background image

Page   1
R e v. : 0 0 2

Micro-Scope II

Lighting Technologies

Instruction
Manual

ME 2033

1106.02.033

Micro-Scope II

Lighting Technologies

Summary of Contents for Micro-Scope II

Page 1: ...Page 1 Rev 002 Micro Scope II Lighting Technologies Instruction Manual ME 2033 1106 02 033 Micro Scope II Lighting Technologies ...

Page 2: ...Page 2 Rev 002 Micro Scope II Lighting Technologies ...

Page 3: ...Page 3 Rev 002 Micro Scope II Lighting Technologies Instruction Manual ...

Page 4: ...ror Indicator 8 Loop Through Indicator 8 Max Min Mode 9 Detail Mode 9 Trigger Output 9 Generating DMX512 10 Transmit Rig Check 10 Transmit Preset 10 Transmit Dynamic DMX512 11 Presets 11 Snapshot DMX to Preset 11 Fill Preset with Pattern 11 Testing Cables 12 Double Ended Cable Test 12 Single Ended Cable Test 12 Auto Backup 13 Loop Through 13 Start Codes 13 Displaying Received MIDI 14 MIDI Trigger ...

Page 5: ...nologies Product Registration Form Product Micro Scope II Version No Serial No Date Purchased Supplier Name Company Name Address Post Zip Code Phone No Comments Please return to ADB TTV Technologies LEUVENSESSTEENWEG 585 B 1930 ZAVENTEM BELGIUM ...

Page 6: ...rted Please remember to return your product registration card so that we can keep you informed of new developments Features Micro Scope provides the following features Receives DMX512 MIDI Display as barchart decimal percentage or hexadecimal Display update rate channels received Break and MaB time Display maximu minimum and current value of a single channel Double and single ended cable test Gene...

Page 7: ...e is in DISPLAY RECEIVED DMX512 the TOGGLE key is used to step through the different display formats bar graph percent decimal etc In TRANSMIT mode the TOGGLE key is used to invert the lever of the selected channel LEFT RIGHT When Micro Scope is in DISPLAY RECEIVED DMX512 the LEFT and RIGHT cursor keys are used to select a new base address In TRANSMIT DMX512 modes the LEFT and RIGHT cursor keys ar...

Page 8: ...T 15 5 Presets Used to create show backup or record useful test patterns FILL PRESET Fill one of the 15 Presets with a WITH PATTERN 6 symmetrical pattern of channel levels DOUBLE ENDED Fully test all three pins of DMX512 or CABLE TEST 7 MIDI cables for shorts and open circuits SINGLE ENDED Test the two signal pins of DMX512 or CABLE TEST 8 MIDI cables for shorts when only the console cable end is ...

Page 9: ... are Bar Graph Decimal Percent Hex Max Min Detail Status The first four display formats also include the following information 1 DMX512 base address 2 Display mode 3 Data received indicator 4 Data error indicator 5 Loop Through indicator The diagram below shows Micro Scope receiving DMX512 in bar graph mode 1 DMX512 Base 2 Display Mode 3 Data Received 5 LoopThrough 4 Data Error DMX Base Adresse Th...

Page 10: ... use bit control See Appendix for conversion tables Data Received Indicator This character cell displays a tilde to show that data is being received The data is not necessarily valid DMX512 Data Error Indicator This character cell is clear when good data is being received If an error occurs one of the following is displayed H DMX512 is being received with a non matching Header or stars code F Data...

Page 11: ...specification requires this value to be 88uS or greater If this is not the case the timing error icon T will be displayed in the main receive window The third number C represents the number of dimmer channels received in the last DMX packet This number should be constant although the value may be less than 512 depending on the type of console used The fourth number is the Mark after Break time MaB...

Page 12: ...o be transmitted to the dimmers and also edited Each Preset contains individual level settings for all 512 channels and is held in non volatile memory The Preset to be transmitted and edited is selected by the UP and DOWN keys when the menu display is active Press the MENU key to enter edit mode CHANNEL 001 100 11111111 SFF 255 The following keys are active LEFT Decrement the dimmer channel RIGHT ...

Page 13: ...set to a lower value than the start channel all output channels are set to zero The DMX512 output continues when Micro Scope is in Receive mode Presets Snapshot DMX to Preset The SNAPSHOT menu allows any one of the fifteen Presets to be filled with data captured from the DMX512 input The Preset to be used is selected by the UP and DOWN keys when the menu display is active Press the MENU key to tak...

Page 14: ...able Micro Scope can test for short circuits and open circuits on any of the three active pins of the DMX512 cable The SINGLE ENDED TEST is used when only the console cable end is accessible Micro Scope can test for a short circuit between the two signal pins Double Ended Cable Test The DOUBLE ENDED TEST display shows the connectivity of each of the three active pins of the DMX512 or MIDI cable An...

Page 15: ...eset AUTO BACKUP mode When AUTO BACKUP is active the UP and DOWN keys are used to snap between consecutive Presets AUTO BACKUP 15 ACTIVE DMX FAIL Loop Through The BUFFER DMX MIDI option is used to selected between Micro Scope s Generator output and a buffered copy of the incoming DMX512 signal The loop through mode is selected by pressing the TOGGLE key when the menu is displayed The BUFFER mode o...

Page 16: ...Thetriggeroutputprovidesanactivelowpulse312uS aftertheMIDIcharacter Start Bit Power Supply and Charger Micro Scope has an internal Ni Cd rechargeable battery which provides a life of about 30 hours between recharges The external 9 Volt 300mA DC power supply is used to power and recharge Micro Scope As with all Ni Cd battery products the best battery life is obtained by completely discharging Micro...

Page 17: ... should this conflict with your DMX512 implementation A MIDI adapter cable can be simply constructed from the following wiring plan FEMALE 5 PIN XLR FEMALE 5 PIN DIN Pin 1 Connect to screen No connection Pin 4 Pin 4 Pin 5 Pin 5 TRANSMIT FEMALE 5 PIN XLR Pin 1 Screen Pin 2 DMX Transmit Signal Pin 3 DMX Transmit Signal Pin 4 Trigger output Pin 5 Trigger ground The Trigger feature of Micro Scope uses...

Page 18: ... 4C 0100 1100 13 0D 0000 1101 45 2D 0010 1101 77 4D 0100 1101 14 0E 0000 1110 46 2E 0010 1110 78 4E 0100 1110 15 0F 0000 1111 47 2F 0010 1111 79 4F 0100 1111 16 10 0001 0000 48 30 0011 0000 80 50 0101 0000 17 11 0001 0001 49 31 0011 0001 81 51 0101 0001 18 12 0001 0010 50 32 0011 0010 82 52 0101 0010 19 13 0001 0011 51 33 0011 0011 83 53 0101 0011 20 14 0001 0100 52 34 0011 0100 84 54 0101 0100 21...

Page 19: ...D 0110 1101 141 8D 1000 1101 173 AD 1010 1101 110 6E 0110 1110 142 8E 1000 1110 174 AE 1010 1110 111 6F 0110 1111 143 8F 1000 1111 175 AF 1010 1111 112 70 0111 0000 144 90 1001 0000 176 BO 1011 0000 113 71 0111 0001 145 91 1001 0001 177 B1 1011 0001 114 72 0111 0010 146 92 1001 0010 178 B2 1011 0010 115 73 0111 0011 147 93 1001 0011 179 B3 1011 0011 116 74 0111 0100 148 94 1001 0100 180 B4 1011 01...

Page 20: ...0 1011 204 6C 0110 1100 236 EC 1110 1100 205 6D 0110 1101 237 ED 1110 1101 206 6E 0110 1110 238 EE 1110 1110 207 6F 0110 1111 239 EF 1110 1111 208 70 0111 0000 240 FO 1111 0000 209 71 0111 0001 241 F1 1111 0001 210 72 0111 0010 242 F2 1111 0010 211 73 0111 0011 243 F3 1111 0011 212 74 0111 0100 244 F4 1111 0100 213 75 0111 0101 245 F5 1111 0101 214 76 0111 0110 246 F6 1111 0110 215 77 0111 0111 24...

Page 21: ...Page 21 Rev 002 Micro Scope II Lighting Technologies ...

Page 22: ...Page 22 Rev 002 Micro Scope II Lighting Technologies Notes ...

Page 23: ...Page 23 Rev 002 Micro Scope II Lighting Technologies Notes ...

Page 24: ...eselstraße 4 D 63165 Mühlheim am Main Tel 49 6108 91 250 Fax 49 6108 91 25 25 E Mail adblighting t online de France ADB S A S Sales office 168 170 boulevard Camélinat F 92240 Malakoff Tel 33 1 41 17 48 50 Fax 33 1 42 53 54 76 E Mail adb fr adblighting com Factory group logistics centre Zone industrielle Rouvroy F 02100 Saint Quentin Tel 33 3 23 06 35 70 Fax 33 3 23 67 66 56 E Mail adb fr adblighti...

Reviews: