background image

3

Introduction

4

Principle of operation

5–12

System – Surveillance Areas

13–14

Special features of the 

15–19

Busch Watchdog Professional/Alarmtech

Interference factors

20–21

Fields of application

22–23

Installation

24–27

Product features/product overview

28–31

Busch Watchdog range

32–35

Examples of typical circuits

36–43

Troubleshooting

44–46

Table of contents

Summary of Contents for Busch Watchdog 180 UPComfort II

Page 1: ...ecial features of the 15 19 Busch Watchdog Professional Alarmtech Interference factors 20 21 Fields of application 22 23 Installation 24 27 Product features product overview 28 31 Busch Watchdog range 32 35 Examples of typical circuits 36 43 Troubleshooting 44 46 Table of contents ...

Page 2: ...egisters invis ible infrared heat radiation If the registered energy pattern changes as the result of movement a pulse is activated The strength of the pulse depends on the intensity of the infrared radiation and on its direction of movement Introduction Principle of operation The Busch Watchdog is purely a receiver and trans mits no signals itself The connection between the heat source and the Bu...

Page 3: ... area i e the colder the outside temperature and the more intensive the radiation of the detected body the larger the sensor signal The Busch Watchdog reacts to large rapid changes in temperature Slow temper ature changes and constant temperatures such as the cooling of a car engine do not activate the device If a person moves directly towards the sensor the increase in heat intensity is slow and ...

Page 4: ...perfectly to the ambient conditions the following variables are externally adjustable Operating modes With the operating mode selector the numerous functions of the Busch Watchdog Professional 220 280 and Alarmtech 220 can be selected easily and clearly Time setting Specifies the delay time during which the light remains on after the sur veillance zone is vacated In addition to the exact time sett...

Page 5: ...n zone is determined mainly by the number of lens segments and their optical design The available range depends on the size of the lens segments optical magnification and the electrical amplification factor The lens system of the Busch Watchdog which is permanently connected to the sensor housing to provide a good seal for the unit has an exceptionally high reso lution for movement detectors The p...

Page 6: ...Short time pulse e g for staircase timer switch Precise digital time and dusk setting Selectable comfort and vacation mode Continuous light through break switch Intelligent alarm function separate surveillance zone 220 90 280 The detection angle Additional protection for windows and doors up to the wall of the house even in case of installation directly above doors and windows is provided by the i...

Page 7: ...nal 90 Busch Watchdog Alarmtech 220 BuschWatchdogProfessional220 BuschWatchdogProfessional220EIB Busch Watchdog Professional 280 Rearfield detection Rearfield detection Rearfield detection Security zone up to 6 m Range up to 16 m Range up to 16 m Range up to 16 m In addition to the basic functions the Busch Watchdog Professional offers numerous advantages in day to day operation The various detect...

Page 8: ...ge of the security zone is about six metres to the front and to both sides If someone enters this inner zone the red warning light is activated can be switched off with the optional remote control and a signal applied to an additional output which can be used for example to activate a second light or another signalling device Remote control The main functions can be controlled with a hand held inf...

Page 9: ...To allow the connection of high loads without needing an additional auxiliary relay high capacity relays have been used which guarantees a long service life of the unit Test function To simplify adjustment during installation the delay time is set to two seconds in the Test position The dusk sensor is then disabled Once the desired setting has been found after testing the settings select the desir...

Page 10: ... off can also activate a movement detector This can be pre vented by using surge volt age protectors or a special RC element For further information about this see the troubleshooting section Range fluctuations In extreme weather condi tions the size of the detec tion zone may change High outside temperatures and poor visual conditions due to fog rain or snow can tem porarily reduce the range Exce...

Page 11: ...rd Comfort II Applications Corridors hallways Outdoors Hallways corridors cellars changing terraces cellars libraries rooms rest loading ramps offices rooms loading bays showrooms buildings outdoor areas garages terraces etc Private house Administrative buildings Hotels Schools Sports facilities Industrial buildings Multi storey car parks basement garages Shops Transportation companies Car parks H...

Page 12: ...imum distance between the Busch Watchdog and the switched lights is 1 5 m The temperature change of a light installed near the sensor could otherwise cause the sensor to re activate after it has been switched off Spotlights should not be aimed directly at the Busch Watchdog 6 The range to the front can be adjusted by turning and tilting the sensor part and to the side by partially covering the len...

Page 13: ...of overhangs canopies balconies The devices can be pre pared for the respective mounting position by simply rotating the sensor housing Again the adjust ment screws must point downwards after instal lation Important Observe correct installation height approx 2 5 m 10 Installation in lighting control systems The detection zone must be adapted to the local conditions For instal lation for example in...

Page 14: ...uorescent lamps Suitable for low voltage halogen lamp Protection against water IP 55 IP 55 IP 55 IP 55 IP 55 Wall mounting Ceiling mounting Corner mounting 5 Masking strip EIB functionality Anthracite 6852 AGM 35 6878 AGM 35 6880 AGM 35 6879 AGM 35 Brown 6852 AGM 201 6878 AGM 201 6880 AGM 201 6879 AGM 201 White 6852 AGM 204 6878 AGM 204 6178 AGM 204 6880 AGM 204 6879 AGM 204 1 Separate in surveill...

Page 15: ...o the close range Mounting height Remote Near 1 2 m 10 m 2 m 2 0 m 12 m 3 m 2 5 m 15 m 3 5 m The Busch Watchdog flush mounting range Select lens Multi lens 6800 2X 104 6800 2X 104M Switch off behaviour In combination with 6593 U soft Off function the Komfort II sensor dims down and switches off within 60 seconds Comfort II Relay unit 700 W VA Three wire technology MOSFET unit 60 420 W VA Two wire ...

Page 16: ... presence indicators Busch Watchdog Professional 220 220 EIB Busch Watchdog Professional 90 Busch Watchdog Professional 280 Busch Watchdog Alarmtech 220 Busch Watchdog Comfort II Busch Watchdog Presence Detector1 1 Please ask for revised user manual ...

Page 17: ...35 34 Corner adapter RC element Surface mounting enclosure for Busch Watchdog Presence Detector Special equipment accessories ...

Page 18: ... switch to PERMANENTLY ON or Busch Watchdog mode Switch with neon indicator for switching over to PERMANENTLY ON In Busch Watchdog operation the control lamp signals that the connected light has been switched on status signal Busch Watchdog Alarmtech 220 switched on through a push switch If the power supply of the Busch Watchdog Alarmtech 220 is intermittently interrupted in standby mode and then ...

Page 19: ...n external relay contactor for use with floating make and break contacts to increase the switching capacity to more than 2300 W 3500 W Parallel operation of several Busch Watchdogs for example in conjunction with a push switch for several sides of the house Operating mode selection with two circuit switch Functions 1 I On II On Off continuous light without Busch Watchdog function 2 I Off II Off sy...

Page 20: ...the power supply of the Busch Watchdog is intermittently interrupted in standby mode and then reconnected the lights are switched on automatically for the set delay time When you press the push switch twice the light is switched on for four hours Extension of the Off delay or actuation of a pulse relay e g for flashing lights Busch Watchdog with staircase light timer switch Busch Watchdog in short...

Page 21: ...with a 6401 U 102 master unit Examples of circuits UP Activating the Busch WatchdogUP 180 6401 U 10x 6804 U 6593 U with a push switch When the switch is operated the Watchdog is automatically switched on for the specified time for example for staircase time switches For illumi nated switches a separate N is required Neutral conductor is required for the 6401 U 10x Activating the Busch WatchdogUP 1...

Page 22: ...on Light is always on Fault Automatic undesired switching Light continuously switches on and off by itself Possible cause remedy Switch on after power failure wait Sunlight or heat reflection readjust area detection or use shutter Sudden temperature change storm rain snow fans etc in the surveillance zone Readjust surveillance zone or select more pro tected mounting location Animals in the detecti...

Page 23: ...47 46 Fault Watchdog does not respond to changes at the dusk sensor Possible cause remedy Watchdog is operating in dazzleproof mode normal Notes ...

Page 24: ...ngford Road Exhall Coventry CV7 9ND Tel 02476 368500 Fax 02476 368401 e mail marketing info gb abb com www abb co uk A new generation of ABB Busch Watchdogs Installation guide A new level of security Seeing everything and being seen ...