Summary of Contents for BANC CLASSIC

Page 1: ...lease read carefully and keep available for later use 01 2022 Version AE 12 205 6EN 01 2022 ABOVE WATER SLATTED SAFETY COVER OPEN SURF System OPEN SURF System S l a t t ed cover s sta n da r d Compliant with the NF P 90 308 ...

Page 2: ...OOL s experience in manufacturing automatic slatted covers since 1995 It will allow users to make the best use of this product which should give compete satisfaction Compliant with the highest requirements our safety cover was designed to prevent children younger than 5 years old from accessing the pool when it is unrolled and locked CAUTION The floating slatted safety cover is not a substitute fo...

Page 3: ...EN SURF 2 solar 12 3 10 Final overall dimensions of the OPEN SURF2 slatted cover 13 3 11 Final overall dimensions of the RAISED OPEN SURF 13 4 Electric connections 4 1 Cabled model 14 4 2 Stand alone and stand alone solar models 15 4 3 Solar cabled model 16 5 Assembling the slats 6 Limit switch adjustments 6 1 End of unrolling 17 6 2 Fixing the slat cover to the roller shaft 17 6 3 Adjustment of t...

Page 4: ...g and in watertight and accessible boxes located outside of volume 0 of the swimming pool as per the NF C 15 100 standard 1 1 5 Cable exit Determine the cable output position once the rails have been installed and the stand position is known 1 1 6 Earthing In compliance with the NF C15 100 standard it is imperative that all pools be fitted with earthing in compliance with standard requirements to ...

Page 5: ... 1 on the pool liner at the level of the edge opposite the cable exit 1 3 3 Measure a precise length A of 1 m less than the length of the pool and make a mark 2 at the end of A on the pool liner 1 3 4 On the opposite length make a mark 3 opposite mark 1 Important items 1 and 3 while complying with squaring must be located as close as possible to being plumb with the rear coping edges for right ang...

Page 6: ...r weighs 295 kg and measures 4 6 x 0 6 x 0 8 h 2 1 3 For a 5 x 10 pool the container weighs 395 Kg and measures 5 6 x 0 6 x 0 8 h Fig 5 0 8 m x 0 6 m W 4 2 4 7 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 X 4 6 5 1 5 6 6 6 7 6 8 6 9 6 10 6 11 6 12 6 2 2 Reception 2 2 1 Open the container in the presence of the delivery staff and check the condition of the goods and their compliance Keep the original packing...

Page 7: ...cut to embed the rail on the bearing block side 25 x 45 mm 45 80 25 Spacing between rails pool 700 mm approx Minimum width cut to embed the rail on the motor side 25 x 80 mm Fig 8 3 3 Assembling the rails SURF 1 and 2 3 3 1 1st rail Fig 9 Place the OPEN SURF System symmetrically on the pool and check that the roller tube is perpendicular to the pool lengths see fig 3 In the case of a SURF System 2...

Page 8: ... rail so that it is parallel to the pool Fig 13 Fig 14 Pre drill all the other holes keeping the OPEN SURF close to the hole to be drilled in order to maintain a constant gap between the rails Fig 14 Fig 15 Remove the OPEN SURF from the rail and pivot the rail to one side in order to enlarge the holes to Ø 8 mm Fig 15 Fig 16 Insert all the other anchors into the holes and fix the rail using the sp...

Page 9: ...els bring the power supply cable to the stand Fig 18 Fig 19 Power supply stand Mark the 4 holes using the plate 6 and drill using a Ø 12 mm bit Fit the threaded rods 5 using chemical sealer The rods must protrude 342 mm above the ground Fit the square tube 4 and connect the 24 volt input cable using the supplied screw terminal Place the plate with the notch 3 and screw the 4 bolts 2 Place the top ...

Page 10: ... from the edge of the rail The length of the bar must be adjusted from the end of the rail and finish 9 cm from the sides of the coping Carry out tests to check that the cover opens over the pool electric connections 4 If this is not the case readjust the bar Fig 22 9 cm 3 mm OPEN SURF System 1 OPEN SURF System 2 9 cm 10 mm Fig 23 Next mark all the holes and drill using a Ø 6 mm bit and fit the M5...

Page 11: ...ing Surf 1 covers Using an Allen wrench unscrew the TRHC M6 x 16 screw lift then remove the cover from the stand Fig 27 Fig 28 3 7 2 Removing Surf 2 covers Using an Allen wrench unscrew the 4 lateral TRHC M6 x 16 screws to release the cover Tilt it carefully backward then lower it Be careful there are two pins below the aluminium frame to position the cover on it The cover must be removed from the...

Page 12: ... 12 13 14 15 X 290 300 310 320 330 340 350 360 370 380 390 400 X 3 9 Removing the solar panel OPEN SURF 2 solar Dismantle the motor cover see 3 6 to access the connectors Fig 30 Disconnect the red and black wires connected to the and solar terminals of the regulator Attach a needle grommet to each of the two wires Fig 30 Fig 31 Remove the rivets then dismantle the solar panel from the beam Take ca...

Page 13: ... shaft dimensions Pool width 596 mm Beam width Pool width 636 mm Overall dimensions Pool width 910 mm 140 3 10 Final overall dimensions of the OPEN SURF2 slatted cover Pool length 8 m 10 m 12 m D min diameter needed 560 mm 620 mm 660 mm 100 100 25 15 345 35 35 65 65 38 225 Centre distance of rails Pool width 700 mm Roller shaft dimensions Pool width 588 mm Beam width Pool width 628 mm Overall dime...

Page 14: ...he connecting cable to the terminals marked and in the box Fig 32 230V AC 24V DC ON OFF T N P 2A 4 1 2 Connect the power cables to the screw terminal inside the stand Fig 33 Test the tube s rotation in both directions The slats should roll by passing over the roller shaft If the movement does not match to the correct direction invert the blue and brown wires Let the tube turn in the unrolling dire...

Page 15: ...g 32 Connect the 230 V power supply cable in the electric box to the terminal marked T for the earth P for the phase and N for the neutral Connect the two power wires of the connecting cable to the terminals marked and in the box 4 2 2 Remove the cover see 3 6 and connect the violet wire to the batteries Connect the power wires to the screw terminal in the stand and connect the violet wire to the ...

Page 16: ...F cabled solar model electric diagram SURF System 1 Connect the spiral wire to the screw terminal inside the previously installed solar stand SURF System 2 The solar panel is assembled on the SURF frame and its wires are already connected to the regulator Remove the cover see 3 6 and connect the violet wire to the batteries Fig 31 Test the tube s rotation in both directions The slats should roll b...

Page 17: ...ends on wires 1 and 2 of the motor cable and not directly the box and Check the condition and the correct tightening of the electric connections 7 1 For the models with a box 7 1 1 Checking the box Check that the fuse and the thermal circuit breaker are in working order Disconnect the 2 wires connecting the box to the roller motor from the and terminals Turn the switch on the electric box to On or...

Page 18: ...egulator must be returned to AS POOL for analysis Rectifier test 24 V DC Direct Current on the square rectifier the terminal is perpendicular to the other 3 terminals The terminal is diagonally opposite Thermal circuit breaker test 24 V DC on the terminals marked and at the connecting cable connections If a voltage is not present or of a different value check again making sure that the multimeter ...

Page 19: ...f the cover making sure that the motor cable does not get entangled Lock the safety mechanisms When commissioning the roller a new adjustment of the motor limit switches will be needed 7 3 4 Checking the sensor Use the continuity measurement on your multimeter to check that the contact opens and closes when it is pushed If nothing happens the sensor is defective It must be replaced 8 Checks Check ...

Page 20: ...safety mode see troubleshooting 10 1 2 The regulator emits light signals to warn the user of a change in the state of the batteries 10 2 Troubleshooting 1 2 3 Charge level Yellow LED 1 comes on at 75 Yellow LED 2 comes on at 25 Yellow LED 3 comes on at 10 Yellow LED 3 flashes at 10 Flashing red LED flashing short circuit Red LED on safety Green LED on charging Battery connection Use connection Sol...

Page 21: ... be SOUTH facing West North South East Oriented towards full sunlight producing 100 of its power 11 3 Projected shade and surrounding vegetation PLEASE REMEMBER The SOLAR PANEL must not be in any SHADE from an object or the surrounding vegetation In full sunlight but with the shadow of the key holder example above the panel produces 87 of its power The key must be removed from after each use The s...

Page 22: ...r an Open Close cycle Full batteries can power 40 cycles while leaving enough in reserve to allow a safety closure In comparison a 6 m x 12 cover that consumes an average of 3 A in 6 minutes uses 7 2 Wh or 4 of the batteries 11 4 Solar kit element winterisation PLEASEREMEMBER TheSOLARPANELandthecharge REGULATOR can STAY IN POSITION over the WINTER If the SOLAR PANEL is NOT COVERED and continues to...

Page 23: ...Safety instructions and user guide for the automatic pool cover Please read carefully and keep available for later use 01 2022 Version AE 12 018 12EN 01 2022 Slatted covers ...

Page 24: ...children Drowning happens very quickly Children close to a pool require constant monitoring and active supervision even if they can swim The physical presence of a responsible adult is indispensable when the pool is open Learn the actions that save lives Memorise the emergency service phone numbers and display them near the pool Fire Brigade 112 Ambulance 15 Poison Centre Write down the No This co...

Page 25: ...The sound level generated by the automatic safety cover when running is 65 dB 0 0UV FERM The cover is controlled using a control that is locked using a key or an access code placed in the immediate pool vicinity Casing can cover the roller for a more aesthetic look or to isolate the bathing area Safety systems are located at the ends of the slatted cover to fix it to the pool when it is fully unro...

Page 26: ...s complete 6 Keep a permanent view over the cover and the pool while it is moving Make sure to keep people away from the roller 7 Keep the control key or the remote control out of the reach of children 8 UNROLLING THE COVER Before covering the pool make sure there are no bathers in the pool 9 Use the control key or enter the remote control code 10 Insert the key into the barrel and activate the Cl...

Page 27: ...ause brownish stains to appear on the slats This natural phenomenon is not covered by our guarantee 3 Advice for use Always check that the pool water level remains constant and in compliance with the manufacturer s recommendations 12 cm as a standard before using the cover in order to avoid jamming the slats in the trench against the beam or the partition wall or to prevent them from rubbing again...

Page 28: ...ter level regulation overflow not clogged automatic filling correctly set Make sure that the area where the cover motor is located is fitted with a drain preventing the motor from being submerged at all times in case of flooding Check that the slats are not subjected to temperature differences greater than 15 between the outside air and the water in order to prevent them from warping case of a hig...

Page 29: ... on the specificities of the pool AS POOL does not communicate directly with pool owners Have the automatic cover serviced by a swimming pool professional we recommend your swimming pool installer whose details are on the cover of this manual who will be able to contact our technical assistance department All spare parts must be original spare parts in order to maintain our guarantee and the cover...

Page 30: ...ht the batteries must be disconnected and stored in a dry place When putting back into service let the batteries charge a half day of sunlight before operating the cover 7 Guarantee Our one year guarantee only covers the replacement or the repair of a defective part as well as all defects or faults in the context of the installation use maintenance and winterisation in compliance with our instruct...

Page 31: ... Blue PVC Light grey PVC Galet grey PVC Blue tinted two ply PVC Clear polycarbonate Blue tinted translucent polycarbonate Blue tinted two ply polycarbonate Mother of pearl tinted two ply polycarbonate Clear black two ply polycarbonate Black fumée polycarbonate Signature and stamp mandatory write the words read and approved MANDATORY INFORMATION FOR VALIDATION OF THE GUARANTEE Checks carried out on...

Page 32: ...ric box check the 10A 30mA ground fault circuit breaker The on off button on the box is ON Fuses are in good condition 12 V or 24 VDC voltage on the motor power terminals when the key is turned Continuity of contacts of the key switch when the key is turned 12 V or 24 VDC polarised voltage on the 2 motor power wires in the connection box when the key is turned The wire connections in the connectio...