2 D8 1 2 E D9 1 2 D10 1 2 IF DA E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 1 2 1 2 3 4 5 6 7 8 9 10 12V T R S S To power supply Do not connect any power source here IN AC 15 16V or...

Страница 8: ...larized To power supply Do not connect any power source Designate any terminal for TB AD1 Call extension IER 2 1 E Call extension IER 2 1 E Common TB SE sub rings two TC M Masters Each master can call...

Страница 9: ...zer is activated and on TB SE sub call tone sounds at reduced volume TAR 3 relay activates an AC operated buzzer AC 240V 0 3A DC operated buzzer must be mechanical type DC 24V 1 0A Do not use DC elect...

Страница 10: ...ll TC M leaves sub A waiting pressing a sub B select button When sub B picks up the call sub A hears a busy tone TC M depresses Transfer switch TC M then reselects waiting sub A with red LED on Three...

Страница 11: ...eive and call tone volume Upper control adjusts handset receiver volume when TC M does not hear a TB SE sub clearly Tone control adjusts ringing tremolo 3 levels TC M dual master system Two masters ca...

Страница 12: ...be responsible for any costs incurred involving on site service calls 8 8 SPECIFICATIONS Power source DC18V 350mA max or AC 15 16V 50 60Hz 750mA max Power consumption 6W max 3W standby Capacity 60 sta...

Отзывы: