background image

 

 

 

 

ABB AB / Jokab Safety

 Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden 

www.abb.com/jokabsafety 

Original instructions 

EStrong-series 

Emergency Stop 

 

 

Summary of Contents for EStrong Series

Page 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions EStrong series Emergency Stop...

Page 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete dete...

Page 3: ...tes 4 Special notes 4 2 Overview 5 General description 5 Safety regulations 5 Function description 5 3 Connections 6 4 Installation and maintenance 7 Installation and maintenance 7 Maintenance 7 5 App...

Page 4: ...or authorized installation personnel Prerequisites It is assumed that the reader of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safet...

Page 5: ...e instructions or standards especially when tampering with and or modifying the product any liability is excluded Function description The EStrongZ contact block configuration is a 2NC and 2NO and the...

Page 6: ...172247M0201 rev B 6 www abb com jokabsafety 2013 04 11 3 Connections See Chapter Installation and Maintenance for more information regarding installation Connections EStrongZ EstrongZ explosion proof...

Page 7: ...amp will illuminate Red When 24VDC is applied to the Green wire or Terminal 3 the lamp will illuminate Green If the LED is fitted but is not used ensure the conductors remain coiled and fixed away fro...

Page 8: ...2TLC172247M0201 rev B 8 www abb com jokabsafety 2013 04 11 5 Application examples...

Page 9: ...2TLC172247M0201 rev B 9 www abb com jokabsafety 2013 04 11...

Page 10: ...for M4 screws NB All measurements are in mm Accessories Type Article number Description Gland 2TLA050040R0002 Stainless steel cable gland M20 x 1 5 Conduit Plug 2TLA050040R0004 Stainless steel condui...

Page 11: ...urrent lth 10 A Rated insulation withstand voltages 500 VAC 2500 VAC Short circuit overload protection Fuse externally 10 A FF Explosion Proof version X Classification Ex d IIC T6 20 C Ta 60 C Gb Ex t...

Page 12: ...PL e cat 4 depending on system architecture EN 62061 Up to SIL3 depending on system architecture Safety data Mechanical reliability B10d PFHD Proof test interval life MTTFd 1 500 000 operations at 10...

Page 13: ...2TLC172247M0201 rev B 13 www abb com jokabsafety 2013 04 11 8 EC Declaration of conformity...

Page 14: ...2TLC172247M0201 rev B 14 www abb com jokabsafety 2013 04 11 ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety...

Reviews: