background image

2TMD041800D0026

  23.04.2019

Product manual

ABB-Welcome

M2238.-. Video indoor station 7
M2238.-.-02 Video indoor station 7

Summary of Contents for M2238 Series

Page 1: ...2TMD041800D0026 23 04 2019 Product manual ABB Welcome M2238 Video indoor station 7 M2238 02 Video indoor station 7 ...

Page 2: ...unted installation 12 7 6 Flush mounted installation 14 7 7 Cavity wall installation 15 7 8 Desktop installation 16 7 9 Dismantling 16 8 Commissioning 17 8 1 Initial setup 17 8 2 Enter system setting 19 8 3 Camera list 20 8 4 Sound 22 8 5 Display 23 8 6 Date and time 24 8 7 Automatic snapshot 25 8 8 Door status check 26 8 9 Missed call notification 27 8 10 Unlock password 28 8 11 Program button se...

Page 3: ...ntercom 55 9 3 1 Enter intercom page 55 9 3 2 Add contacts 55 9 3 3 Initiating an intercom call 56 9 3 4 Add to blacklist 57 9 3 5 Restoring a contact from the blacklist 58 9 4 Surveillance 59 9 4 1 Surveillance without the camera list 59 9 4 2 Surveillance with the camera list 60 9 5 Call guard unit 61 9 6 Pager 62 9 7 History 63 9 8 Voice message 66 9 9 Absence message 67 9 10 Call forward 69 9 ...

Page 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Page 5: ...D card Type Micro SDHC Capacity 4 32 G Speed Class10 File system FAT32 Please use a SD card complying with SDHC standard some SD cards may not perform correctly It is recommended to use SanDisk Kingston Transcend SDHC cards which are fully tested and verified Do not remove SD card or reboot indoor station while recording or copying images onto the SD card otherwise this SD card may fail to preform...

Page 6: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 7: ...ase the 2nd lock connected with outdoor station Programmable for additional function e g switch on the light unlock by relay 5 Mute button In standby mode press this button to mute the ringtone on this indoor station In standby mode press and hold this button for 3 s to mute the ringtone of all indoor stations in the same apartment When a call is coming in press this button to reject the call Duri...

Page 8: ...ts tens digits selector switch X1 sets units digits Dip switches X100 and X200 set hundreds digits 5 Master slave function switch Only one indoor station in each apartment can be set as Master ON Master 6 Terminal resistor switch In video installations or mixed audio and video installations the switch must be set as RC on on the last device of the line ON RC on 7 Microphone 8 Dismantling switch 9 ...

Page 9: ... voltage range 20 30 V DC Standby current 24 V DC 12 mA Operating current 24 V DC 330 mA Operating temperature 10 C 55 C Display size 7 Resolution 1024 x 600 pixel Single wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Fine wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Product dimensions 198 5 mm 162 3 mm 17 mm ...

Page 10: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 11: ...o avoid interference Do not install the wires of the system bus together with 100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a four core or multi core cable When looping never install the incoming and outgoing bus inside the same cable Never instal...

Page 12: ...Mounting Installation Product manual 2TMD041800D0026 12 7 5 Surface mounted installation Surface mounted box 120 7 mm 120 7 mm 83 3 mm 89 mm 170 8 mm 144 3 mm 7 9 2 m m 60 mm 83 3 mm ...

Page 13: ...Mounting Installation Product manual 2TMD041800D0026 13 Surface mounted installation 1 4 5 3 2 ...

Page 14: ...Mounting Installation Product manual 2TMD041800D0026 14 7 6 Flush mounted installation 6 7 8 9 10 11 4 5 1 2 3 3 54 mm 144 mm 192 mm ...

Page 15: ...Mounting Installation Product manual 2TMD041800D0026 15 7 7 Cavity wall installation 1 2 3 4 5 7 6 8 9 ...

Page 16: ...Mounting Installation Product manual 2TMD041800D0026 16 7 8 Desktop installation 7 9 Dismantling 1 2 3 4 5 1 2 ...

Page 17: ...8 Commissioning 8 1 Initial setup When this device is powered up for the first time or when the Clear all data function on Engineering settings screen is used the indoor station enters initial setup 1 Choose country or region 2 Select system language ...

Page 18: ...Commissioning Product manual 2TMD041800D0026 18 3 Read license agreement 4 Set date and time ...

Page 19: ...Commissioning Product manual 2TMD041800D0026 19 8 2 Enter system setting In standby mode on the extra screen click SYSTEM to access the System Settings screen ...

Page 20: ...0026 20 8 3 Camera list On the System Settings Camera list screen click Camera list to access the corresponding screen Click to synchronize all cameras on outdoor stations and cameras connected to the camera interfaces to create a camera list ...

Page 21: ...and then click Save to save an icon to the camera list On the Camera list screen click to access the settings No Function 1 Set an alias for outdoor stations or cameras 2 Set visual doorbell function for cameras 3 Hide the device in the camera list 4 Delete the device from the camera list 5 Clear all devices from the camera list ...

Page 22: ...nce 4 Ringtone settings Click the drop down list to select the ringtones for the default outdoor station other outdoor stations the doorbell and other devices 5 built in ringtones 5 Customized ringtone 3 customized ringtones wav only can be added from an SD card The toal size of 3 customized ringtones is 10 M A customized ringtone will appear on the drop down list of ringtone settings after being ...

Page 23: ... screen No Function 1 Clean screen Click to lock the screen for 30 s Please see the Clean screen chapter for more details 2 Brightness Drag the bar to adjust the brightness 3 Auto full screen Enable disable the full screen mode on the outdoor station camera by ticking unticking the checkbox ...

Page 24: ...creen No Function 1 Time setting Click or to set hour and minute Choose time format 12 hours or 24 hours from the drop down list 2 Date setting Click or to set the year month and day Choose the date format from the drop down list 3 Surmmer time Enable disable summer time by ticking unticking the checkbox ...

Page 25: ... 8 7 Automatic snapshot On the System settings Door Entry System screen click switch button to enable disable the function When this function is enabled three snapshots are taken and automatically saved to the history record when the bell is pressed ...

Page 26: ...reen click the radiobutton to enable disable the function When this function is enabled the outdoor station will send an alarm to this indoor station when the door is open over 120 s A sensor should be connected to the outdoor station first The indoor station will flash all its button LEDs until the door is close ...

Page 27: ...MD041800D0026 27 8 9 Missed call notification On the System settings Door Entry System screen click the radiobutton to enable disable the function If this function is enabled the call button LED will flash to indicate the missed call ...

Page 28: ...26 28 8 10 Unlock password On the System settings Door Entry System screen click the radiobutton to enable disable the function When this function is enabled you can set a password to release the lock connected to the outdoor station 3 8 digits ...

Page 29: ...D041800D0026 29 8 11 Program button setting On the System settings Door Entry System screen program button is set to Release 2nd lock by default It will be disabled if it is set to None Press the button to enable the defined function ...

Page 30: ...ct here followed by a lock from the drop down list Please see the Standby unlock chapter for more details If the standby switch has been selected in the light settings Switch on light can be selected here followed by a light from the drop down list Please see the Standby switch on the light chapter for more details ...

Page 31: ...Commissioning Product manual 2TMD041800D0026 31 8 12 Language On the System Settings Language screen select the language ...

Page 32: ...Enter engineering setting On the System Settings Engineering setting screen enter the engineering password to enter the settings screen the system default engineering password is 345678 this password is only used to set a new engineering password and must be changed after first use ...

Page 33: ...41800D0026 33 8 13 2 Device settings The Engineering setting Device settings screen includes the settings described below Surveillance mode If this function is disabled it is not possible to start the surveillance by pressing the button ...

Page 34: ...Commissioning Product manual 2TMD041800D0026 34 Manual snapshot If this function is disabled it is not possible to take a manual snapshot during a call ...

Page 35: ...Commissioning Product manual 2TMD041800D0026 35 Auto unlock If this function is disabled the will be hidden on the status bar ...

Page 36: ...ommissioning Product manual 2TMD041800D0026 36 Copy snapshot to SD card If this function is disabled it is not possible to copy snapshots to SD card on the History screen even when an SD card is inserted ...

Page 37: ...Commissioning Product manual 2TMD041800D0026 37 Delete history data If this function is disabled it is not possible to delete the record on the History screen ...

Page 38: ...Commissioning Product manual 2TMD041800D0026 38 Edit camera list If this function is disabled it is not possible to rename the camera ...

Page 39: ...Commissioning Product manual 2TMD041800D0026 39 Open dedicated outdoor station If this function is enabled it is possible to release the lock on dedicated outdoor station 1 9 ...

Page 40: ...40 Auto snapshot It is possible to set auto snapshot start after 1 s or 3 s Selecting 1 s means this device will take a snapshot automatically at 1 s 3 s and 5 s Selecting 3 s means this device will take a snapshot automatically at 3 s 5 s and 7 s ...

Page 41: ...uct manual 2TMD041800D0026 41 8 13 3 Customized extra page On the Engineering setting Customized page screen tick the check box to enable the functions The icons for these functions will be displayed on the extra screen ...

Page 42: ...ick Engineering password to change the password in the pop up window Note Engineering password must be changed at the first time you enter engineering setting The system default is 345678 This password should only be used for initial setting work and should then be changed to another password It cannot be used as the actual password ...

Page 43: ...5 Clear all data On the Engineering setting Clear all data screen click clear all data OK This function is only available within 120 s after the indoor station is powered on and will restore all user settings and engineering settings to the default value ...

Page 44: ...uto snapshots Enable Door status check Enable Missed call notification Enable Program button setting Release the 2nd lock Door open password Null Repeated tone on Touch tone on Leaving message off Call forward off Auto unlock off Mute off Click Change user password enter the original password and a new password to set the new user password Reset user password Reset engineering password and Reset d...

Page 45: ...D041800D0026 45 8 13 7 Device address On the System settings About screen it is possible to view the address of this device 8 13 8 Version information On the System settings About screen it is possible to view the version information ...

Page 46: ...oning Product manual 2TMD041800D0026 46 8 13 9 Obtain product manual On the System settings About screen there is a QR code that can be scanned to access the website Click Downloads Manual to download the file ...

Page 47: ...Commissioning Product manual 2TMD041800D0026 47 8 13 10 Disclaimer On the System settings About screen it is possible to view the disclaimers e g OSS and EULA ...

Page 48: ...D0026 48 8 13 11 Firmware update It is possible to obtain the latest version on the website via scanning the QR code Click Downloads Software to download the files Note These 2 update files must be saved in the root directory on the SD card ...

Page 49: ...g Product manual 2TMD041800D0026 49 Note This function is only available when an SD card is inserted On the System settings About screen click Firmware update click the file and then click OK to update the firmware ...

Page 50: ...extra screen The content of extra screen can be customized on System settings Engineering settings 2 SOS In standby mode hold for 3 s to send SOS to the guard unit 3 Intercom In standby mode click to enter intercom screen Please see the Intercom chapter 4 Call guard unit In standby mode click to call guard unit Please see the Call guard unit chapter 5 Pager In standby mode click to initial an inte...

Page 51: ...In standby mode click to view the history records Please see the History chapter 7 Voice message In standby mode click to view the voice messages Please see the Voice message chapter 8 Status bar Display the date time and the status information for this indoor station ...

Page 52: ...tion gate station 3 Click anywhere on the screen to switch to full screen 4 Snapshot manually Click to capture and save pictures to the internal memory when ringing or during a conversation 5 Press to talk Press and hold for 3 s to switch the speech direction from this device to the other side 6 Record audio and video Press to record audio and video to the SD card when ringing or during a conversa...

Page 53: ...Operation Product manual 2TMD041800D0026 53 9 2 2 Call from guard unit indoor station No Function 1 Caller ID 2 Volume Click or to adjust the volume ...

Page 54: ...the doorbell is pressed the device will display for 5 s on the status bar If the doorbell is associated with the camera in the camera list settings the device will display the corresponding camera automatically for 15 s Please see the Visual doorbell chapter for more details ...

Page 55: ...041800D0026 55 9 3 Intercom 9 3 1 Enter intercom page In standby mode click on the home screen to access the corresponding screen 9 3 2 Add contacts On the Intercom screen click to access the settings Click to create a new contact ...

Page 56: ...ation Product manual 2TMD041800D0026 56 9 3 3 Initiating an intercom call On the Intercom Favorite contacts screen click to initial an intercom No Function 1 Caller ID 2 Volume Click or to adjust the volume ...

Page 57: ...access the corresponding screen Select Blocked from the drop list to add the contact to blacklist It is possible to add a contact to the blacklist directly on the History screen On the History screen click to add the caller ID to blacklist directly Only the caller ID on the favorite list can be added to the blacklist ...

Page 58: ...oduct manual 2TMD041800D0026 58 9 3 5 Restoring a contact from the blacklist On the Intercom Blocked screen click to access the settings Select Allowed from the drop list to add the contact to favorite contact list ...

Page 59: ...e station 3 Click to see next image 4 Click to see full screen image 5 Snapshot manually Click to take a snapshot and save the picture to internal memory during ringing and conversation 6 Press to talk Press and hold for 3 s to force the speech direction from this device to other side 7 Record audio and video Press to record audio and video to an SD card during ringing and conversation when an SD ...

Page 60: ... press the button to access the Camera list screen if there is a camera list Click the designated outdoor station or camera to view the image Press the button again to quit the surveillance Press the button during the surveillance to initial a communication and press the button again to end the call ...

Page 61: ...Operation Product manual 2TMD041800D0026 61 9 5 Call guard unit In standby mode click on the home screen to call guard unit No Function 1 Caller ID 2 Volume Click or to adjust the volume ...

Page 62: ...duct manual 2TMD041800D0026 62 9 6 Pager In standby mode click on the home screen This indoor station will initial an internal call to all indoor stations in the same apartment This broadcast will last maximum 30 s ...

Page 63: ...peration Product manual 2TMD041800D0026 63 9 7 History In standby mode click to view the history A maximum of 100 DES communication records can be stored Highlighting indicates that the record is unread ...

Page 64: ...al 2TMD041800D0026 64 Click to play the audio or video record in the pop up window an SD card must be inserted Click the image to view details in the pop up window Click or to change the images max 3 pictures for each record ...

Page 65: ...er the settings It is possible to delete history records one by one or to delete all the records at once with one click Snapshots can be copied to the SD card if an SD card is inserted If the disk space of SD card is full will be displayed on the status bar ...

Page 66: ...andby mode click to access the corresponding screen Click to access the settings Click to add a new voice message Click the Rec button to start recording a voice message and click the Play button to play the voice message A maximum of 10 voice messages can be recorded ...

Page 67: ...r visitors and to record voice message from visitors Enable Absence message At least one voice message must exist before this function can be used On the Voice message screen tick the check box to enable the function Note The functions Call forward and Auto unlock will be disable if this function is activated ...

Page 68: ...eration Product manual 2TMD041800D0026 68 Disable Absence message On the extra screen click Leave home management to access the screen Click the radiobutton to OFF to disable the absence message function ...

Page 69: ...r guard unit automatically On the extra screen click Leave home management to access the screen When the function is enable it is possible to select the indoor station or guard unit to forward the incoming call Forward time can be set to 1 30 s Note The functions Absence message and Auto unlock will be disable if this function is activated ...

Page 70: ...Operation Product manual 2TMD041800D0026 70 9 11 Automatic unlock On the Engineering settings Device settings screen tick the checkbox to enable the function Click on the status bar to access the screen ...

Page 71: ...m allows you to select the days of the week with the selected options shown in highlighting After setting the start time and end time click OK to save This device supports a maximum of 10 auto unlock settings Note The functions Absence message and Call forward will be disable if this function is activated ...

Page 72: ...ration Product manual 2TMD041800D0026 72 9 12 Standby unlock On the Engineering setting Customized page screen tick the checkbox to enable the function On the extra screen click Unlock to access the screen ...

Page 73: ...ng Type Description Address Connected object Default lock Lock is connected to outdoor station Address 1 9 Lock is connected to switch actuator Unlock mode 1 OFF 2 ON Address 1 9 associated with outdoor station 2nd lock Lock is connected to outdoor station Address 1 9 Actuator Lock is connected to switch actuator Relay mode 1 ON 2 OFF Address 1 199 ...

Page 74: ...al 2TMD041800D0026 74 On the Unlock screen click on a designated lock to release that lock The screen will display and the status bar will display This device supports a maximum of 16 standby locks Default lock Actuator lock ...

Page 75: ...oduct manual 2TMD041800D0026 75 9 13 Standby switch on light On the Engineering setting Customized page screen tick the checkbox to enable the function On the extra screen click Switch on light to access the screen ...

Page 76: ...complete the setting Type Description Address Connected object Actuator Lock is connected to switch actuator Relay mode 1 ON 2 OFF Address 1 199 On the Switch on light screen click on a designated light icon to turn on the light The screen will display and the status bar will display This device supports a maximum of 16 standby lights ...

Page 77: ...Operation Product manual 2TMD041800D0026 77 ...

Page 78: ...e button Tap the button to mute the ringtone on the device Tap this button again to unmute Press the button and hold for 3 s to mute the ringtone of all indoor stations in the same apartment The device will display on the status bar if the function is enabled ...

Page 79: ...us bar and select Mute timer to access the settings 2 Click or to set the value for hour and minute Click OK to save 3 Click again and select Activate mute This indoor station will mute the ringtone immediately and display on the status bar 4 When the countdown is complete the indoor station will unmute automatically and display on the status bar ...

Page 80: ...e camera should be connected to the camera interface Please refer to the following diagram 2 The camera interface needs to be associated with this device mode 4 Please refer to the product manual of camera interface 3 The function Visual doorbell should be enable before the use Please refer to the chapter Camera list CI S Camera interface mode 4 Doorbell Camera System controller ...

Page 81: ...e to block all operations during screen cleaning On the System Settings screen click Display followed by to access the screen The countdown 1 30 is displayed on the screen Any operations on the screen will be invalid This device will exit Clean screen mode if an incoming call is received ...

Page 82: ...esigned to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment ...

Page 83: ...plemented have not been compromised and system functionality in your environment is as expected Upgrading Device supports firmware updates via SD card Malware prevention solution The M2238 device is not susceptible to malware because custom code cannot be executed on the system The only way to update the software is via firmware upgrades Password rule The user must change the engineering password ...

Page 84: ...d specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 85: ...anayi Bolgesi 2 Cadde No 16 Y Dudullu Istanbul T 90 216 528 2281 F 90 216 528 2945 ABB KSA Electrical Industries Co Ltd P O Box 325841 Riyadh 11371 T 966 1 1484 5600 F 966 1 1206 7609 ABB Thailand Ltd 161 1 SG Tower 1st 4th Floor Soi Mahadlekluang 3 Rajdamri Road Lumpini Pathumwan Bangkok 10330 Thailand T 66 2 6651 000 F 66 2 6651 043 ABB Russia Ltd 3121 Wiring Accessories 30 1 bld 2 Obrucheva str...

Page 86: ...Error Use the Home tab to apply Überschrift 1 to the text that you want to appear here Product manual 2TMD041800D0026 86 Copyright 2019 ABB All rights reserved ...

Reviews: