background image

www.go4b.com

Binswitch Elite

CAPACITANCE POINT LEVEL SENSOR
PULSED OUTPUT VERSION

INSTALLATION INSTRUCTIONS

OPERATION MANUAL

Part No. BSE12V10AI/x/BP3

Summary of Contents for Binswitch Elite

Page 1: ...www go4b com Binswitch Elite CAPACITANCE POINT LEVEL SENSOR PULSED OUTPUT VERSION INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No BSE12V10AI x BP3...

Page 2: ...e 5 APPROVALS Page 6 DIMENSIONS Page 6 INSTALLATION Page 7 SPECIFIC CONDITIONS OF USE Page 7 WIRING DIAGRAMS Page 8 SENSOR OPERATION CALIBRATION Page 9 TESTING COMMISSIONING Page 10 TROUBLESHOOTING GU...

Page 3: ...esponsibility of the user unless you have asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to...

Page 4: ...ction work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install...

Page 5: ...ting capacitance change when material is present Please see Sensor Operation and Calbiration section for more details WARNING Always lockout and tagout machinery prior to installation PAGE 5 SPECIFICA...

Page 6: ...15X 1G Ex ma IIC T4 Ga 1D Ex ma IIIC T200 110 C Da Tamb 15 C to 50 C IP66 EACEx RU C GB A 07 B 02815 20 0 Ex ma IIC T4 Ga X Ex ma IIIC T200110 C Da X OT 15 o 50 IP66 CCC CQC 2020012315348849 Ex maD A2...

Page 7: ...hod is available figure A below PAGE 7 Fig A Cut and drill holes as shown and attach brasion shield BAS3 using four M6 bolts Slide Binswitch into position and secure with a clip and cover part of the...

Page 8: ...RING DIAGRAMS All wiring must be In accordance with local and national electrical codes and should be undertaken by an experienced and qualified electrician PAGE 8 NOTE This device is 24VDC supply onl...

Page 9: ...shing in a sequence 3 times every 4 seconds Device Configuration The devices zero offset calibration can be set This operation tells the device what the default level of capacitance in a given applica...

Page 10: ...pulse will occur when material has been detected WARNING If the system does not immediately shutdown as expected or alarm as required then remove the machine from service until the problem has been di...

Page 11: ...se or misapplications as authorized by law 4B specifically disclaims all warranties that the product is fit or merchantable for a particular purpose 3 NO WARRANTY BY SAMPLE OR EXAMPLE Although 4B has...

Page 12: ...41 Bellrick Street Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3216 9365 Fax 61 0 7 3219 5837 4B COMPONENTS LTD 625 Erie Avenue Morton IL 61550 USA Tel 309 698 5611 Fax 309 698 5615 4B BRAIME C...

Reviews: