background image

 

   

 

 

 

                     

 

 

 

 

LP-TS200 CW 

LP-TS200 WW 

 

 

 

                         

          

User Manual 

     

Please read the instruction carefully before use 

 

Summary of Contents for LP-TS200 CW

Page 1: ...LP TS200 CW LP TS200 WW User Manual Please read the instruction carefully before use ...

Page 2: ...e for Color Filter Barn Door Installation 6 5 How To Set The Unit 7 5 1 Control panel 7 5 2 Main Functions 8 6 How to Control the Unit 12 6 1 Master Slave Function 12 6 2 DMX Controller 12 6 3 DMX 512 Configurations 13 7 DMX 512 Connections 13 8 Troubleshooting 14 9 Fixture Cleaning 15 1C ...

Page 3: ...ation at least 50cm from adjacent surfaces Be sure to locate the unit in a place away from adjacent surfaces at least 1M Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid elec...

Page 4: ...must be replaced if they are visibly damaged DO NOT open the unit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Please disconnect the mains power if the fixture is not used for a long time DO use original packing materi...

Page 5: ...CW 3200 200K LP TS200 WW Rotating filter and hanger Thermo optical cooling technology with quiet Suitable for theaters studios retail stores and other similar locations Power supply AC 100 240V 50 60Hz Power consumption 226W Physical temperature 56 C Working life 50 000 hours CRI Ra 90 Weight 19 3Kgs Dimension 438 368 7 624 1mm 400 438 368 7 344 6 512 2 624 1 111 9 4C ...

Page 6: ...Photometric Diagram 3 Accessories Standard Accessories Simple Bracket Optional Accessories Adjustable Bracket 5C ...

Page 7: ...late for Color Filter into the inside slot from topside Fig 2 Secondly please insert the Barn Door into the outside slot from topside as arrow A 3E A and fasten the lock Note the Barn Door must be fastened into the inside of the lock s hook then flip down the lock cap again as arrow A 4E A Finally as arrow A 5E A please fasten the safety cable in the iron coils of Barn Door 6C ...

Page 8: ... 3 Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions 4 Zoom Manual adjust the zoom value 5 Dimmer Manual adjust the dimmer value 6 Power Switch Used to turn On Off the fixture 7 Fuse T 5A Used to protect the unit from damage of the over current 7C ...

Page 9: ... 2 Main Functions To select any functions press the MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to th...

Page 10: ...present address will blink on the display Use the UP and DOWN button to adjust the DMX address from 1 to 512 Once the address has been selected press the ENTER button to save Hold and press the MENU button about one second or wait for one minute to exit the menu mode 9C ...

Page 11: ... to save Hold and press the MENU button about one second or wait for one minute to exit the menu mode Display Settings Enter menu mode select Display Settings press ENTER button to confirm use UP DOWN button to select Backlight Intensity Backlight Auto Off Display Inverse or Language Backlight Intensity Select Backlight Intensity press the ENTER button to confirm present mode will blink on the dis...

Page 12: ...ual Test press the ENTER button to confirm Use the DOWN and UP button to select the Zoom Position or Dimmer Value mode Once selected use the DOWN and UP button to adjust the value 0 255 and press the ENTER button to save Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Information Enter menu mode select Fixture Information press the ENTER button...

Page 13: ...rogram functions 2 Universal DMX controller 6 1 Master Slave Function By linking the units in master slave connection without DMX control the first unit will control the other units to give a synchronized light show 6 2 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channels so that the units can receive DMX signal Press the MENU button a...

Page 14: ... Unit 2 Address Unit 3 Address Unit 4 Address 2 Channels 1 3 5 7 6 3 DMX 512 Configurations 2 Channels Mode 7 DMX 512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels output 13C ...

Page 15: ...hting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 8 Troubleshooting Following are a few common proble...

Page 16: ... The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 9 Fixture Cleaning The cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the uni...

Page 17: ... the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 1BHarmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance 16C ...

Reviews: