background image

 

 

 

 

2.4GHzWireless Digital Microscope 

 

 

 

                                                       

Comprehensive Operating Instruction   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Anyty

Page 1: ...2 4GHzWireless Digital Microscope Comprehensive Operating Instruction...

Page 2: ...hich have been filmed by Anyty VIEW 30 P11 Spec 31 Manual of Anyty Series TV Model T1 How to charge Anyty Digital Microscope and LCD Monitor 32 T2 Switch on and Channel Harmonization 34 T3 Simple use...

Page 3: ...ly at LED light source It could damage your Visual Acuity AVOIDING touching with wet hands DO NOT use the product with wet hands or the product in wet conditions It could lead to electric shock Decomm...

Page 4: ...cessories in Microscope of magnification x 200 C Accessories in Microscope of magnification x 600 D Accessories in PC Model E Accessories in TV Model Operating Instruction This book Dedicated Case Mod...

Page 5: ...PC TV Model 3R WM401PCTV A B D E 6 2 4GHz Wireless Digital Microscope Set of Magnification x 600 PC TV Model 3R WM601PCTV A C D E 7 2 4GHz Wireless Digital Microscope Magnification of x 200 600 PCMod...

Page 6: ...could last for 5 hours in full power condition Attention USB Charging Cable is for Microscope ONLY DO NOT use ANY other charging cable on it Charging Connector Charging Connector is on back of Micros...

Page 7: ...wsXPSP2 Vista Only for 32 bit CPU CPU above Pentium 600Mhz Optics Drive Essential Memory 256MB or more of Physical Memory Save Area 100MB or more HD space Connection Method USB1 1 2 0 Display Space 15...

Page 8: ...connect Receiver to PC until installation is complete Please press Continue if User Account Control UAC is activated Insert Software CD into CD ROM The option will be shown as below if auto play is ac...

Page 9: ...en set up program is activated Choose Install Software 32bit or Install Software 64bit on the basis of your PC specs Please see 49 page to confirm your PC spec 32bit or 64bit The image will be shown o...

Page 10: ...License Agreement will be shown To continue installation please tick I accept Then click Next You could choose which folder to save it at next screen Normally click Next to start program installation...

Page 11: ...Receiver to USB port on PC with miniUSB cable Windows will detect the device automatically Installation will be done when the message shows as below The name will be shown in Device Manager as images...

Page 12: ...11 During the Device installation please press Install this driver software anyway to continue installation...

Page 13: ...us at inquiry 3rrr co jp In case of using Windows8 32bit version to install insert install CD into CD ROM Then click the icon of computer on Desktop so the explorer will be shown Thirdly open click C...

Page 14: ...p of use will be showing below Connect Receiver to PC and tune the channel Install a lens cover and turn the power on Launch software Anyty VIEW Adjust luminance of LED and Magnification dial As you p...

Page 15: ...1 2 3 4 Switch of Channel Channel of 1 2 3 4 2 Then adjust the switch on Anyty Wireless Microscope as same number as on Receiver Switch of Channel Channel of 1 2 3 4 3 Once the channel has been tuned...

Page 16: ...on when you take picture It will be the right focal length as the lens cover and object touch each other Trimming could be done with Magnification dial 2 To shoot under untouched and unknown magnifica...

Page 17: ...m and Desktop In some case icon would not be established on desktop Desktop icon Double click to launch Anyty VIEW You are also able to open it from Start All Program 3R Anyty VIEW 40101 Please left c...

Page 18: ...still picture Filming Stop Continuous shooting of still picture Attach to E mail Save Thumbnail of image and movie Icon of summary of image movie Data of image and movie will be shown as thumbnail on...

Page 19: ...ile through using Save icon No frame Taking still picture Three ways of taking still picture Press icon on tool bar Press keyboard button F2 Press round button on Microscope Image data will be saved i...

Page 20: ...ly please use it under default condition Reference Analogue TV Approx 30 fps Movies on Mobile phone 15 24fps Time limit Check the box to set filming time in seconds and stop filming automatically Clic...

Page 21: ...ne in time you have set after current shooting Capture Set how many pictures you want to take and save File size It shows the size of pictures based on your settings Attach to Email Select thumbnail o...

Page 22: ...or make it display scales Capture Contains the same functions of icons on the Main Window Taking still picture or filming movie and taking Continuous picture Help Display the software version and our...

Page 23: ...ngs Cross line Display a cross line at the center of screen Scale Display scale horizontally and vertically It will overlap cross line Dial gauge will not change due to change of magnification Circle...

Page 24: ...magnification dial gauge and the number printed on lens cover to enter the measuring function will calculate the data automatically based on figure in the blank go to page 26 See Magnification dial g...

Page 25: ...u bar are for measuring Each icon has its specific measurement method Icons of measurement Operation of Measurement functions e g Linear size Click the icon on menu bar Measurement of Linear size Nega...

Page 26: ...part of the L when you want to measure height of it Click twice at the point of red arrow At last click anywhere you want to display the value It will be displayed Please click Save icon to save the...

Page 27: ...ome specific measurement Additions and Corrections Use Additions and Corrections to calculate more accurate value Steps are shown below First capture attached simple scale ore micro meter with Microsc...

Page 28: ...ewal the measurement or delete it please click the icon at right side of correction icon Click Undo to delete previous measurement Also click Delete All to delete all value you have entered Pen settin...

Page 29: ...med picture which are captured by Anyty VIEW only Save You are able to save the picture as another name after editing Paint You are able to paint line and figure in picture Measure Enter magnification...

Page 30: ...do Enter magnification at capture period You must do this when you measure size Calibration Use this to improve accuracy of measurement To understand control step please see page 26 Change font of tex...

Page 31: ...30 P10 Playing captured movies with Anyty Double click the movies you have captured in main window to open movie player and start playing it...

Page 32: ...2 4Ghz wireless channels Transmitter receiver Transmission distance Approx 5m PC interface receiver USB 2 0 1 1 Magnification x200 x10 200 15 inch LCD screen Magnification x600 x450 600 15 inch LCD sc...

Page 33: ...ring charging period dial switch flashes blue Charging period will be approx 3 hours Maximum 5 hours of working time in full power condition Attention USB charging cable is specialized to Microscope P...

Page 34: ...e charging is complete Charging time will be about 3 hours It lasts about maximum 2hours in full power condition Attention AC adaptor is only for LCD Monitor Please DO NOT use it on Microscope It coul...

Page 35: ...irm that the MicroSD card is inserted properly Then choose one of four channels After tuning turn the dial switch right on the Microscope until it sounds click to turn on the power Dial switch Dual pu...

Page 36: ...l shows screen as described below Channel will be shown on top right side of the screen Radio Channel Press button to do the tuning in case of mismatching channel button Setting is complete if the pic...

Page 37: ...Setting menu will be displayed Select SYSTEM SETTING with button and press OK to confirm Each setting will be displayed Select Language with button and press OK to confirm The language will be set Se...

Page 38: ...ore details about operation steps Turn the both power of Microscope and LCD monitor on Load lens cover and adjust magnification and focal point Press button on the monitor to select image movie to cap...

Page 39: ...figure of magnification when you take picture It will be the right focal length as the lens cover and object touch each other Trimming could be done with Magnification dial 2 To shoot under untouched...

Page 40: ...f LCD Monitor first and press button It will be still picture mode Saving still picture Press OK button at left side of the LCD monitor in Saving Still Picture Mode to save current screen The icon of...

Page 41: ...f the LCD monitor in Movie capture mode and recording will be starting During capturing period a round icon at top of the screen will flash Capturing time will be shown at bottom right side of the scr...

Page 42: ...Press button to select and OK to confirm Then the index of selected file will be shown Press to choose Data of what you want to view and press OK to confirm Difference between Image Movie data Data wi...

Page 43: ...42 Preview of movies Press OK to play the movie Halt Press OK when the movie is playing Forwarding Press when the movie is playing Rewind Press when the movie is playing End Press to end...

Page 44: ...43 T8 Delete images movies Select the file that you want to delete with button Then press button for 2 seconds It will ask you if you confirm Select Yes and press OK to delete the file...

Page 45: ...ally unnecessary to change from NTSC to another Select SYSTEM SETTING in setting menu Select Video System Select one from NTSC and PAL and press OK to confirm Formatting All data in SD card will be de...

Page 46: ...from 10 to 30fps Time stamp Changing having time stamp or not Select RECORDER SETTING in setting menu Select Time Stamp Select one from ON OFF and press OK to confirm Capturing type You are also able...

Page 47: ...f the internal date and time Select Date Time in setting menu Set Year month day and Hours Use Up and Down button to change value and move to the next item by the Confirm button Push the menu button i...

Page 48: ...Monitor on TV Please connect picture input of TV to the picture output of the LCD monitor with an attached video cable A picture will be output to TV without a screen being displayed when you switch o...

Page 49: ...ed it with a attached monitor of the TV model will be different Thank you for your understanding beforehand LCD 3 5 inches TFT LC Resolution 320 240 Video format PAL NTSC Frequency 2414MHz 2432MHz 245...

Page 50: ...the microscope it may have an influence on operation of the microscope E When you could not operate an LCD monitor in TV model please push the reset button of the backside with a former thin thing and...

Page 51: ...50 Manufactured and sold by 3R SYSTEMS CORP HQ No 5 8 11 Naka Hakata ku Fukuoka City Japan Official website 81 92 441 4056 81 92 441 4077...

Reviews: