Publication 2727-QS002E-MU-P

Quick Start

MobileView Guard G750

(Catalog Number 2727-G7P20D1P4, -G7P20D1P5, -G7P20D1Q6, -G7P20D3Q7)

Inside . . .

English..................................................................................................................................3
Français 
.............................................................................................................................. 35
Deutsch 
.............................................................................................................................. 69
Español
.............................................................................................................................103
Italiano 
.............................................................................................................................137
Português 
.........................................................................................................................169

Summary of Contents for 2727-G7P20D1P4

Page 1: ...Publication 2727 QS002E MU P Quick Start MobileView Guard G750 Catalog Number 2727 G7P20D1P4 G7P20D1P5 G7P20D1Q6 G7P20D3Q7 Inside English 3 Français 35 Deutsch 69 Español 103 Italiano 137 Português 169 ...

Page 2: ...Publication 2727 QS002E MU P ...

Page 3: ...om Inside Important User Information 4 MobileView Guard G750 Description 5 Safety Precautions and Elements 6 MobileView Junction Box Mounting and Wiring 12 Removing the Back Cover 19 Ethernet Connection 21 Using the PC Card Slot 21 Startup Power On 24 Hardware Configuration 25 Ethernet Network Configuration 25 Saving Registry Settings 27 Starting Terminal Services 27 Shutdown Power Off 28 Mounting...

Page 4: ...blication Allen Bradley publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Allen Bradley office describes some important differences between solid state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication Reproduction of...

Page 5: ...witch option 7 Illuminated momentary push button normally open ON marking yellow LED option 8 7 7 inch VGA 640 x 480 pixels passive matrix color LCD display with analog resistive touch screen 9 3 position twin circuit enabling switch one each side of handle for safety system interface 10 IrDA keyboard printer interface 9600 or 115 2K baud 11 Handle for left or right hand operation 12 Single slot P...

Page 6: ...xternal safety measures to ensure the system remains in a safe operating condition Make sure unauthorized persons are not allowed to adjust settings or make memory modifications that could lead to dangerous situations Test the functionality of safety related parts E stop and enabling switches on a regular basis If the MobileView terminal and controller do not communicate using a point to point con...

Page 7: ...used to maintain the normal operating mode ATTENTION The device meets safety class III in accordance with EN 61131 2 and EN 50178 The 24V power supply for the equipment must provide appropriate isolation between safety extra low voltage circuits and dangerous contact voltage circuits for example by safety transformers or similar facilities Protect the power supply circuit with a 3 15 A fuse The no...

Page 8: ...s 1 and 3 of the enabling switch are OFF functions Only the central position is used for enabling The EN 60204 1 is identical with IEC 60204 1 So the 3 position enabling switch is of international relevance The enabling switch consists of a 3 position operating element and separated evaluation electronics Essential features are the continuous two channel circuits between the actuating elements and...

Page 9: ... 2 3 1 2 3 3 2 1 3 2 1 ZT1L ZT2L ZT1R ZT2R DC DC converter 6 7 6 7 S19 K3 7 8 12 17 K1 1 2 K1 7 8 12 17 1 2 24V GND E D1 E D1 E D2 E D2 X1 X2 24V GND E D1 E D1 E D2 E D2 K4 K3 E valuation electronics C ircuit 1 C ircuit 2 ZTxy enabling switch xy F eedback control loop C ontrol cabinet Connection cable MobileView 17 pin coinvers jack Intermediate cable MobileView Terminal block socket K3 on connect...

Page 10: ... which cause the machine to stop in manual mode Inquiry of the enabling switch when turning on the machine plant and inquiry of the enabling switch when changing the operating mode from automatic to manual The enabling switch must not be in the enabling position The enabling switch must be released within a defined period of time and pushed into the enabling position again The length of time must ...

Page 11: ...lated parts of control systems ANSI RIA 15 06 1999 American National Standard for Industrial Robots and Robot Systems Safety Requirements Section 9 ANSI B11 TR3 2000 Risk Assessment and Risk Reduction A guide to estimate evaluate and reduce risks associated with machine tools The safety categories B 1 2 3 4 define the structure of safety related parts of a machine and are derived from this risk as...

Page 12: ...ower supply emergency stop switch enabling switches ATTENTION The Junction Box and the MobileView terminal meet the safety class III in accordance with EN 61131 2 and EN 50178 When connecting the terminal make sure all voltages connected to the MobileView terminal are safety extra low voltages by using a safety transformer or a similar facility 24V DC ON LY TERM I NAL I N RS422 OUT ETHERNET O UT 2...

Page 13: ... on a DIN rail 1 Mount the DIN rail 2 Hook the top slot over the DIN rail 3 While pressing the Junction Box against the rail snap the Junction Box into position To remove your Junction Box from the DIN rail 1 Place a screwdriver in the DIN rail latch at the bottom of the Junction Box 2 Holding the Junction Box pry downward on the latch until the Junction Box is released from the DIN rail ...

Page 14: ...K3 10 Base T Connection to Ethernet Network Safety Equipment Connections Typical Control Cabinet maximum wall thickness 5 mm 0 2 in MobileView Terminal Junction Box Connector Cutout 25 0 1 mm 1 0 0 0039 in 0 94 in MobileView Connection Cable Dust Cover X2 K4 Use Grounding Screw to Connect Earth Ground to the Junction Box Pin 1 24V dc Junction Box Cable Pin 1 24V dc S1 S2 S3 K1 MobileView Terminal ...

Page 15: ...rc 1 neg Enable sw circ 2 pos Enable sw circ 2 neg Not used Not used TD TD RD RD pink black green brown white green grey pink red blue brown yellow green grey violet blue white orange red MobileView Connection Cable MobileView Junction Box Cable Junction Box MobileView pink black green brown white green grey pink red blue brown yellow green grey violet blue white orange red To Ethernet Network 24V...

Page 16: ...equipment must provide appropriate isolation between the safety extra low voltage circuits and dangerous contact voltage circuits for example by safety transformers or similar facilities The power supply circuit must be protected with a 3 15 A fuse The nominal supply voltage directly of the MobileView terminal without the MobileView Connection Cable is 24V dc supply voltage range 18 to 32V dc Typi...

Page 17: ...brown 8 E stop circuit 1 positive 4 white green 9 E stop circuit 1 negative 5 grey pink 10 E stop circuit 2 positive 6 red blue 11 E stop circuit 2 negative 7 brown 1 Enabling switch circuit 1 positive 8 yellow 2 Enabling switch circuit 1 negative 12 green 3 Enabling switch circuit 2 positive 17 grey 4 Enabling switch circuit 2 negative 9 bridge to pin 10 Not Used 10 bridge to pin 9 Not Used 11 vi...

Page 18: ... 3 E stop circuit 1 positive 4 white green 4 E stop circuit 1 negative 5 grey pink 5 E stop circuit 2 positive 6 red blue 6 E stop circuit 2 negative 7 brown 7 Enabling switch circuit 1 positive 8 yellow 8 Enabling switch circuit 1 negative 12 green 9 Enabling switch circuit 2 positive 17 grey 10 Enabling switch circuit 2 negative 9 Not Used 10 12 Not Used 11 violet 11 Not Used 13 blue 1 TD transm...

Page 19: ... the MobileView terminal Once the back cover is removed you have access to the area which contains all of the connectors 1 Place the terminal on a stable flat surface 2 Remove the 6 screws that secure the back cover to the terminal 3 Carefully lift off the back cover and set aside ATTENTION Turn off the power supply before removing the back cover of the MobileView terminal When the back cover is r...

Page 20: ...n Cable outlet Main connector S19 for power supply and control lines Ethernet connector S4 for data exchange Position of switches does not affect terminal operation for future use Strain Relief for connecting MobileView Connection Cable on left or right side Ethernet Label Ethernet Mac Address Cable Tag Allows the terminal to be uniquely identified Connector not used pin 1 S19 S4 S6 C OM M odul S6...