background image

User Instructions

ENCORE BURST 100 IP

Summary of Contents for ENCORE BURST 100 IP

Page 1: ...User Instructions ENCORE BURST 100 IP ...

Page 2: ...DMX Channel Modes Notes 02 21 19 1 1 1 1 2 3 4 Initial Release FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC RADIO FREQUENCY INTERFERENCE WARNINGS INSTRUCTIONS T...

Page 3: ...res I Warranty Registration Safety Guidelines IP Notice Installation Overview DMX Set Up DMX Addressing DMX Modes System Menu Operating Instructions Multiple Unit Power Linking I Dimmer Curve Chart Dimensional Drawing I Trouble Shooting I Cleaning Limited Warranty USA Only Specifications 3 4 5 6 7 8 9 10 11 12 13 18 19 20 21 ...

Page 4: ...ns contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts americandj com ADJ SERVICE USA Monday Friday 8 00am to...

Page 5: ...er warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly writ ten on the outside of the return package A brief description of the problem as well as the R A num ber must also be written down on a piece of paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You...

Page 6: ...d Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product outdoors voids all warranties Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be...

Page 7: ...ion against particles entering the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS NOT suitable for marine and or coastal envir...

Page 8: ...event water ingress condensation and or corrosion The Encore Burst 100 IP is fully operational in three different mounting positions hanging upside down mounted sideways on trussing or set on a flat level surface Be sure this fixture is kept at least 12m 40ft away from any flammable materials decoration etc Screw one clamp via a M12 screw and nut into the Omega bracket Insert the quick lock fasten...

Page 9: ...ts LLC www adj com Encore Burst 100 IP User Manual Page 8 Encore Burst 100 IP Overview CONTROL PANEL LCD SCREEN MODE UP DOWN ENTER BUTTONS SAFETY CABLE RIGGING POINT 5 PIN DMX OUT 5 PIN DMX IN POWER IN POWER OUT ...

Page 10: ...in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Encore Burst 100 IP can be controlled via DMX 512 protocol The Encore Burst 100 IP has 4 DMX channel modes Your unit and your DMX controller requires a 5 pin XLR co...

Page 11: ...ddresses for each individual fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of DMX channels of each fixture Th...

Page 12: ...ULSE STROBING LED ON RANDOM STROBING SLOW FAST LED ON 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255 VALUES FUNCTIONS 1 1 2 1 CH 2 CH 3 CH 4 CH 2 1 1 2 DIMMER FINE 0 100 000 255 DIMMER CURVES SPEED STANDARD STAGE TV ARCHITECTURAL THEATRE STAGE 2 DIMMER SPEED FAST SLOW 0 1S 10S DEFAULT TO UNIT SETTING 000 020 021 040 041 060 061 080 081 100 101 120 121 140 141 255 3 3 4 ...

Page 13: ...Effect Adjust Calibration WW LED 000 255 Factory Restore Password 11 Tungsten Effect Backlight Control Factory Settings Power On Time XXXXXX Hours P On Time R XXXXXX Hours P On Time Reset Password 50 Current XXX Max Resettable XXX Max Not Resettable XXX Rst Temp History Password 50 Calibration LED Refresh Setting Manual Control Total Running Time Not Resettable Total Running Time Resettable Reset ...

Page 14: ...unit to automatically revert to if the DMX signal is lost or interrupted Hold Last If the DMX signal is lost or interrupted the unit will stay in the last DMX setting Blackout If the DMX signal is lost or interrupted the unit will automatically go into standby mode Manual If the DMX signal is lost or interrupted the unit will default to the settings made under the Manual Control function See Manua...

Page 15: ...n Backlight and Display Lock Press the ENTER to select the setting you would like to adjust 3 Use the UP or DOWN buttons to toggle between ON and OFF for each function Backlight ON will keep the display on at all times and OFF will have the display turn off after 20 seconds To light the display press 1 of the 4 buttons Display Lock ON will lock the display control after 30 seconds and OFF will lea...

Page 16: ...ON running time of the fixture will now be displayed Press the MENU button to exit P On Time R With this function you are able to check current power ON running time of the unit This running time may not be the same as the total power ON running time displayed under POWER ON TIME This time CAN be reset NOTE The displayed time represents the current power ON running time since the last reset 1 Pres...

Page 17: ... ENTER 2 Press the UP or DOWN buttons until Fixture Life Time is displayed and press ENTER 3 Press the UP or DOWN buttons until LED On Time R is displayed and press ENTER 4 The power ON running time of the fixture will now be displayed Press the MENU button to exit LED Time Reset With this function you can reset the current LED ON time that is displayed under LED ON TIME R 1 Press either the MENU ...

Page 18: ...isplayed and press ENTER 4 The fixtues hightest temperature will now be displayed Press the UP or DOWN buttons to switch between farenheit and celsius Press the MENU button to exit Rst Temp History With this function you can reset the MAX RESETTABLE temperature NOTE When the temperature is reset the temperature will revert to the CURRENT temperature 1 Press either the MENU UP or DOWN buttons until...

Page 19: ...ER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE CHECK SILK SCREEN FOR MAX AMPS Encore Burst 100 IP Dimmer Curve Chart DIMMER 100 50 10 0 Time ms 0 Sec 255 255 0 0 Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time ms Down Time ms Rise Time ms Do...

Page 20: ...tors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be car ried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts co...

Page 21: ...will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear indentifyin...

Page 22: ...D Color Temperature 2700k 1200k Tungsten Mode IP Rating 65 Working Position Any safe working position Power Draw 115W Weight 9 25 lbs 4 2 Kgs Dimensions 9 21 L x 9 8 W x 12 12 H 234 x 249 x 308mm DMX Channels 4 DMX Modes 1 2 3 4 Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice ...

Reviews: