Chapter 84 ARP Inspection
XS3800-28 User’s Guide
631
Figure 498
SECURITY > IPv6 Source Guard > IPv6 Static Binding > IPv6 Static Binding > Add/Edit (Stacking
Mode)
The following table describes the labels in this screen.
84.10 IPv6 Source Guard Policy
Use this screen to have IPv6 source guard forward valid IPv6 addresses and/or IPv6 prefixes that are
stored in the binding table and allow or block data traffic from all link-local addresses. To open this
screen, click
SECURITY
>
IPv6 Source Guard
>
IPv6 Source Guard
>
IPv6 Source Guard Policy
.
• If you select
Validate Address
and not
Validate Prefix
, traffic for a binding entry that matches a IPv6
address and VLAN ID, port number, and MAC address will be forwarded. If this binding entry is a IPv6
prefix, the traffic will be denied.
• If you select
Validate Prefix
and not
Validate Address
, traffic for a binding entry that matches a IPv6
prefix and VLAN ID, port number, and MAC address will be forwarded. If this binding entry is a IPv6
address, the traffic will be denied.
Table 340 SECURITY > IPv6 Source Guard > IPv6 Static Binding > IPv6 Static Binding > Add/Edit
LABEL
DESCRIPTION
Source Address
Enter the
IPv6 Address
or
IPv6 Prefix
and prefix length in the binding.
MAC Address
Enter the source MAC address in the binding. If this binding does not check this field, select
Any
.
Note: You cannot choose
Any
for all three of
MAC Address
,
VLAN
and
Port
. You
must fill in at least one.
VLAN
Enter the source VLAN ID in the binding. If this binding does not check this field, select
Any
.
Port
Specify the ports in the binding. If this binding has one port, select the first radio button and
enter the port number in the field to the right. In Stacking mode, the first field is the slot ID and
the second field is the port number. If this binding applies to all ports, select
Any
.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Clear
Click
Clear
to clear the fields to the factory defaults.
Cancel
Click
Cancel
to not save the configuration you make and return to the last screen.
Summary of Contents for XS3800-28
Page 29: ...29 PART I User s Guide...
Page 54: ...54 PART II Technical Reference...
Page 88: ...Chapter 4 Web Configurator XS3800 28 User s Guide 88 Figure 51 Online Web Help...
Page 148: ...Chapter 20 Cloud Management XS3800 28 User s Guide 148 Figure 94 SYSTEM Cloud Management...
Page 263: ...Chapter 36 OAM XS3800 28 User s Guide 263 Figure 182 PORT OAM OAM Status OAM Details...
Page 540: ...Chapter 72 VRRP XS3800 28 User s Guide 540 Figure 434 VRRP Example 2 VRRP Status on Switch B...
Page 581: ...Chapter 77 Policy Rule XS3800 28 User s Guide 581 Figure 456 Policy Example...