background image

Designer Flueless Fires

INSTALLATION & USERS INSTRUCTIONS

X-FIRE 600

Product Codes 

HIW-XF20 - Limestone model

HIW-XF21 - Granite model

X-FIRE 750

Product Codes

HIW-XF22 - Limestone model

HIW-XF23 - Granite model

Leave with the User

Revision B - 03/12

Acquisitions of London

24-26 Holmes Road

London NW5 3AB

Tel: 0044 (0)207 482 2949

Email: [email protected]

X-FIRES

600-750 

Country(s) of destination : GB, IE

Product Identification No. 86/CM/061

Summary of Contents for X-FIRES 600

Page 1: ...Granite model X FIRE 750 Product Codes HIW XF22 Limestone model HIW XF23 Granite model Leave with the User Revision B 03 12 Acquisitions of London 24 26 Holmes Road London NW5 3AB Tel 0044 0 207 482 2949 Email sales acquisitions co uk X FIRES 600 750 Country s of destination GB IE Product Identification No 86 CM 061 ...

Page 2: ... this booklet is owned by Acquisitions of London You are not permitted to copy or adapt any of the content without the prior written permission of Acquisitions of London The products covered by this booklet are protected under patents GB2275331B GB2429186B and GB2413178B 750 600 2012 Acquisitions of London ...

Page 3: ...e discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On no account should the appliance inlet or outlet openings be blocked or obstructed in any way see figure 1 On first ...

Page 4: ...ice is continuously mains powered and arranged in such a way that the gas sup ply to the appliance is isolated in the event of an alarm The selection and installation of such device shall be in accordance with the current edition of BSEN 50292 and the user must be briefed regarding the use and maintenance of such a device Installation in living rooms is common however other rooms such as kitchens ...

Page 5: ...l of the appliance The wall must be structurally sound and constructed from a material capable of withstanding moderate heat Brick concrete finished plaster most types of conventional wall paper and dry lined plasterboard are examples of suitable materials Materials such as flock blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or ...

Page 6: ...any cables sockets outlets which may already be buried Pipes must be secured using suitable clips and pro tected against corrosion Ideally factory finished pro tected pipework and fittings should be used Joints should be kept to a minimum and compression fit tings must not be used The pipework installation must be tested for soundness before any protection is applied and or the pipework and fittin...

Page 7: ...e is hung on the wall Drill the wall as appropriate for the type of wall as previously described in this section and insert the chosen type of wall fixings Insert the wall fixing screws into the top wall plugs taking care to leave the screws pro truding approximately 5mm from the wall Now hang the appliance onto these screws through the two keyhole shaped holes in the upper brackets on the back pa...

Page 8: ...ease SPARK FAILURE The gap between the spark electrode and the pilot should be 3 5 4 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric spark fails the pilot cannot be lit manually SETTING PRESSURE The pressure test point is located on the inlet restrictor elbow in the centre of the burner as shown in figure 8 Release the pressure test ...

Page 9: ...f section 8 4 3 Remove the glass door assembly 4 screws and clean carefully 4 Inspect the burner and the catalyst and clean if necessary with a soft brush 5 Disconnect the gas supply 6 Detach the burner front cover plate by removal of the four retaining screws Undo the four screws retaining the burner support brackets to the base and rear of the firebox Remove the control knob and spindle assembly...

Page 10: ... should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the cat alyst New seals will usually be required The performance of the catalysts may be checked using a combustion gas analyser as follows Any analyser used should conform to EN 50379 3 A suitable analyser is a Telegan Sprint 2000 XT Combustion Flue Gas Analyse...

Page 11: ... HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THER...

Page 12: ...of the control knob and control panel Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See rel evant section for further details on clearances to combustibles No combustible materials or flooring should protrude onto the hearth if fitted This appliance incorpora...

Page 13: ...tc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installation The back of the appliance may be installed directly onto a combustible wall providing it is relatively flat and does not interfere with the various vent holes in the back panel of the appliance The wall must be structurally sound and c...

Page 14: ... OFF call in your installer to check the appliance and ventilation Remedial work must be carried out as required DO NOT allow the appliance to be used until the appliance and installation is passed as safe If the pilot continues to be extin guished you must call your installer to check the operation of the complete appliance CLEANING Before carrying out any of the following operations ensure that ...