background image

CPR

Lilly

 P70 

(1017772)

 

CPR

Lilly

PRO

 P71 

(1017773)

CPR

Lilly

 P70/1 

(1017774)

 

CPR

Lilly

PRO

 P71/1 

(1017775)

 

1

Summary of Contents for CPRLilly P70

Page 1: ...CPRLilly P70 1017772 CPRLillyPRO P71 1017773 CPRLilly P70 1 1017774 CPRLillyPRO P71 1 1017775 1 ...

Page 2: ...ontents 3 Quick introduction 4 Assembly start up and use 5 Simulations 6 Medical procedures 14 General safety instructions 16 FAQ 16 Maintenance and care 17 Replacement parts list 18 Technical data 19 CPRLilly P70 und CPRLillyPRO P71 2 ...

Page 3: ...Resuscitator ventilation is possible Realistic thoracic spring force and the required compression depth of 5 cm prepare the trainee for a situation with a real person A sound indicates that the required compression depth has been reached Thanks to the disposable respiration bags the mannequin is hygienic and is easy to clean and maintain CPRLilly and CPRLillyPRO have two respiratory systems that a...

Page 4: ...Quick Introduction 4 3B Scientific GmbH Rudorffweg 8 21031 Hamburg www 3bscientific com P70 CPRLilly P70 1 CPRLilly P71 CPRLillyPRO P71 1 CPRLillyPRO ...

Page 5: ...battery is fully charged Version P71 To avoid getting moisture into the inner circulation respiration may only be carried out when a throat bag has been inserted The throat bag should not be changed in the rain because water could get into the inner circulation The CPRLilly and CPRLillyPRO could get damaged When being used noises will be heard version P71 This does not mean that the simulator is n...

Page 6: ...d If you intend to not use the device for an extended period charge the battery up completely until the LED flashes orange slowly Changing the battery The CPRLillyPRO has a very long life NiMH battery that only discharges very slowly It should only be changed by a specia list or an authorised electrician You can order a replacement battery from the accessory list if necessary The instructions for ...

Page 7: ... initial set up the app is automtically set to English Once the tablet has booted up the select dialogue box for the language of the application software is displayed on the touch sensitive screen To change language select Settings then Language 3 2 Function menu The following application notification is displayed The heart turns red when a connection to CPRLillyPRO exists The connection display i...

Page 8: ... simulation 3 3 Setting up removing a Bluetooth connection To connect another CPRLillyPRO Bluetooth can be deleted or set up again via the Settings function Only one CPRLillyPRO can be connected to the tablet at a time 8 ...

Page 9: ...9 ...

Page 10: ...ting the graphs 3 5 Exporting the data It is only possible to export data if the CPRLillyPRO is switched off and or the Bluetooth connection has been deactivated If CPRLillyPRO is connected the Print icon is deactivated 10 ...

Page 11: ...llocated 0 points If more than 2 ventilations per cycle are made the additional ventilations will not be assessed Pressure If fewer than 2 ventilations per cycle are made the remainder will be allocated 0 points If more than 2 ventilations per cycle are made the additional ventilations will not be assessed green in mm in lower limit 50 83 upper limit lower yellow green upper yellow in BPM in BPM i...

Page 12: ...essment may show a yellow symbol for the head tilt regardless of the mean over the simulation round red yellow green 50 50 80 Hand placement Depending on the compressions Richtig green wrong red Instead of the metronome the song Stayin alive can be selected In online mode the firmware versions of the CPRLillyPRO can be queried via the tablet They are not visible unless a doll is connected 12 ...

Page 13: ...tablet If you have a P70 please connect two squeeze balls to the connectors for eye blinking and pulse By compressing the balls you can control the pulse and eye blinking as a trainer To control the pulse and eye blinking via the software please activate the learning mode using the Settings and General menus The pulse can be adjusted with the white squeeze ball P70 or via the software P71 13 ...

Page 14: ...e mouth of the CPRLilly or the CPRLillyPRO Even semi liquid foreign bodies such as shaving foams can and should be introduced for practice purposes They can then be thrown away with the throat bag Important Sharp foreign bodies or removing items with sharp foreign bodies are not permitted The respiratory system of CPRLilly or CPRLillyPRO would be damaged by this 3 Artificial respiration 14 ...

Page 15: ...d the silence button You can find this in the simulator window if the teaching mode has been activated What do the colours on the LED button mean green light The CPRLillyPRO is switched on and ready for use no light CPRLillyPRO is switched off green red flashing light the battery is almost flat flashing slowly orange the battery is charged flashing quickly orange the battery is being charged flash...

Page 16: ...ways airbag also ensure that using the device is especially hygienic Please do not use any harsh chemicals for cleaning because they can damage the model materials The upper skin of the CPRLilly or the CPRLillyPRO may if severely soiled be cleaned in a washing machine without the spin cycle e g using the wool programme at a maximum of 40 C with usual washing products The rest of the surface of the...

Page 17: ...9 Throat bag pack of 50 1017743 Throat bag pack of 100 1017744 Carry bag 1017746 Tracksuit top 1013678 Resuscitator 1017747 Torso skin light 1017766 Torso skin dark 1017748 Bag clip 1017749 Lower jaw 1017758 Eyes light pair 1017767 Eyes dark pair 1017759 Eye rings pair light 1017778 Eye rings pair dark 1017750 Squeeze ball light blue 1017751 Squeeze ball white Replacement part orders 17 ...

Page 18: ...device class III Operating conditions CPRLilly and CPRLillyPRO are splash proof protection class IP 45 Operating temperature 10 C to 40 C Storage temperature 20 C to 60 C The plastics used meet the requirements of the DIN EN 71 3 9 Toy Safety Directive The CPRLilly and CPRLillyPRO are designed for use outdoors and can therefore also be used outside 18 ...

Page 19: ... i d e g r o u p o f c o m p a n i e s 3B Scientific P70 1017772 P70 1 1017774 P71 1017773 P71 1 1017775 v1 1 08 2015 Copyright for instruction manual and design of product 2015 3B Scientific GmbH Hamburg Germany 19 ...

Reviews: