Chapter 9 VLAN
XGS-4526/4528F/4728F User’s Guide
125
The following table describes the labels in this screen.
Table 19
Advanced Application > VLAN > VLAN Port Setting
LABEL
DESCRIPTION
GVRP
GVRP (GARP VLAN Registration Protocol) is a registration protocol that
defines a way for switches to register necessary VLAN members on
ports across the network.
Select this check box to permit VLAN groups beyond the local Switch.
Port
This field displays the port number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all
ports. Use this row first to set the common settings and then make
adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you
make them.
Ingress Check
If this check box is selected for a port, the Switch discards incoming
frames for VLANs that do not include this port in its member set.
Clear this check box to disable ingress filtering.
PVID
A PVID (Port VLAN ID) is a tag that adds to incoming untagged frames
received on a port so that the frames are forwarded to the VLAN group
that the tag defines.
Enter a number between 1and 4094 as the port VLAN ID.
GVRP
Select this check box to allow GVRP on this port.
Acceptable
Frame Type
Specify the type of frames allowed on a port. Choices are All, Tag Only
and Untag Only.
Select All from the drop-down list box to accept all untagged or tagged
frames on this port. This is the default setting.
Select Tag Only to accept only tagged frames on this port. All untagged
frames will be dropped.
Select Untag Only to accept only untagged frames on this port. All
tagged frames will be dropped.
VLAN Trunking
Enable VLAN Trunking on ports connected to other switches or routers
(but not ports directly connected to end users) to allow frames
belonging to unknown VLAN groups to pass through the Switch.
Isolation
Select this to allows this port to communicate only with the CPU
management port and the ports on which the isolation feature is not
enabled.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The
Switch loses these changes if it is turned off or loses power, so use the
Save link on the top navigation panel to save your changes to the non-
volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Summary of Contents for XGS-4528F
Page 2: ......
Page 8: ...Safety Warnings XGS 4526 4528F 4728F User s Guide 8...
Page 24: ...Table of Contents XGS 4526 4528F 4728F User s Guide 24...
Page 25: ...25 PART I User s Guide...
Page 26: ...26...
Page 32: ...Chapter 1 Getting to Know Your Switch XGS 4526 4528F 4728F User s Guide 32...
Page 36: ...Chapter 2 Hardware Installation and Connection XGS 4526 4528F 4728F User s Guide 36...
Page 93: ...93 PART II Technical Reference...
Page 94: ...94...
Page 100: ...Chapter 7 System Status and Port Statistics XGS 4526 4528F 4728F User s Guide 100...
Page 116: ...Chapter 8 Basic Setting XGS 4526 4528F 4728F User s Guide 116...
Page 136: ...Chapter 9 VLAN XGS 4526 4528F 4728F User s Guide 136...
Page 140: ...Chapter 10 Static MAC Forward Setup XGS 4526 4528F 4728F User s Guide 140...
Page 172: ...Chapter 14 Bandwidth Control XGS 4526 4528F 4728F User s Guide 172...
Page 186: ...Chapter 17 Link Aggregation XGS 4526 4528F 4728F User s Guide 186...
Page 196: ...Chapter 18 Port Authentication XGS 4526 4528F 4728F User s Guide 196...
Page 214: ...Chapter 21 Policy Rule XGS 4526 4528F 4728F User s Guide 214...
Page 258: ...Chapter 25 AAA XGS 4526 4528F 4728F User s Guide 258...
Page 282: ...Chapter 26 IP Source Guard XGS 4526 4528F 4728F User s Guide 282...
Page 314: ...Chapter 32 Error Disable XGS 4526 4528F 4728F User s Guide 314...
Page 318: ...Chapter 33 Private VLAN XGS 4526 4528F 4728F User s Guide 318...
Page 322: ...Chapter 34 Static Route XGS 4526 4528F 4728F User s Guide 322...
Page 330: ...Chapter 36 RIP XGS 4526 4528F 4728F User s Guide 330...
Page 386: ...Chapter 43 ARP Learning XGS 4526 4528F 4728F User s Guide 386...
Page 396: ...Chapter 45 Maintenance XGS 4526 4528F 4728F User s Guide 396...
Page 442: ...Chapter 49 Cluster Management XGS 4526 4528F 4728F User s Guide 442...
Page 446: ...Chapter 50 MAC Table XGS 4526 4528F 4728F User s Guide 446...
Page 450: ...Chapter 51 IP Table XGS 4526 4528F 4728F User s Guide 450...
Page 454: ...Chapter 53 Routing Table XGS 4526 4528F 4728F User s Guide 454...
Page 462: ...Chapter 55 Troubleshooting XGS 4526 4528F 4728F User s Guide 462...
Page 472: ...Chapter 56 Product Specifications XGS 4526 4528F 4728F User s Guide 472...
Page 480: ...Appendix B Legal Information XGS 4526 4528F 4728F User s Guide 480...