manualshive.com logo in svg
background image

Advance Technologies; Automate the World.

Manual Rev.: 

2.05

Revision Date: 

June 11, 2008

Part Number: 

50-15058-1000

cPCI-3600 Series

3U CompactPCI

®

 Processor Blade with 

AMD Geode™ LX 800 @ 0.9W

User’s Manual

Содержание cPCI-3600 CPU

Страница 1: ...Advance Technologies Automate the World Manual Rev 2 05 Revision Date June 11 2008 Part Number 50 15058 1000 cPCI 3600 Series 3U CompactPCI Processor Blade with AMD Geode LX 800 0 9W User s Manual...

Страница 2: ...rd and face plate layout figures 2 02 2007 10 30 Revised ETX Module VGA support information RTM packaging description and revised BIOS Advanced Chipset Images 2 03 2007 10 31 Technical specification r...

Страница 3: ...e manufacturer be liable for direct indirect spe cial incidental or consequential damages arising out of the use or inability to use the product or documentation even if advised of the possibility of...

Страница 4: ...sociated product s Chapter 1 Introduction Introduces the cPCI 3600 Series provides a general overview its package contents specifica tions features applications and block diagram Chapter 2 Hardware In...

Страница 5: ...operly NOTE NOTE Additional information aids and tips that help users per form tasks CAUTION Information to prevent minor physical injury component damage data loss and or program corruption when try...

Страница 6: ...nion Device Data Book 2004 05 AMD AMD Geode GX Processors Data Book 2004 07 Intel 82551ER Fast Ethernet PCI Controller Data sheet 2 1 Intel 82551QM 3 0 ITE IT8888F PCI to ISA Bridge Chip 0 7 1 Kontron...

Страница 7: ...618 USA ADLINK TECHNOLOGY CO LTD BEIJING Sales Service market adlinkchina com cn Telephone No 86 10 5885 8666 Fax No 86 10 5885 8625 Mailing Address Rm 801 Power Creative E No 1 B D Shang Di East Rd B...

Страница 8: ...India ADLINK TECHNOLOGY JAPAN CORP Sales Service japan adlinktech com Telephone No 81 3 4455 3722 Fax No 81 3 5333 6040 Mailing Address Asahiseimei Hatagaya Bld 1 1 2 Hatagaya Shibuya ku Tokyo Japan A...

Страница 9: ...l Block Diagram 7 2 2 cPCI 3600 CPU ETX Module Layout 8 Pin Out Compatibility 10 2 3 cPCI 3600 Series SBC RTM Connectivity 15 2 4 cPCI 3600 SBC Carrier Board Layout 17 2 5 cPCI 3600 SBC Carrier Connec...

Страница 10: ...in Menu Setup Items 34 3 3 Standard CMOS Features 35 3 4 Advanced BIOS Features 40 3 5 Advanced Chipset Features 43 3 6 Integrated Peripherals 45 3 7 Power Management Setup 48 3 8 PnP PCI Configuratio...

Страница 11: ...CI 3600 Series Block Diagram 7 Figure 2 2 ETX Module Layout Top View 8 Figure 2 3 ETX Module Layout Soldered Side 9 Figure 2 4 Carrier Connector Layout 17 Figure 2 5 Carrier Face plate Layout 24 Figur...

Страница 12: ...cPCI 3600 Series xii List of Figures This page intentionally left blank...

Страница 13: ...ard Connectors Jumpers 18 Table 2 11 CN3 CompactFlash type I II 19 Table 2 12 CN4 44 pin IDE 20 Table 2 13 J1 CompactPCI Pin Assignments 21 Table 2 14 J2 CompactPCI Pin Assignments 22 Table 2 15 JP1 C...

Страница 14: ...xiv List of Tables cPCI 3600 Series This page intentionally left blank...

Страница 15: ...soldered memory support for two 10 100 Ethernet ports a 2 5 IDE HDD and one Compact Flash socket the cPCI 3600 offers both I O versatility and ample storage solutions The module further incorporates a...

Страница 16: ...ion Module Optional and packaged separately NOTE NOTE If any of the items on the contents list are missing or damaged retain the shipping carton and packing mate rial and contact the dealer for inspec...

Страница 17: ...ivity Z 44 pin IDE connector on Board Z CompactFlash slot Z Two USB ports Z Fast LAN port Z Two COM ports Z VGA Port Z PS 2 Keyboard and Mouse port Z LED display Z Reset Button X Form Factor 3U 8HP co...

Страница 18: ...ture X Watchdog Timer 255 level timer generates RESET X VGA integrated in AMD Geode LX 800 CPU companion device Z Supports up to 16 8 million colors 24 bit Z Supports resolution up to 1920 x 1440 Z Su...

Страница 19: ...00BASE TX with TCP UDP IP checksum offloading PXE booting support only for 82551QM version X ETX Board Dimensions 95 mm x 114 mm 3 7 x 4 5 X Weight 72 grams without memory board 74 grams with soldered...

Страница 20: ...Storage X Compliant with CompactPCI Standard PICMG 2 0 Rev 3 0 X Compliant with PCI Local Bus Specification Revision 3 0 X Intel PXE pre boot on Ethernet X Serial Console X EEPROM CMOS Backup X USB B...

Страница 21: ...600 Series 2 Hardware Information This chapter presents detailed cPCI 3600 Series layout informa tion technical drawings pin out settings and jumper settings 2 1 Functional Block Diagram Figure 2 1 cP...

Страница 22: ...e Layout Figure 2 2 ETX Module Layout Top View Table 2 1 ETX Module Layout Top View Description Connector Device Description Connector Device Description A AMD Geode LX 800 Processor D LAN Controller...

Страница 23: ...iption Connector Device Description Connector Device Description A DDR Soldered Memory Optional B BIOS X1 ETX Connector 32 bit PCI bus USB Audio X2 ETX Connector ISA Bus X3 ETX Connector VGA LCD Video...

Страница 24: ...Pin Signal 1 GND 2 GND 3 PCICLK3 4 PCICLK4 5 GND 6 GND 7 PCICLK1 8 PCICLK2 9 REQ3 10 GNT3 11 GNT2 12 3V1 13 REQ2 14 GNT1 15 REQ1 16 3V1 17 GNT0 18 RSV 19 5VCC 20 5VCC 21 SERIRQ 22 REQ0 23 AD0 24 3V1 2...

Страница 25: ...LA22 32 IRQ10 LA23 34 IO16 GND 36 GND SBHE 38 M16 SA0 40 OSC SA1 42 BALE SA2 44 TC SA3 46 DACK2 SA4 48 IRQ3 SA5 50 IRQ4 Pin Signal Pin Signal 51 VCC 52 VCC 53 SA6 54 IRQ5 55 SA7 56 IRQ6 57 SA8 58 IRQ...

Страница 26: ...LCD4 30 LCD7 31 LCD5 32 LCD6 33 GND 34 GND 35 LCD1 36 LCD3 37 LCD0 38 LCD2 39 5VCC 40 5VCC 41 JILI_SDA 42 LTGO0 43 JILI_SCL 44 BLON 45 NC 46 DIGON 47 COMP 48 Y 49 NC 50 C Signal LVDS Signal LCD10 Txo...

Страница 27: ...2 80 INDEX 81 5VCC 82 5VCC 83 RXD1 84 DRV 85 RTS1 86 MOT 87 DTR1 88 WDATA 89 DCD1 90 WGATE 91 DSR1 92 MSCLK 93 CTS1 94 MSDAT 95 TXD1 96 KBCLK 97 RI1 98 KBDAT 99 GND 100 GND Pin Signal Pin 51 LPT FLPY...

Страница 28: ...C 19 OVCR 20 NC 21 EXTSMI 22 I2DAT3 23 SMBCLK3 24 SMBDATA3 25 S_CS3 26 SMBALRT 27 S_CS1 28 NC 29 S_A2 30 P_CS3 31 S_A0 32 P_CS1 33 GND 34 GND 35 PDIAG_S 36 P_A2 37 S_A1 38 P_A0 39 S_INTRQ 40 P_A1 41 B...

Страница 29: ...I 3600 8HP cPCI R3600 8HP Face plate Board Face plate Board Audio Mic In Line Out IDE 44 PIN CF USB 2 0 x 2 Fast LAN COM x 2 Floppy 1 LPT 1 VGA 2 2 PS 2 KB MS LED Reset Button NOTE NOTE 1 Floppy and L...

Страница 30: ...Pin INTA PCI slot interrupt Pin INTB PCI slot interrupt Pin INTC PCI slot interrupt Pin INTD IDSEL cPCI Slot 1 X1_INTAJ X1_INTDJ X1_INTCJ X1_INTBJ AD19 cPCI Slot 2 X1_INTBJ X1_INTAJ X1_INTDJ X1_INTCJ...

Страница 31: ...Hardware Information 17 cPCI 3600 Series 2 4 cPCI 3600 SBC Carrier Board Layout Figure 2 4 Carrier Connector Layout CN1 CN4 CN6 CNX1 JP1 X2 X1 JP2 J1 J2 X3 X4 CN3 JPY1...

Страница 32: ...Description Connector Jumper Description CN1 PS 2 KB MS JP1 Clears CMOS CN3 CF Card Socket JP2 CF Master Slave Switch CN4 IDE Connector JPY1 VGA Front Rear Switch CN6 COM 1 X1 ETX Connector CNX1 COM...

Страница 33: ...2 27 SDD11 SDD4 3 28 SDD12 SDD5 4 29 SDD13 SDD6 5 30 SDD14 SDD7 6 31 SDD15 SDCS 1 7 32 SDCS 3 GND 8 33 GND GND 9 34 SDIOR GND 10 35 SDIOW GND 11 36 5V GND 12 37 IDEIRQ15 5V 13 38 5V GND 14 39 PCSEL GN...

Страница 34: ...DE Data 11 IDE Data 3 11 12 IDE Data 12 IDE Data 2 13 14 IDE Data 13 IDE Data 1 15 16 IDE Data 14 IDE Data 0 17 18 IDE Data 15 Ground 19 20 KEY DREQ0 21 22 GND IDEIOW 23 24 GND IDEIOR 25 26 GND IDEIOR...

Страница 35: ...R C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O 1 STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND...

Страница 36: ...DCK_J2 BRSV 1 DEG GND VGA_G_J2 GND 15 GND VGA_DDDA_J2 GND FAL REQ5 GNT5 GND 14 GND LAN82551_LINK LAN82551_SPEED LAN82551_ACT GND X1_SNDL GND 13 GND X3_SNDR GND V I O 1 P5V_STB P5V_STB GND 12 GND X3_PD...

Страница 37: ...ion X1 PCI Bus USB Audio See section 2 3 2 X2 ISA Bus See section 2 3 3 X3 VGA LCD COM 1 COM 2 LPT IrDA Mouse Keyboard See sections 2 3 4 2 3 5 X4 IDE 1 IDE 2 Ethernet Miscellaneous See section 2 3 6...

Страница 38: ...er Face plate Layout 2 7 cPCI 3600 SBC Carrier Connectors on Face plate Table 2 18 COM 1 COM 2 CN6 CNX1 Pin RS 232 1 DCD Data carrier detect 2 RXD Receive data 3 TXD Transmit data 4 DTR Data terminal...

Страница 39: ...Transmit Data 3 RXDP Receive Data 4 LANCT1 Termination 5 LANCT2 Termination 6 RXDN Receive Data 7 LANCT3 Termination 8 LANCT4 Termination Pin 8 Red Green Yellow Pin 1 Jumper Status Red 1st IDE data t...

Страница 40: ...7 Right Angle Connector Table 2 23 VGA CRT CN2 Connector Pin Signal Name 1 VCC 2 USB 3 USB 4 Ground Signal Name Pin Pin Signal Name Red 1 2 Green Blue 3 4 VCC pull up GND 5 6 GND GND 7 8 GND VCC 9 10...

Страница 41: ...Hardware Information 27 cPCI 3600 Series 2 8 cPCI 3600 RTM Board Layout Figure 2 6 RTM Connector Layout JP1 CNX1 CN5 CN7...

Страница 42: ...28 Hardware Information cPCI 3600 Series Table 2 24 RTM Board Connectors Jumpers Connector Jumper Description Connector Jumper Description CN5 Floppy CNX1 VGA CN7 LPT JP1 FDD LPT Select...

Страница 43: ...round 2 X3_AFD L 3 Ground 4 N C 5 Ground 6 X3_PD5 7 Ground 8 X3_PD0 9 Ground 10 X3_PD6 11 Ground 12 X3_ACK L 13 Ground 14 X3_PD7 15 Ground 16 X3_BUSY L 17 Ground 18 X3_INIT L 19 Ground 20 X3_SLIN L 21...

Страница 44: ...Signal Pin Signal 1 RPSTROBJ 2 X3_AFD L 3 RPP0 4 X3_ERR L 5 RPP1 6 X3_INIT L 7 RPP2 8 X3_SLIN L 9 RPP3 10 Ground 11 RPP4 12 Ground 13 RPP5 14 Ground 15 RPP6 16 Ground 17 RPP7 18 Ground 19 X3_ACK L 20...

Страница 45: ...Hardware Information 31 cPCI 3600 Series 2 10 cPCI 3600 RTM Face plate Layout Figure 2 7 RTM Face plate Layout LAN 2 VGA PRT LINE OUT MIC...

Страница 46: ...M Connectors on Face plate Table 2 28 Audio Port PH 1 PH 2 Connector All other connectors LAN USB 2 0 VGA signals and pin outs are identical to Carrier Face plate specifications Pin RS 232 1 Right Cha...

Страница 47: ...rd BIOS setup program is designed to provide maximum flexibility in configuring the system by offering various selectable options to meet end user requirements This chapter is written to assist you in...

Страница 48: ...agement Setup see section 3 7 Specifies settings for power management PnP PCI Configuration see section 3 8 Specifies settings for PnP PCI Only applicable if your system supports PnP PCI PC Health Sta...

Страница 49: ...week from other date infor mation Time The time format is based on the 24 hour military time clock For example 1 P M is 13 00 00 Press the LEFT arrow key C or appropriate key to move to the desired fi...

Страница 50: ...one Auto Manual Selecting manual allows the user to set the remaining fields on this screen Selects the type of fixed disk User Type will let you select the number of cylinders heads etc Capacity Auto...

Страница 51: ...ry Master item is set to Manual Cylinder Min 0 Max 65535 Sets the number of cylinders for a hard disk Head Min 0 Max 255 Sets the number of read write heads Precomp Min 0 Max 65535 Landing zone Min 0...

Страница 52: ...r enabling the FDD select the correct specifications for the diskette drive X None No diskette drive installed X 360 KB 5 25 inch PC type standard drive X 1 2 MB 5 25 inch AT type high density drive X...

Страница 53: ...ll prompt the user to take any corrective measures X All But Keyboard POST does not stop for a keyboard error but stops for all other errors X All But Diskette POST does not stop for diskette drive er...

Страница 54: ...external cache Hard Disk Boot Priority Allows Hard Disk Boot Device Priority CPU Internal Cache Enables disables CPU internal Cache Quick Power On Self Test Speeds up the Power On Self Test POST If en...

Страница 55: ...ars Sec Sets number of characters that can be typed per second on the keyboard Typematic Delay Msec The time in milliseconds needed before accepting a keystroke on the keyboard Security Option Selects...

Страница 56: ...ts NULL mode connecting two computers to a null modem for direct connection Agent Wait Time min Select the amount of time min to wait for a successful connec tion If the time limit is exceeded the ETX...

Страница 57: ...Options 200 MHz 333 MHz 400 MHz 433 MHz and 500 MHz Memory Frequency Selects the memory frequency Options Auto 200 MHz 266 MHz 333 MHz and 400 MHz CAS Latency When synchronous DRAM is installed the n...

Страница 58: ...of the onboard audio Onboard USB 2 0 Turns on of the onboard USB2 0 CMOS Backup to EEPROM The System BIOS uses CMOS to store user BIOS settings The CMOS Backup to EEPROM saves BIOS settings for use e...

Страница 59: ...E devices that the onboard IDE interface supports Modes 0 through 4 provide suc cessively increased performance In Auto mode the system auto matically determines the best mode for each device Options...

Страница 60: ...P server connection is required for this function Onboard Serial Port 1 2 Selects the address and interrupt for serial ports UART Mode Select Selects the IR Infra Red mode The onboard serial port 2 of...

Страница 61: ...fering other advantages such as support for longer cables However cer tain EPP 1 7 devices can not work properly with an EPP 1 9 port EPP 1 9 is recommended for general use however if there are proble...

Страница 62: ...wer Management menu Standby mode conserves power by turning off the display and the hard drive after a predetermined period of inactivity a time out When the computer exits standby mode it returns to...

Страница 63: ...figures the power button X Instant Off The power button functions as a normal power on off button X Delay 4 Sec The system is turned off if the power button is pressed for more than four seconds IRQ W...

Страница 64: ...First Selects whether to first activate the PCI slot or on chip VGA Reset Configuration Data Resets the Extended System Configuration Data ESCD The default is set to Disabled Enable if system does not...

Страница 65: ...cleared as the BIOS automatically assigns them X IRQ Resources When controlling resources manually assign each system interrupt specifically depending on the type of device PCI or ISA using the inter...

Страница 66: ...PCI 3600 Series 3 9 PC Health Status Current CPU Temp Displays the current CPU temperature Current System Temp Displays the current system temperature CPU VCORE 3 3 V 5 V Displays the actual voltage l...

Страница 67: ...Z Turn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or hi...

Страница 68: ...e serviced by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or does not...

Страница 69: ...nd third party products not manufactured by ADLINK will be covered by the original manufacturers war ranty X For products containing storage devices hard drives flash cards etc please back up your dat...

Страница 70: ...emi cals X Damage caused by leakage of battery fluid during or after change of batteries by customer user X Damage from improper repair by unauthorized technicians X Products with altered and or damag...

Отзывы: