VES-1616F/1624F-44 User’s Guide
154
Chapter 21 VLAN Stacking
21.4 Configuring VLAN Stacking
Click
Advanced Applications
and then
VLAN Stacking
in the navigation panel to display
the screen as shown.
Figure 75
VLAN Stacking
The following table describes the labels in this screen.
Table 61
VLAN Stacking
LABEL
DESCRIPTION
Active
Select this checkbox to enable VLAN stacking on the switch.
SP TPID
SP TPID
is a standard Ethernet type code identifying the frame and indicates whether the
frame carries IEEE 802.1Q tag information. Choose
0x8100
or
0x9100
from the drop-down
list box or select
Others
and
then enter a four-digit hexadecimal number from 0x0000 to
0xFFFF. 0x denotes a hexadecimal number. It does not have to be typed in the
Others
text
field.
Port
The port number identifies the port you are configuring.
Role
Select
Normal
to have the switch ignore frames received (or transmitted) on this port with
VLAN stacking tags. Anything you configure in
SPVID
and
Priority
are ignored.
Select
Access Port
to have the switch add the
SP TPID
tag to all incoming frames received
on this port. Select
Access Port
for ingress ports at the edge of the service provider's
network.
Select
Tunnel
(available for Gigabit ports only) for egress ports at the edge of the service
provider's network.
In order to support VLAN stacking on a port, the port must be able to allow frames of 1526
Bytes (1522 Bytes + 4 Bytes for the second tag) to pass through it.
SPVID
SPVID
is the service provider’s VLAN ID (the outer VLAN tag). Enter the service provider ID
(from 1 to 4094) for frames received on this port. See
for more
background information on VLAN ID.
Summary of Contents for VES-1616F-44
Page 1: ...VES 1616F 1624F 44 VDSL Switch User s Guide Version 3 50 2 2007 Edition 2...
Page 9: ...VES 1616F 1624F 44 User s Guide 8 Customer Support...
Page 23: ...VES 1616F 1624F 44 User s Guide 22 List of Figures...
Page 27: ...VES 1616F 1624F 44 User s Guide 26 List of Tables...
Page 53: ...VES 1616F 1624F 44 User s Guide 52 Chapter 4 The Web Configurator...
Page 63: ...VES 1616F 1624F 44 User s Guide 62 Chapter 5 System Status and Port Statistics...
Page 93: ...VES 1616F 1624F 44 User s Guide 92 Chapter 7 VLAN...
Page 103: ...VES 1616F 1624F 44 User s Guide 102 Chapter 10 Spanning Tree Protocol...
Page 117: ...VES 1616F 1624F 44 User s Guide 116 Chapter 15 Port Authentication...
Page 139: ...VES 1616F 1624F 44 User s Guide 138 Chapter 18 Queuing Method...
Page 145: ...VES 1616F 1624F 44 User s Guide 144 Chapter 19 Classifier...
Page 150: ...VES 1616F 1624F 44 User s Guide Chapter 20 Policy 149 Figure 73 Policy Example...
Page 151: ...VES 1616F 1624F 44 User s Guide 150 Chapter 20 Policy...
Page 157: ...VES 1616F 1624F 44 User s Guide 156 Chapter 21 VLAN Stacking...
Page 165: ...VES 1616F 1624F 44 User s Guide 164 Chapter 22 Multicast...
Page 173: ...VES 1616F 1624F 44 User s Guide 172 Chapter 23 Multicast VLAN Registration...
Page 177: ...VES 1616F 1624F 44 User s Guide 176 Chapter 24 DHCP...
Page 181: ...VES 1616F 1624F 44 User s Guide 180 Chapter 25 Differentiated Services...
Page 182: ...VES 1616F 1624F 44 User s Guide Chapter 25 Differentiated Services 181...
Page 183: ...VES 1616F 1624F 44 User s Guide 182 Chapter 25 Differentiated Services...
Page 193: ...VES 1616F 1624F 44 User s Guide 192 Chapter 27 Maintenance...
Page 195: ...VES 1616F 1624F 44 User s Guide 194 Chapter 28 Diagnostic...
Page 199: ...VES 1616F 1624F 44 User s Guide 198 Chapter 29 Syslog...
Page 259: ...VES 1616F 1624F 44 User s Guide 258 Chapter 33 Command Examples...
Page 267: ...VES 1616F 1624F 44 User s Guide 266 Chapter 34 IEEE 802 1Q Tagged VLAN Commands...
Page 277: ...VES 1616F 1624F 44 User s Guide 276 Chapter 35 Troubleshooting...
Page 281: ...VES 1616F 1624F 44 User s Guide 280 Product Specifications...