Read instRuctions below caRefully befoRe attempting to install, opeRate oR seRvice shutteR motoR.  

Retain instRuctions foR futuRe RefeRence.

We recommend shutter not be mounted closer to the fan than 1/3 the diameter of fan blade. Do not force 

shutter into opening! Do not open shutter by lifting individual blades! Do not install shutter leaning forward or 

backward!

general safety information

1.  Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the 

Occupational Safety and Health Act (OSHA) in the United States.

2.  Motor must be securely and adequately grounded. This can be accomplished by wiring with a grounded, 

metal-clad raceway system, by using a separate ground wire connected to the bare metal of the motor 

frame, or other suitable means.

3.  Always disconnect power source before working on or near a motor or its connected load. If the power 

disconnect point is out-of-sight, lock it in the open position and tag to prevent unexpected application of 

power.

4.  Protect the power cable from coming in contact with sharp objects.
5.  Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or 

chemicals.

6.  Make certain that the power source conforms to the requirements of your equipment.

figure 2

 - Wiring Diagrams

OUTSIDE 

OF WAll

INSIDE

OF WAll

SHUTTEr

MOUNTINg SCrEWS

(NOT INClUDED)

DO NOT TIgHTEN 

MOUNTINg SCrEWS 

TOO TIgHT

FAN  

ASSEMbly

(by OTHErS)

AIr

FlOW

figure 1

Wiring Diagram - 120V, 60 Hz

l1

l2

grd.

grd.

Insulated

grd.120v

Power 

Supply 

lines

Switch

black

White

red

green

Shutter

Motor

Fan

Motor

Wiring Diagram - 240V, 60 Hz

l1

l2

grd.

grd.

Insulated

grd.240v

Power 

Supply 

lines

Switch

red

White

black

green

Shutter

Motor

Fan

Motor

Installation of Fiberglass Motorized Wall Shutters

1.  Shutter frame should be mounted level and 

squarely on outside wall. Care should be taken not 

to twist the shutter frame. Never cover  

shutter with siding or masonry work. Shutter should 

be mounted so it can be removed any time in 

case of damage.

2.  Use tie rod only to test opening and closing of 

shutter.

3.  Shutter should operate as freely after installation 

as it did before.

4.  Caulking compound is recommended between 

shutter frame edges and the wall.

5.  Clean and lubricate shutter at the same time that 

the fan is lubricated and cleaned.