background image

PAGE 1

ABTRONIC™X86S Fitness Belt

USER MANUAL

Summary of Contents for X8S

Page 1: ...PAGE 1 ABTRONIC X86S Fitness Belt USER MANUAL ...

Page 2: ...hoice of the ABTRONIC X8S Fitness Belt Please read this manual before first use CONTROLS A self timer switches the unit off after 10 minutes PROGRAM Button to change 6 programs ON Button increase Intensity OFF Button decrease Intensity LED Light 2 LED Light 1 ...

Page 3: ...s used to select one of the 6 preprogrammed exercise modes The setting is indicated by the color and location of the two LED lights on the unit The AbTronic X8S unit has the following 6 exercise modes Program LED 1 LED 2 Description 1 RED Off Fast Blaster very fast 5 pulses per second 2 Off RED Fast exercise 1 pulse per second also tapping massage 3 RED RED General exercise 3 sec on 2 sec rest tim...

Page 4: ...itness Belt OPERATION BATTERY 1 Open the battery door by pushing it in the direction of the arrow 2 Insert one piece CR 2032 Lithium battery into the battery compartment The positive pole of the battery should be facing you ...

Page 5: ... the X silicon pad holder Insert the controller by aligning the marking on the controller case with the holder Insert the control unit aligning it with the shorter marking on the holder at position 1 and turn it clockwise until it aligns with the longer marking on the holder at position 2 ...

Page 6: ...utions APPLYING GEL SHEETS 1 Take the gels sheets out of the bag and peel off one side of the protective film which has no wording from the gel sheet 2 Stick the gel sheets onto each of the 2 conductive areas on the rear side of the X stimulation pad Please make sure the gel sheet has protective film which has no wording is stick onto the simulation pad If there is an air bubbles under the gel she...

Page 7: ...s wording and ready to stick on your skin Do not peel off the gel sheet affixed to the electrode until you need to replace them with new ones 4 Gel Sheet Storage After use do NOT remove the gel sheets but put it onto the Storage Board this prevents the gel sheets getting dirty while not in use Pad Storage Board ...

Page 8: ...of New Gel Sheets Please visit www abtronic co for purchasing NEW gel sheet ABTRONIC X8S PLACEMENT ABTRONIC X8S was design to be used to effectively target individual muscle groups on your abs legs and arms and other positions Please see below diagram with recommended exercise points However the ABTRONIC X8S is a personalized training tool and can be adapted to suit the individual If the below con...

Page 9: ...ONIC X8S control unit 2 Select the Mode by pressing the Mode button repeatedly Every time you press the Mode button a different LED or combination will light up indicating one of the 6 preprogrammed routines BACK FRONT A A A A B B C G D H E K N M N M I I I F F J J J J F F L P P L O Q O Q I ...

Page 10: ...e turn the unit off before repositioning Hint DO NOT USE gel or creams that contain oils with the product 3 Push the ON button several times to carefully increase the intensity Adjust the intensity according to your comfort level You should feel a light tingling Push ON button 10 x to increase intensity 10 steps Push OFF button 10 x to decrease intensity 10 steps 0 1 2 3 4 5 6 7 8 9 10 ...

Page 11: ... operation However please use the system for 4 to 6 consecutive cycles day for best results Auto Functions When the conductive area of the belt silver colored area does not touch the skin the intensity can only be set up to 1 If the belt is removed during use the intensity is automatically reset to 1 If the belt is not placed back into contact with the skin the unit will turn off after 20 seconds ...

Page 12: ...occur This can also happen if the body has built up excessive oils on the skin Before each use please ensure that the contact points are thoroughly clean and the gel sheet is not worn or dirty A discoloration of the conductive area is normal Do not wash or immerse the product in water or use fabric cleanser If there is redness or irritation on applied area after removal of the ABTRONIC X8S from yo...

Page 13: ...t covered by the guarantee It should be noted however that this is the most advanced generation design and that lasts much longer than comparable products The ABTRONIC X8S is extremely energy efficient The Batteries last for approx 100 sessions of ten minutes If the output becomes weak or the unit switches off automatically in less than 10 minutes it is time to change the batteries even if the LED...

Page 14: ...rantee FREQUENTLY ASKED QUESTIONS Q How does the ABTRONIC X8S really work A ABTRONIC X8S is designed to copy the messages sent from your brain to the abdominal muscle during exercise This message causes the muscle to contract and relax Q Can muscles become over developed or strained A No the principle is the same for general training of muscles the more exercise with suitable periods of rest the s...

Page 15: ... all contra indications on the last page carefully Q When should I notice any effect A Depending on the frequency of use and body fat you should notice increases in abdominal strength within 2 4 weeks Abdominal muscle tone will show within approximately 4 weeks after incorporating the ABTRONIC X8S into your program Q I am getting a prickling sensation but no contraction A Move the ABTRONIC X8S sli...

Page 16: ...ses ABTRONIC X8S should NOT be used on injured or otherwise impaired muscles ABTRONIC X8S should NOT be used on the heart area WARNINGS 1 The long term of chronic electrical stimulation are unknown 2 Apply electrodes ONLY to normal intact clean skin 3 DO NOT APPLY STIMULATION Over the carotid sinus nerves Over the neck or mouth Severe spasms of the laryngeal and pharyngeal muscles may occur with c...

Page 17: ...cture Following recent surgery If you have a hernia abdominal or lingual To the frontal laryngeal and temporal regions of the neck 4 Never use the ABTRONIC X8s while driving operating machinery or during activities in which involuntary muscle contractions may endanger the user or others 5 Do not use the ABTRONIC X8s in the bath or shower 6 Persons with suspected heart problems or epilepsy should o...

Page 18: ...ablished 2 Place electrodes in accordance with illustrations in the User Manual 3 Users should start all sessions in a sitting or prone position minimum for the first 5 minutes 4 This unit should not be used while driving operating machineryorduringanyactivityinwhichinvoluntarymuscle contractions may place the user at undue risk of injury ADVERSE EFFECTS Skin irritation and burns beneath the elect...

Page 19: ...Check polarity sign Replace batteries LEDs light up but nothing happens No skin contact Control unit not connected to the pad correctly Microprocessor hang up Battery is low Use gel sheet on conductive pads and place it directly onto skin Check that control unit is connected firmly with AtronicX pad Increase intensity by pushing the up button Perform a RESET remove Batteries for 1 minute for full ...

Page 20: ...e use new gel sheets Move the AbTronic around to locate your trigger points switch off when moving Replace gel sheets Replace Battery LEDs light up but all buttons do not work Microprocessor hang up Battery is low Perform a RESET remove batteries for 1 minute for full RESET Change Battery IMPORTANT POWER RESET If the unit does not switch on or if you can t change to different programs the micropro...

Page 21: ... Power Supply 3V CR2032 battery Frequency Adjustable due to different modes Pulse Width Adjustable due to different modes Contraction Time Adjustable due to different modes Relaxation Time Adjustable due to different modes Ramp Time Adjustable due to different modes Timer Default time is 10 minutes Max Charge per pulse Adjustable due to different modes Battery Life Approximately 16 hours at nomina...

Page 22: ...This product is brought to you by AbTronic by Red Lemon Incorporation www abtronic co www red lemon com by Red Lemon Incorporation MMXV RLX8sEngV1 2 ...

Reviews: