PLMK10100 

Nexello bypass opening detector

 

 

 

 

 
 
 

 

 

Important information and FAQs about this product and other 

products can be found on the website 

www.abus.com

 

 

 

 

Manual version: 1.2 

firmware version: 1.41 

 

 

Summary of Contents for Nexello PLMK10100

Page 1: ...PLMK10100 Nexello bypass opening detector Important information and FAQs about this product and other products can be found on the website www abus com Manual version 1 2 firmware version 1 41 ...

Page 2: ...44 Affing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 h Fri 08 14 h All contained company names and product names are trademarks of their respective owners All rights reserved Disclaimer This operating manual has been prepared with the utmost care Should you nevertheless notice any omissions or inaccuracies please notify us in writing at the addres...

Page 3: ...ust For exact specifications check the technical data of the individual units Ensure that there is always sufficient ventilation that no direct heat sources act on the unit that no direct sunlight or strong artificial light falls on indoor units that the unit is not in the immediate vicinity of magnetic fields e g speakers that no open fire sources e g In particular the device must never be submer...

Page 4: ... cleaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy water Use only suitable microfibre cloths for high gloss surfaces Make sure that no water gets inside the device Do not clean the appliance in the dishwasher Do not use sharp pointed abrasive corrosive cleanin...

Page 5: ...rview 8 2 1 Inclusion Teach in device 8 2 2 Planning assembly and installation 10 2 3 Exclusion Device teach in 12 2 4 Reset to factory settings 13 2 5 Wake up Wake up device 13 2 6 Behavior Bypass button 14 3 Advanced Z Wave Parameters 15 3 1 Association Groups 15 3 2 WakeUp Time 15 3 3 Reports 16 3 4 Overview configuration parameters 17 3 5 Supported command classes 18 3 6 Supported security lev...

Page 6: ...on reset error D Markings For correct alignment of sensor and magnet E Battery compartment Observe polarity F Sabotage contact Triggers sabotage alarm G Mounting For mounting on the window H Link Button Manual triggering of the wake up command inclusion exclusion and reset I Front cover magnet Contains the magnet Must be correctly aligned with the sensor J Holder Magnet For mounting on the window ...

Page 7: ...ng detector is suitable for mounting on door window frames due to its design is Z Wave Plus compatible certified supports the Z Wave S2 standard Security 2 has a low battery warning function was developed for indoor installation 1 5 Use in systems of different manufacturers This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All mains pow...

Page 8: ...troller does not support SmartStart follow these instructions for Product Classic Inclusion Activate the inclusion mode teach in mode on the gateway for more details refer to the operating instructions of the gateway Or in your Z Wave app press the button Add Inclusion and follow the instructions to set the gateway to inclusion mode Keep the device within range of the gateway Remove the safety str...

Page 9: ... displayed in the app or on the gateway and the status LED on the device lights green for 2 seconds Repeat the inclusion process if it was not successful If a new attempt fails as well first carry out a factory reset on the device see 2 5 ...

Page 10: ...tal surfaces are urgently advised against for technical reasons Fasten the sensor holder to the window or door Place the base on the holder Fasten the holder of the magnet to the frame with the enclosed adhesive pad or screws Place the base on the holder and if necessary change the height adjustment of the magnet by pulling out the grid If necessary use the supplied spacers to compensate for diffe...

Page 11: ...glish Make sure that the product fronts of sensor and magnet are as flush as possible use the grids for adjusting the height of the magnet for minor adjustments and the spacers supplied for major adjustments ...

Page 12: ...move Exclusion in your Z Wave app and follow the instructions to set the gateway to Exclusion mode Using the pin press the Link button 3 times quickly within 1 5 seconds to start the exclusion on the device The LED starts flashing red for up to 60 seconds The successful exclusion is displayed in the app or on the gateway and the status LED on the device lights up red for 2 seconds ...

Page 13: ...ings Hint This procedure should only be used if the primary gateway is not capable of acting If the device is set to factory default the status is set to not included and the association settings and possible configurations are reset to default 2 5 Wake up Wake up device Press the Link button once to wake up the device It will then establish a connection to the Z Wave gateway and transmit the curr...

Page 14: ...is reported again If the door or window is still open after 5 minutes the opening detector emits an opening alarm The bypass function can be deactivated via the parameter setting Scene control The Bypass button can distinguish between four different button presses 1 Press 1x briefly 2 Press 2x briefly 3 Long pressure Longer than one second 4 Release the key only applies if the key is pressed Long ...

Page 15: ... Group 1 5 Lifeline General notification report battery report Device Reset Locally Notification Central Scene Notification Group 2 5 on off control Notification basic set Group 1 Association Z Wave Controller The Lifeline Association is automatically established between the Z Wave controller and the device during inclusion and defines what information is exchanged between the Z Wave controller an...

Page 16: ... 0x03 Battery alarm replace soon 0x08 0x0A 0x00 Battery alarm replace now 0x08 0x0B 0x00 Battery alarm acknowledgement 0x08 0x00 0x01 0x0A 0x0B Battery report Value Description 0x05 0x64 5 100 Battery charge level in percent 0xFF 256 Low battery Central Scene Report Sent when the bypass button is pressed Event Attribute Key number Press 1x briefly 0x00 0x01 Release press and hold for a long time 0...

Page 17: ...50 in percent Hexadecimal 0x05 0x32 14 1 BASIC SET to association group 2 motion alarm 0 BASIC SET should be sent after a motion alarm 0 Disabled 1 Active Hexadecimal 0x00 0x01 15 1 Invert value of BASIC SET command 0 Set the value of the BASIC SET command for movement alarm and acknowledgement 0 The motion alarm sends the BASIC SET value On 0xFF the acknowledgement sends the BASIC SET value Off 0...

Page 18: ...ware Update Md Version 5 Indicator Version 3 Manufacturer specific Version 2 Multi Channel Association Version 3 Notification Version 8 Power level Version 1 Security Version 1 Security 2 Version 1 Supervision Version 1 Transport Service Version 2 Version Version 3 Wake up Version 2 Z wave Plus Info Version 2 3 6 Supported security levels Security S2 Authenticated Security S2 Unauthenticated Secur...

Page 19: ...nsmitting power 5 dbm Power supply 3 V DC Type of battery 1x CR2 Battery life 2 years Sabotage protection Yes Firmware updateable Yes OTA Z Wave manufacturer ID 0x0403 Z Wave Product Type ID 0x0002 Z Wave Device ID 0x0006 Z Wave Beaming supported No Z Wave SmartStart supported Yes Z Wave Plus supported Yes Z Wave Network Security Yes Z Wave AES 128 Security S0 Yes Z Wave S2 Security Yes S2 Authent...