background image

www.2n.cz

2N SIP Mic

Microphone console

Configuration Manual

 

Firmware:

 

Version:

1.0

Summary of Contents for Sip mic

Page 1: ...www 2n cz 2N SIP Mic Microphone console Configuration Manual Firmware Version 1 0 ...

Page 2: ...rademarks and or trademarks or brands protected by law 2N TELEKOMUNIKACE a s administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services On www faq 2n cz you can find information regarding products adjustment and instructions for optimum use and procedures What to do if 2N TELEKOMUNIKACE a s hereby declares that the 2N product compl...

Page 3: ...d Use 3 1 Configuration 3 1 1 System Status 3 1 2 Network 3 1 3 VoIP 3 1 4 Audio 3 1 5 Buttons 3 1 6 Zones 3 1 7 Action Scheduler 3 1 8 System 3 1 9 Voice Messages 3 2 Setting Examples 3 2 1 Express Settings 3 2 2 Announce to Zone VAPIX 3 2 3 Voice Message Loading 3 2 4 HTTP Request 3 3 Downloads 4 Technical Parameters 5 Supplementary Information 5 1 Troubleshooting 5 2 Directives Laws and Regulat...

Page 4: ...2N TELEKOMUNIKACE a s www 2n cz 4 76 1 Product Overview Here is what you can find in this section 1 1 Components and Associated Products 1 2 Terms and Symbols ...

Page 5: ...hat For example it can accept calls from the 2N intercoms listen to the zone traffic schedule announcements and or load own messages This makes it an ideal solution for places where identical announcements are played several times a day such as schools amusement parks stores or public transport terminals Easy power supply via PoE and programming via a web interface are additional bonuses With inte...

Page 6: ...r VAPIX support Easy control Easy one cable installation Ethernet PoE VoIP PBX support SIP Remote control via DTMF or HTTP commands Integrated administration web server Streamed audio support Applicable as a standard VoIP phone communicator DTMF detection according to RFC2833 in band and SIP INFO ...

Page 7: ...akers and top quality microphone in package Caution This product its installation and configuration are not intended for persons with physical sensory or mental disabilities or persons with limited experience and skills unless expert supervision or relevant instructions are provided to them by a person responsible for their safety ...

Page 8: ...2N TELEKOMUNIKACE a s www 2n cz 8 76 1 1 Components and Associated Products Main Unit Part No 914431E 2N SIP Mic ...

Page 9: ...EU cable PoE injector with US cable For power supply of intercom via ethernet cable when PoE switch is not available Part No 914102x Stabilised 12 V 2 A power supply E Europe GB Great Britain US USA needs to be used when no PoE is available Tip For more accessories and particular advice please contact your local distributor of 2N products ...

Page 10: ...al Safety Always abide by this information to prevent persons from injury Warning Always abide by this information to prevent damage to the device Caution Important information for system functionality Tip Useful information for quick and efficient functionality Note Routines or advice for efficient use of the device ...

Page 11: ...2N TELEKOMUNIKACE a s www 2n cz 11 76 2 Description and Installation Here is what you can find in this section 2 1 Before You Start 2 2 Electric Installation 2 3 Product Description ...

Page 12: ...eteness Check Before installing this product check whether the product delivery includes 1x 2N SIP Mic Quick User Manual Installation Conditions 2N SIP Mic is to be connected to the LAN 2N SIP Mic is designed for indoor use 2N SIP Mic may not be operated in damp environment ...

Page 13: ...pper connector connect the UTP cable connect a 12 V power supply to the back connector unless PoE is used Caution Be sure to connect the power supply as the last step The SIP 2N Mic same applies to PoE supply from the LAN The device must be part of the electrical system of the building Insert the enclosed microphone into the DIN 3P connector on the upper 2N SIP Mic side until its clicks into posit...

Page 14: ...ection SIP Mic 2N can be connected to a standard local area network using a LAN interface via the RJ 45 connector on the back panel Always use CAT 5d or higher class cables for reliability reasons The interface supports 1 0 100 Mbps and can be PoE supplied IEEE 802 3af ...

Page 15: ... use of a LAN surge protection Power Supply Connection SIP Mic 2N can be fed using active network elements or PoE injectors via the LAN interface In case this option is unavailable use a 12 V DC 2 A Part No 914102E power supply or another power supply on condition that you keep the nominal values 12 30 V DC included in the Mechanical and Electrical Parameters subsection External and PoE supplies c...

Page 16: ...h different power supplies 2N SIP Mic Power supply Consumption PoE IEEE 802 3af 8 W 12 V 2 A 25 W Warning If you use an adapter other than the recommended one do not exceed the nominal supply voltage value of 30 V Also make sure that the supply voltage polarity is correct Exceeding nominal values and or incorrect connection may lead to irreversible damage of the equipment ...

Page 17: ...stribution 2N SIP Mic 2N SIP can be connected to a SIP Proxy and communicate with the server via phone calls Mic This guarantees compatibility with all the supported SIP based systems Use an integrated web interface for configuration Apply the 2N SIP Mic 2N to search all the units connected Network Scanner 2N SIP Mic ...

Page 18: ...6 Control Layout Controls 2N SIP Mic Legend call answer mute button A call extension button B function buttons 1 to 12 for playing announcing to zone C bar graph microphone drive indicator D microphone DIN connector E integrated speaker F ...

Page 19: ...s See below Call pick up Mute button Colour Behaviour State Action upon press White Shining At relax None Green Flashing Incoming call ringing Answer call Green Shining Active incoming call Mute microphone White red hang up Shining Muted Turn up microphone Yellow Shining Active message recording End recording Blue Shining Active outgoing call Mute microphone ...

Page 20: ...ng End playing Blue Flashing Outgoing call ringing End call Blue Shining Active outgoing call Zone announcement End call End zone announcement Green Flashing Outgoing ALARM call ringing DTMF request None cannot be terminated End call Green Shining Outgoing ALARM call rigning DTMF request None cannot be terminated End call Pink Shining HTTP request sent Return to relax Yellow Shining Active relay c...

Page 21: ...an skip over the announcement and end the call immediately Connector Layout Connectors 2N SIP Mic Connectors and controls power on off button 12 30 V DC 2 A mains adapter connector relay output LAN 10 100BASE TX RJ 45 connector logic inputs line input 3 5 mm jack for optional external sound source connection MIC input 3 5 mm jack for optional microphone connection ...

Page 22: ...he Technical Parameters for more details Press the button on the device bottom to delete all the parameters Factory Reset including the network settings Hold the button until all the system button red lights go on Then release the button The device memory will be deleted The default network settings are as follows IP address 192 168 1 100 Network mask 255 255 255 0 ...

Page 23: ...announcements Pre recorded announcements ALARM calls with DTMF announcements HTTP HTTPS request sending Multicast listening SIP call listening in Audio playing to zone from Audio LINE IN Relay activation at call Announcement recording via microphone and announcement check Here is what you can find in this section 3 1 Configuration 3 2 Setting Examples 3 3 Downloads ...

Page 24: ... DHCP server is available in the LAN Where the DCHP server is unavailable can work in the static IP address mode Refer 2N SIP Mic to the section for configuration details Configuration 2N SIP Mic Should the device be still unavailable forgotten IP address LAN configuration change etc find the IP address using a device button IP Address Lookup Do the following to find the IP address 2N SIP Mic Conn...

Page 25: ...witch DHCP off the default IP address subnet mask and DNS server are configured as mentioned below Warning Default network settings IP address 192 168 1 100 Mask 255 255 255 0 DNS 1 192 168 1 1 Description of 2N Helios IP Network Scanner The purpose of this application is to find the dynamic IP address in the 2N SIP Mic local IP network Download the application from www 2n cz Run the installer Hel...

Page 26: ...ing the application run the 2N Helios IP Network Scanner application using the menu of the Microsoft Windows operating system Start Upon launch the application starts searching the LAN automatically for all with an assigned or statically set IP address The devices are then 2N SIP Mic listed in a table ...

Page 27: ... 2N SIP Mic button and select to open the web browser window log in to Browse and start configuring as described in the Login subsection below 2N SIP Mic Login In the web browser enter the IP address of Subsequently a login screen 2N SIP Mic will be displayed The default login username and password are as follows Username Admin Password 2n ...

Page 28: ...N Helios IP Network Scanner subsection Language Selection You can select the language using the tag menu in the right hand upper corner as shown in Figure below Language selection Start Screen The start screen is displayed whenever you log in to the web interface 2N SIP Mic Use the System status menu in the left hand upper corner of the navigation bar to return to the start screen any time Choose ...

Page 29: ...ration Menu 2N SIP Mic configuration consists of 9 main menus System status Network VoIP and each of which Audio Buttons Zones Action scheduler System Voice messages is divided into submenus see the survey below System Status line state info SIP Proxy line status operation time Operation time 2N SIP Mic lock state Lock state LAN connection settings Network device info Device real time and time zon...

Page 30: ...ate info Status Audio ringing volume and key beep settings Settings Buttons button action settings Zones zone parameter settings Action scheduler action settings System user parameters date and time Configuration configuration backup and reset firmware upgrade reboot Maintenance factory default Voice messages voice and system message settings and upload ...

Page 31: ... Mic 2N makes all outgoing SIP calls and receives incoming calls via this line The SIP Mic available options are as follows Inactive Active Registered Registration in progress and registration error The meanings are as follows Inactive The SIP line is off Active The SIP line is set in the VoIP menu but registration is not allowed Outgoing only Registered The SIP line is registered and functional O...

Page 32: ...state information Locked and Unlocked If the state is Locked no action button can be pressed on the console except for the call answer reject button and microphone muting button Click the editing icon to redirect to the System menu Network Displays the current network settings of Click the editing icon to get to 2N SIP Mic the Network menu The data is for information only Device Displays the seria...

Page 33: ...ercom IP address download the 2N Network Scanner from for free or use the mechanism described in your www 2n cz intercom s installation manual the intercom communicates the IP address to you via a voice function LAN By default the device automatically gets the IP address from the DHCP server in the LAN The current IP address is always displayed in the System status menu on the start screen If ther...

Page 34: ...ss below unless Activate DHCP is selected set the network mask IP mask default gateway address for communication with devices outside IP gateway the LAN IP DNS 1 primary DNS server address for translation of domain names to IP addresses IP DNS 2 secondary DNS server to be used where the primary DNS is unavailable ...

Page 35: ...ls or deal another incoming call The Status section is for information only Settings SIP Proxy account set the user account parameters on the SIP Proxy Server registration protocols and registration expiry Caller ID set your own phone number or another unique ID consisting of characters and digits which together with the domain identifies in 2N SIP Mic calls and registration specify whether the UD...

Page 36: ...r is not applied set the registration expiry to control the registration Registration expiry request load of your network and SIP Registrar The SIP Registrar can modify the expiry without letting you know set the timeout for the to Timeout after wrong SIP registration 2N SIP Mic register after an unsuccessful registration attempt STUN server helps NAT clients i e the PCs behind the firewall set up...

Page 37: ...ia SIP INFO messages according to RFC SIP info 2976 set the payload type for DTMF any value from 96 to 127 DTMF payload type Make sure that the Proxy and end terminals are identical to make the function work properly set the local RTP port to be the source of the RTP stream sent from RTP port the device enable disable the use of audio codecs offered at the call setup Codec priority and set the pri...

Page 38: ...ejected with cause 404 Not Found set the incoming call answer Answer incoming call automatically 2N SIP Mic type does not answer incoming calls automatically Receive No 2N SIP Mic the call manually answer incoming calls immediately automatically Yes 2N SIP Mic receives incoming calls in x seconds For x seconds 2N SIP Mic automatically Set a value in the range of 1 3600 The maximum ringing time is ...

Page 39: ...call is signalled by flashing LEDs but does not affect the currently made call Ringing LED speaker tone the other incoming call is signalled by flashing LEDs and ringing tone from the speaker The ringing tone of the other call is different from the common ringing tone Note 2N SIP M ic is capable of serving up to two calls at the same time The third and next incoming calls are rejected Status SIP s...

Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 76 display the set IP address for NAT if used 0 0 0 0 is displayed when NAT IP STUN server or Local IP is used ...

Page 41: ...anically using a rotary potentiometer on the panel back Microphone sensitivity is controlled in the same way The amplifier is the same for the primary microphone attached to the device upper panel and an external microphone MIC IN Plug the connector into the socket to switch the signal direction This means that the two microphones are never active at the same time The attached external microphone ...

Page 42: ...age is played after the setup when the button is pressed an HHTP request is sent from HTTP request 2N SIP Mic when the button is pressed a call is set up to the set destination DTMF request via SIP Proxy The selected DTMF code is played after the setup the button controls the relay whose terminals are located on the Relay control back 2N SIP Mic the button activates the defined announcement to a z...

Page 43: ...nation phone number or IP URI to which the call shall be directed via SIP Proxy enter the DTMF code to be sent from after call connection DTMF 2N SIP Mic Not completed by default select a voice message to be played at call Select voice announcement connection No voice message is selected by default select automatic retry after call rejection Automatic retry after call rejection The selection is in...

Page 44: ...sed set the count of HTTP request sending retries if unsuccessful Retry count 0 to 30 The default value is 0 set the timeout in seconds for HTTP request sending Retry timeout retries 0 to 30 The default value is 10 s DTMF Request Destination s et the destination phone number or IP URI to which the call shall be directed via SIP Proxy ...

Page 45: ...ang up Relay Control Press a button to control the relay in one of the following three modes 2N SIP Mic Monostable the relay is activated for a defined period of time Relay activity time the relay state changes for a period of time defined by the parameter Bistable Minimum activation time the relay is active while the button is being Activate relay by pressing a button pressed yet for the minimum ...

Page 46: ... announcement end Automatically after timeout expiry after a timeout expiry Set values 0 to 9600 The default value is 10 make the announcement end when a button is By pressing a button pressed enable playing announcements after voice Announcement after voice message messages Load a message of your own in the System messages Voice messages menu Disabled by default the relay is activated when the ca...

Page 47: ...2N TELEKOMUNIKACE a s www 2n cz 47 76 ...

Page 48: ...nt for the Multicast address announcing device set the address for VAPIX communication VAPIX destination SIP Destination Call via SIP Proxy use the SIP Proxy set in the VoIP menu for outgoing calls route the call directly without the use of a SIP Proxy The Direct call required destination format is identification ip_address port enter the phone number for SIP Proxy or SIP URI for direct calls Dest...

Page 49: ...re sent The allowed range is 239 0 0 0 239 255 255 255 set the destination port to which the audio stream is sent Port set the maximum call duration after which the call shall Maximum call duration be terminated 0 to 60 min The default value is 0 min the parameter is not applied the call duration is unlimited set the audio codec for outgoing RTP packet encoding G 711a Audio codec alaw or G 711u ul...

Page 50: ...e destination port via which the device listens Port set the user name for authentication User name set the password for authentication Password set the maximum call duration after which the call shall Maximum call duration be terminated 0 to 60 min The default value is 0 min the parameter is not applied the call duration is unlimited set the audio codec for outgoing RTP packet encoding G 711a Aud...

Page 51: ...ons that require a microphone Each zone is assigned a name and short description Click the pencil symbol to open a zone setting dialogue Click the trash bin to delete the zone setting and deactivate the zone Note Some actions cannot be set using the Action scheduler 2N SIP Mic Outgoing call cannot be set due to the use of a microphone and speaker can be set to a limited extent due to the use of a ...

Page 52: ...e set the date on which the action becomes inactive End date set the weekdays and holidays on which the action is active Allowed days set the time at which the action is generated for the first time Use from set the time at which the action is not generated any longer Use to set the action repeating interval 5 to 120 minutes The default Retry interval value is 60 minutes make sure that any action ...

Page 53: ...ame for web login 2N SIP Mic Default user Admin set the password for web login Password 2N SIP Mic Default password 2n We strongly recommend you to change the password upon your first login set the automatic web interface logout time 10 Automatic logout 2N SIP Mic 3600 s The default value is 600 s ...

Page 54: ...e Winter Time zone 2N SIP Mic summer time is not considered automatically set a date in the DD MM RRRR format Date set a time value in the HH MM 24 hour format Time use the button to synchronise the time with your Set local time 2N SIP Mic current PC time value Press Apply to set the time value in whole minutes this function has not been implemented yet Syslog lock the console to prevent the actio...

Page 55: ...guration display a dialogue window for you to choose the configuration file to be uploaded back up the current configuration Press Download configuration 2N SIP Mic the button to download the full configuration to be saved on your PC upgrade your firmware Press the button to System upgrade 2N SIP Mic display a dialogue window for you to choose the firmware file for your 2N SIP is automatically res...

Page 56: ...the name is always Message x where x denotes the message number open a dialogue window to select the path to the audio file on your Load file PC hard drive Click the cross to delete a message without changing the message number press Play to play a message Click Stop which does not appear Play Stop until the playing starts to stop playing the current file Sound is played to your PC system speakers...

Page 57: ...nt after voice message open a dialogue window to select the path to the audio file on your Load file PC hard drive press Play to play a message Click Stop which does not appear Play Stop until the playing starts to stop playing the current file Sound is played to your PC system speakers or attached headset delete a user loaded file The name does not change and the original Delete system tone is re...

Page 58: ...vide examples of the settings The simplest 2N SIP Mic examples are always chosen so some functions can be neglected for simplification Refer to the Configuration subsections for full details 3 2 1 Express Settings 3 2 2 Announce to Zone VAPIX 3 2 3 Voice Message Loading 3 2 4 HTTP Request ...

Page 59: ...basic 2N SIP Mic parameters Step 1 Connection Pack out and connect the microphone and supply adapter included in the 2N SIP Mic delivery Insert a power cable connected to your LAN into the LAN connector on the back How to find the IP address 2N SIP Mic Turn on the device switch Wait until you can hear the sound signal Press the call hang up button on the device five times reads its IP address 2N S...

Page 60: ...ate it and click the pencil symbol The following dialogue window opens up Enter a button name into the Name field The description will be displayed in the menu Go to Action and select Announce to zone The menu will change according to the action selected Select a zone in Action settings Always choose the first zone even it lacks description Enable Announcement before after voice message if necessa...

Page 61: ...ings are completed Step 4 Playing Once the receivers are configured you can test the announcing function Press button 1 on the console The button should be shining blue and the call hang up button should be shining red Now the announcement before voice message is being played to the zone When the call pick up button starts shining blue you can send your own announcement to the zone via an attached...

Page 62: ...pted only in the HTTP RTSP Password Settings Allow password type in the VAPIX settings in the AXIS product Further settings relate to only You can use the steps included in the 2N SIP Mic preceding subsection Just change Multicast zone to VAPIX zone Having set the parameters adjust steps 2 and 3 If you have not tried express settings follow steps 1 and 2 Just select VAPIX as the zone in Action set...

Page 63: ...e sure that the AXIS user has operator rights at least Now SIP Mic define the Maximum call duration and Audio codec to be used for transmission G 711u uLAW is the only supported codec for VAPIX at present Click Change to save the settings Now you can play announcements to the VAPIX zone as well as to the multicast zone Refer to step 4 in the preceding subsection HTTPS Settings A security certifica...

Page 64: ...2N TELEKOMUNIKACE a s www 2n cz 64 76 Once you save the changes you can select HTTPS as the transport protocol in the 2N settings Refer to step 4 in the preceding subsection SIP Mic ...

Page 65: ...e and aLAW codec Or you can load a record from another file as the device automatically resamples it to the required format The m aximum size of the file to be loaded is 8 MB Note The audio record quality gets deteriorated during format resampling and so load your files with this limitation in mind Info Standard audio formats are supported WAV MP3 etc 8 kHz sampling frequency 8 bit resolution Maxi...

Page 66: ...tarts the original audio message is deleted irreversibly The maximum length of the audio message to be loaded is 60 s A microphone attached to the front panel is used as the default sound source If unattached connect a microphone to the back panel or LINE IN ...

Page 67: ...utton and press the button to send the command to for door lock relay activation 2N Helios IP Verso To set the HTTP command go to the configuration and open the button 2N SIP Mic menu Select one of the buttons activate it with a switch and click edit to open the following dialogue window Add a name to the action Select the HTTP request from the action list Set the action using the supported HTTP r...

Page 68: ...2N TELEKOMUNIKACE a s www 2n cz 68 76 Software 2N Helios IP network scanner 3 0 4 ...

Page 69: ...Harmonic distortion 0 05 1 kHz Signal to noise ratio 91 dB Headphones output stereo jack 3 5 mm 2x 30 mW min 16 Ohm DR 101 dB THD N 85 dB Digital input 2x 5 to 48 V DC digital input galvanically isolated or 1 contact input Main microphone input symetric XLR Phantom Supply 24 V DR 88 dB THD N 82 dB Headset microphone input jack 3 5 mm integrated powering for electret microphones DR 84 dB THD N 78 d...

Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 76 5 Supplementary Information Here is what you can find in this section 5 1 Troubleshooting 5 2 Directives Laws and Regulations 5 3 General Instructions and Cautions ...

Page 71: ...2N TELEKOMUNIKACE a s www 2n cz 71 76 5 1 Troubleshooting For the most frequently asked questions refer to faq 2n cz ...

Page 72: ...pment Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Regulation EC No 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction of Chemicals REACH establishing a European Chemic...

Page 73: ...eption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an ex...

Page 74: ...on of the product caused by incompetent replacement of parts or due to the use of reproduction parts or components The manufacturer shall not be liable and responsible for any loss or damage incurred as a result of a natural disaster or any other unfavourable natural condition The manufacturer shall not be held liable for any damage of the product arising during the shipping thereof The manufactur...

Page 75: ...ic Waste and Used Battery Pack Handling Do not place used electric devices and battery packs into municipal waste containers An undue disposal thereof might impair the environment Deliver your expired electric appliances and battery packs removed from them to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufact...

Page 76: ...2N TELEKOMUNIKACE a s www 2n cz 76 76 2N TELEKOMUNIKACE a s Modřanská 621 143 01 Prague 4 Czech Republic Phone 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz v1 0 ...

Reviews: