9. SPECIFICATION: 

 

MODEL 

Micro PC 300 

Micro PC 600 

Internal UPS

   

(Hi Frequency) 

CAPACITY 

(Computer Load)

 

300VA / 180W 

400VA / 240W 

INPUT 

 

Voltage 

100V/110V/115V/220V/230V/240V 

± 

15%

 

Frequency 

 

50Hz/60Hz 

Auto 

detect

OUTPUT Voltage 

100V/110V/115V/220V/230V/240V

±

5%

 

for Back-up Mode

 

 

Frequency 

50Hz or 60Hz ± 0.1Hz 

 

Wave Form 

Simulated Pseudo Sine Wave 

Runtime of one set of P.C.

(Including 15” LCD monitor)

10 minutes Typical.

 

30 minutes Typical. 

TRANSFER TIME 

4ms Typical. 

BATTERY  

 

 

Maintenance Free

 

 

Lead-Acid 

Ni-MH

Voltage/Capacity 

6V 3Ah x 2pcs 

1.2V 3.5Ah x 15pcs 

Recharge Time 

Approx. 8 hrs to 90% 

Approx. 21 hrs to 90% 

LED/ALARM INDICATION 

Normal/

In charge

 

GRN LED, No Beep. 

Back up / Abnormal Input Voltage 

RED LED Flashing, 2 Beeps / 4 sec.   

Power Saving

 

(When No Load)

 

RED LED Flashing,1 Beep / 4 sec.

 (Auto off in 30 sec.)

 

Low Battery 

RED LED Flashing, 4 Beeps / sec. 

Battery Replacement 

RED LED Flashing, 8 Beeps/ sec.   

Over Load/Fault 

RED LED Flashing, Continuous Beep. 

Abnormal Input Frequency

 

(Back up)

RED LED Flashing, No Beep. 

OPERATION TEMP. 

0-40

 

OPERATION HUMIDITY 

30-95% Non-Condensing 

DIMENSIONS (L*H*W) 

242 x 144 x 40(mm) 

242 x 144 x 40(mm) 

WEIGHT 

(N.W./G.W. KG)

 

3 .5/ 3.5 (kgs) 

3.5 / 4.0 (kgs) 

 
 
 

 

 

U P S 

Uninterruptible Power System

 

User's Manual

 

 

 

 

 

 

INTERNAL TYPE 

(Micro PC series) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Advanced Power Systems GmbH & Co. KG, Bayreuther Str. 6, D-91301 Forchheim 

Phone: +49(0)9191-7005-0, Fax: +49(0)9191-7005-20, www.adpos-ups.de 

 

Micro PC series 

Micro PC series 

 

Summary of Contents for micro PC Series

Page 1: ... 90 LED ALARMINDICATION Normal In charge GRN LED No Beep Backup AbnormalInputVoltage RED LED Flashing 2 Beeps 4 sec Power Saving When No Load RED LED Flashing 1 Beep 4 sec Auto off in 30 sec Low Battery RED LED Flashing 4 Beeps sec Battery Replacement RED LED Flashing 8 Beeps sec Over Load Fault RED LED Flashing Continuous Beep AbnormalInputFrequency Backup RED LED Flashing No Beep OPERATION TEMP ...

Page 2: ...puter interface port is diagramed above for your reference Use Pin4 as the common of Pin2 and Pin5 Pin2 and Pin4 will become close loop from open when the utility is fail Pin5 and Pin4 will become close loop from open when the battery level is low The UPS will shut down when the high level from RS 232 sustained for 3 seconds is applied between Pin6 and Pin7 8 BUTTON FUNCTION ON FRONT PANEL button ...

Page 3: ... for a Pentium III including 15 LCD monitor is about 10 minutes with Micro PC 300 and about 30 minutes with Micro PC 600 2 MAIN FEATURE Microprocessor based design Green power design with auto on off function Suitable for 5 1 4 disk size Protection for overload short circuit Easy installation 3 CAUTION The UPS is suitable for personal computer workstation only and is to be installed inside a compu...

Page 4: ... seconds and stay in normal mode for recharging Please also refer to the LED Alarm Indication in item 7 5 5 3 Push the button for 4sec and check if the UPS can be turned off manually 5 4 Push the button again to turn on the UPS then UPS will enter stand by status and finish the test 6 ERROR MESSAGE OF THE TEST 6 1 During the test if the UPS emits a quick beep it means the battery level is low Plea...

Reviews: