manualshive.com logo in svg
background image

Содержание Thunderbreaker

Страница 1: ......

Страница 2: ...Stallation and Splicing 6 4 Description 8 4 1 Control Ption 8 5 How To Set The Unit 9 5 1 Main Function 9 6 Control By Universal DMX Controller 18 6 1 DMX512 Connection 18 6 2 Address Setting 19 6 3 DMX512 Configuration 20 7 Troubleshooting 50 8 Fixture Cleaning 50 1C ...

Страница 3: ...overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 40 DO NOT connect the device to any dimmer pack Make sure there are no flammable materials close to the unit while oper...

Страница 4: ...iginal packing materials before transporting it again DO NOT look directly at the light while the Luminaires is on DO NOT start on the unit without Luminaires enclosure or when housing is damaged Installation The fixture should be mounted via its Omega Quick Release Clamp bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating and make sure that the stru...

Страница 5: ...onstruction Display Color display Data In Out 3 pin 5 pin XLR is optional Power In Out Power Connector in out Protection Rating IPX4 Number of connected machines Maximum number of connected DMX machines 32 Maximum number of power supply units 120V 60Hz 4 units 230V 50Hz 8 units Features 144 zones can be controlled individually Black shell no traces of screws Excellent powerful and high output stro...

Страница 6: ...5C Dimension Weight 503 x 183 x 318mm 10 5kgs 19 8 x 7 2 x 12 5 in 23 1lbs ...

Страница 7: ...e when installing the equipment use a safety rope that can support 12 times the weight of the product The equipment must be installed by professionals The equipment should be installed in a place where the human body cannot be touched and there will be no pedestrians passing by or sitting The installation height of the lamp is between 0 30M Installation method of single adjustable angle lamp hange...

Страница 8: ... Installation method of lamp hanger optional The splicing method of multiple lamps Warning Up to 7 units can be spliced in the vertical direction 7C ...

Страница 9: ...er into move backward or leave the menu UP To go backward to move up in the menu DOWN To go forward to move down in the menu ENTER To perform the desired functions 5 DMX IN DMX512 link use 3 pin XLR cable to link the unit and DMX controller 5 pin XLR is optional 6 DMX OUT DMX 512 operation use 3 pin XLR cable to link the next units 5 pin XLR is optional 7 Ethernet interface connect to the network ...

Страница 10: ...on until the required function is shown on the monitor Select the function by the ENTER button Use the UP DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press the MENU button or let the unit idle One minuteto exit menu mode The main functions are shown below 9C ...

Страница 11: ...nformation Fixture Use Hour LED Use Hour Temperature Firmware Version Error Logs Total LED Hour LEDHours Reset LED On Hour Fixture Errors Reset Error Log No Yes Passsword 050 No Yes Special Functions Factory Restore Passsword 050 6 Channel 11 Channel 12 Channel 13A Channel 13B Channel 17 Channel 21A Channel 21B Channel 29 Channel 37 Channel 41 Channel 53 Channel The internet IPAdaresl Submask XXXX...

Страница 12: ...the display use the UP DOWN button to select 6 Channel 11 Channel 12 Channel 13A Channel 13B Channel 17 Channel 21A Channel 22B Channel 29 Channel 37 Channel 41 Channel or 53 Channel press the ENTER button to save Press the MENU button to return to the previous menu or wait one minute to automatically exit the menu mode DMX Last State Select the DMX Last State press the ENTER button to confirm The...

Страница 13: ...X XXX press the MENU button to exit Press the MENU button to return to the previous menu or wait one minute to automatically exit the network mode Pixel settings Select the pixel setting press ENTER button to confirm use UP DOWN button to select Ethernet setting press ENTER button to confirm use UP DOWN button to select Net Universe Add 1 xxx xxx xxx xxx Or 2 xxx xxx xxx xxx after selecting the de...

Страница 14: ...re finer and at high values the lines are thicker inverse square rate when the light intensity is controlled at a low value the lines are thicker and when the light intensity is controlled at a high value the lines are thinner S Curve The line is finer when the light intensity is controlled at low and high values and the line is thicker at the middle value Dimming Speed Select the Dimming speed an...

Страница 15: ...l be displayed on the display use the UP DOWN button to select OFF or ON press the ENTER button to save Press the MENU button to return to the previous menu or wait one minute to automatically exit the menu mode Temperature Unit Select the Temperature Unit press the ENTER button to confirm the current mode will be displayed on the display use the UP DOWN button to select or press the ENTER button ...

Страница 16: ...machine will run according to channel value Press the menu button to return to the previous menu or wait for one minute to exit the menu mode automatically after exiting the manual test menu all channel values will become zero Device Information Enter the MENU mode select Device Information press the ENTER button to confirm use the UP DOWN button to select Use time LED Use Hours Temperature Firmwa...

Страница 17: ...button to exit Firmware version Select the Firmware version press the ENTER button to confirm the firmware version of the device will be displayed on the screen press the MENU button to exit RDM UID Select Select the RDM UID Select press the ENTER button to confirm XXXXXX on the display press the MENU button to exit Error Message Select the Error Message press the ENTER button to confirm use the U...

Страница 18: ...on number of the fixture will be displayed Select the DMX START ADDRESS menu to change the DMX 512 address 001 512 Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture Select the DEVICE LABEL menu to change the model of the fixture Select the DMX PERSONALITY menu to set the channel mode of the fixture 6 11 12 13A 13B 17 21A 21B 29 37 41 53 channel Select the DMX PERSONALITY...

Страница 19: ... to exit Green1 Green20 Enter offset mode Select one of the Green1 Green20 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 1000 press the ENTER button to store Press the MENU button to exit Blue1 Blue20 Enter offset mode Select one of the Blue1 Green20 press the ENTER button to confirm the present position will b...

Страница 20: ...ot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the c...

Страница 21: ...n use the UP DOWN button to select the address code 1 512 press the ENTER button to save Press the MENU button to return to the previous menu or wait one minute to automatically exit the menu mode Please refer to the chart below to set the address codes of the first 4 lamps Channels 灯具 1 地址码 灯具 2 地址码 灯具 3 地址码 灯具 4 地址码 6 Channels 1 7 13 19 11 Channels 1 12 21 31 12 Channels 1 13 25 37 13A Channels ...

Страница 22: ...o below configurations to control the fixtures Attentions 1 The unit will maintain the last condition until reset if you cut off the DMX signal 2 For the channel Function keep the value for about Five seconds then the corresponding function will take into effect 21C ...

Страница 23: ...ness 11 Red Green Blue White Art Net or DMX 0 127 machine controlled by Art Net 128 255 machine controlled by DMX Channel Function DMX Channel Function DMX Blue White Fine tuning Blue Fine tuning White Brightness Fine tuning Art Net or DMX 0 127 machine controlled by Art Net 128 255 machine controlled by DMX 22C ...

Страница 24: ...23C ...

Страница 25: ...24C ...

Страница 26: ...8 9 25C 7 ...

Страница 27: ...26C ...

Страница 28: ...27C ...

Страница 29: ...28C ...

Страница 30: ...29C ...

Страница 31: ...30C ...

Страница 32: ...31C ...

Страница 33: ...32C ...

Страница 34: ...33C ...

Страница 35: ...13A channel 17 channel 21A channel 29 channel 37 channel 41 channel 53 channel 13B Channel 21B channel 34C ...

Страница 36: ...35C ...

Страница 37: ...36C ...

Страница 38: ...37C ...

Страница 39: ...38C ...

Страница 40: ...39C ...

Страница 41: ...40C ...

Страница 42: ...41C ...

Страница 43: ...42C ...

Страница 44: ...43C ...

Страница 45: ...44C ...

Страница 46: ...45C ...

Страница 47: ...14D 46C ...

Страница 48: ...15D 47C ...

Страница 49: ...48C ...

Страница 50: ...eck if the fan is damaged Check if there are other interference items in the fan operating range Check if the fan circuit on the motherboard breaks down Check if the component is damaged Check if the fan is out of order 1 LED Fan Error 6 4 Error Message Fan Distribution Diagram of the machine 49C ...

Страница 51: ...ther DMX controller 5 Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal and exte...

Страница 52: ...Innovation Quality Performance ...

Отзывы: