Chapter 60 VLAN Stacking
XS3800-28 User’s Guide
451
Type
is a standard Ethernet type code identifying the frame and indicates that whether the frame
carries IEEE 802.1Q tag information.
SP TPID
(Service Provider Tag Protocol Identifier) is the service
provider VLAN stacking tag type.
Many vendors use 0x8100 or 0x9100.
TPID
(Tag Protocol Identifier) is the customer IEEE 802.1Q tag.
• If the VLAN stacking port role is
Access
port, then the Switch adds the
SP TPID
tag to all incoming
frames on the service provider's edge devices (1 and 2 in the VLAN stacking example figure).
• If the VLAN stacking port role is
Tunnel
port, then the Switch only adds the
SP TPID
tag to all incoming
frames on the service provider's edge devices (1 and 2 in the VLAN stacking example figure) that
have an
SP TPID
different to the one configured on the Switch. (If an incoming frame’s
SP TPID
is the
same as the one configured on the Switch, then the Switch will not add the tag.)
Priority
refers to the IEEE 802.1p standard that allows the service provider to prioritize traffic based on the
class of service (CoS) the customer has paid for.
• On the Switch, configure priority level of the inner IEEE 802.1Q tag in the
PORT
>
Port Setup
screen.
• "0" is the lowest priority level and "7" is the highest.
VID
is the VLAN ID.
SPVID
is the VID for the second (service provider’s) VLAN tag.
60.3.1 Frame Format
The frame format for an untagged Ethernet frame, a single-tagged 802.1Q frame (customer) and a
“double-tagged” 802.1Q frame (service provider) is shown next.
Configure the fields as highlighted in the Switch
SWITCHING
>
VLAN Stacking
screens.
60.4 Configuring VLAN Stacking
Click
SWITCHING
>
VLAN Stacking
to display the screen as shown.
Table 223 Single and Double Tagged 802.1Q Frame Format
DA
SA
Len/Etype
Data
FCS
Untagged
Ethernet frame
DA
SA
TPID
Priority
VID
Len/Etype
Data
FCS
IEEE 802.1Q
customer
tagged frame
DA
SA
SPTPID
Priority
VID
TPID
Priority VID
Len/Etype
Data
FCS
Double-tagged
frame
Table 224 802.1Q Frame
DA
Destination Address
Priority
802.1p Priority
SA
Source Address
Len/Etype
Length and type of Ethernet frame
(SP)TPID
(Service Provider) Tag Protocol IDentifier
Data
Frame data
VID
VLAN ID
FCS
Frame Check Sequence
Summary of Contents for XS3800-28
Page 29: ...29 PART I User s Guide...
Page 54: ...54 PART II Technical Reference...
Page 88: ...Chapter 4 Web Configurator XS3800 28 User s Guide 88 Figure 51 Online Web Help...
Page 148: ...Chapter 20 Cloud Management XS3800 28 User s Guide 148 Figure 94 SYSTEM Cloud Management...
Page 263: ...Chapter 36 OAM XS3800 28 User s Guide 263 Figure 182 PORT OAM OAM Status OAM Details...
Page 540: ...Chapter 72 VRRP XS3800 28 User s Guide 540 Figure 434 VRRP Example 2 VRRP Status on Switch B...
Page 581: ...Chapter 77 Policy Rule XS3800 28 User s Guide 581 Figure 456 Policy Example...