INSTRUCTION MANUAL 

IS-D105 

Intrinsically Safe Sounder

 

 
The IS-D105 is an ATEX and IECEx certified intrinsically safe 
sounder which produces a loud warning signal in a 
hazardous area. Forty-nine first stage alarm sounds can be 
selected by internal switches and each one can be externally 
changed to a second or third stage alarm sound. The 
sounder may be used in all gas groups IIA, IIB and IIC. An IS-
DL105 intrinsically safe combined sounder and beacon is 
also available.

 

 

2)  Ratings and Markings

 

 

2.1 ATEX/IECEx certification 
 

The IS-D105 sounder complies with the following standards:-  
 
EN60079-0:2012 / IEC60079-0:2011 
EN60079-11:2012 / IEC60079-11:2011 
IEC 60079-26:2014 
 
 

 

 
The EC-Type Examination Certificate SIRA 04ATEX2301X 
has been issued by the Notified Body Sira. This confirms 
compliance with the European ATEX Directive 94/9/EC for 
Group II, Category 1 G equipment.  The sounder carries the 
Community Mark and subject to local codes of practice, may 
be installed in any of the EEA member countries. The product 
has also been approved to the IECEx scheme, Certificate no. 
IECEx SIR04.0038X. This instruction sheet describes 
installations which conform to EN60079-14:2008/IEC60079-
14:2007 Electrical Installation in Hazardous Areas. When 
designing systems for installation outside the UK, the local 
Code of Practice should be consulted. 
 
 

 
The certification marking is as follows: 
 
1) 

The certificate number has an ‘X’ suffix, which 
indicates that the certificate contains one or more 
special conditions for safe use. Those installing or 
inspecting the equipment should refer to this section 
of the certificate. 

2) 

The equipment has not been assessed as a safety-
related device (as referred to by Directive 94/9/EC 
Annex II, clause 1.5). 

3) 

Installation of this equipment shall be carried out by 
suitably-trained personnel in accordance with the 
applicable code of practice. 

4) 

Repair of this equipment shall only be carried out by 
the manufacturer or in accordance with the 
applicable code of practice. 

5) 

The certification of this equipment relies on the 
following materials used in its construction: 

 

 

Enclosure: Aluminium Pressure Die Cast Body LM6 

 

Sealing of Enclosure & Mechanism: ‘O’ Ring

 

 

 

 

If the equipment is likely to come into contact with 
aggressive substances, then it is the responsibility of 
the user to take suitable precautions that prevent it 
from being adversely affected, thus ensuring that the 
type of protection is not compromised. 

 

“Aggressive substances” - e.g. acidic liquids or 
gases that may attack metals, or solvents that may 
affect polymeric materials. 

 

“Suitable precautions” - e.g. regular checks as part 
of routine inspections or establishing from the 
material’s data sheet that it is resistant to specific 
chemicals. 

 
2.2  Zones, Gas Groups and Temperature Classification 
 

The IS-D105 sounder has been certified Ex ia IIC T4 Ga. 
When connected to an approved system it may be installed 
in: 
 
 

Zone 0 

explosive gas air mixture 

 continuously 

present. 

 

Zone 1 

explosive gas air mixture likely to occur in 
normal operation. 

 

Zone 2 

explosive gas air mixture not likely to occur, 
and if it does, it will only exist for a short time. 

 

Be used with gases in groups: 

 

 

 Group 

IIA 

propane 

 Group 

IIB 

ethylene 

 Group 

IIC 

hydrogen 

 

Having a temperature classification of: 

 

T1 450ºC 
T2 300ºC 
T3 200ºC 
T4 135ºC 

The IS-D105 sounder is CE marked for 

compliance with the European 

Explosive Atmospheres Directive 

94/9/EC and the European EMC 

Directive 89/336/EEC 

II 1G     Ex ia IIC T4 Ga (-40ºC <= Ta <= +60ºC) 

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for IS-D105

Page 1: ...ated device as referred to by Directive 94 9 EC Annex II clause 1 5 3 Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice 4 Repair of this equipment shall only be carried out by the manufacturer or in accordance with the applicable code of practice 5 The certification of this equipment relies on the following material...

Page 2: ...pply voltage is available 3 2 Terminals S2 and S3 When terminals S2 or S3 are connected to 0V terminal the sounder output tone changes to the second or third stage alarm respectively The input safety parameters for these terminals are Ui 28V Ii 0mA Because the permitted input current is zero these terminals may only be connected to a diode return barrier an intrinsically safe relay or a galvanic i...

Page 3: ...Single stage alarm If the control switch is in the positive supply or the power supply is being turned on and off only a single channel Zener barrier is required as shown in Fig 3 This circuit may also be used if the sounder is being controlled by a mechanically activated switch on the hazardous area side of the barrier Fig 4 Single stage alarm using single channel barrier If the control switch mu...

Page 4: ...S D105 sounder second and third stages may be activated by using Galvanically Isolated Relays that have output parameters within the limits specified in section 4 4 which have been certified Ex ia by an EC Notified Body Fig 8 Multi stage alarm using galvanic isolated relays 7 Cable Parameters The maximum permitted cable parameters are as specified on the certificate of the Zener barrier or galvani...

Page 5: ...en Slow rise to 2400Hz Intermittent 1000Hz 1s ON 1s OFF Sawtooth 1200 500Hz 1Hz D I N PFEER P T A P Intermittent 1000Hz 1s ON 1s OFF PFEER General Alarm 420Hz 0 625s Australian Alert 500 1200Hz 3 75s 0 25s Australian Evacuate 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 ...

Reviews: