PoE-80 

Eight-port Power over Ethernet Hub 

 

 

 

User’s Guide 

 

Version 1.06 

April 2004 

 

 

 

Summary of Contents for PoE-80

Page 1: ...PoE 80 Eight port Power over Ethernet Hub User s Guide Version 1 06 April 2004...

Page 2: ...ware and Installation 10 2 1 Desktop Installation 10 2 2 Rack mounted Installation 10 2 3 Rear Panel Connections 11 2 4 Front Panel Connections 12 2 5 Front Panel LEDs 12 3 Software Utility Installati...

Page 3: ...described herein without notice This publication is subject to change without notice Trademarks Trademarks mentioned in this publication are used for identification purposes only and may be properties...

Page 4: ...he drop down list box on the ZyXEL home page to go to that product s page 3 Select the certification you wish to view from this page Information for Canadian Users The Industry Canada label identifies...

Page 5: ...place the defective products or components without charge for either parts or labor and to whatever extent it shall deem necessary to restore the product or components to proper operating condition An...

Page 6: ...over Ethernet Hub may be called the PoE 80 the power injector or the system in this guide Customer Support When you contact your customer support representative please have the following information...

Page 7: ...FRANCE info zyxel fr 33 0 4 72 52 19 20 www zyxel fr ZyXEL France 1 rue des Vergers Bat 1 C 69760 Limonest France support zyxel es 34 902 195 420 SPAIN sales zyxel es 34 913 005 345 www zyxel es ZyXE...

Page 8: ......

Page 9: ...e 1 1 Key Features Eight RJ 45 10 100 Mbps PoE enabled ports Ensures a constant power supply to PoE enabled devices Automatically detects if connected devices are PoE enabled to avoid sending power to...

Page 10: ...e supplied rubber feet Step 4 Attach the rubber feet to each corner on the bottom of the PoE 80 These rubber feet help protect the PoE 80 from shock or vibration and ensure space between devices when...

Page 11: ...in the brackets with the appropriate holes on the rack Secure the PoE 80 to the rack with the rack s mounting screws 2 3 Rear Panel Connections Connect the female end of the power cord to the power r...

Page 12: ...The DATA OUT port is connected and sending power to an Ethernet device The DATA OUT port is not sending power to an Ethernet device PWR OFF Orange On Off The Ethernet device connected to the PoE 80 s...

Page 13: ...your CD ROM drive Step 2 Run browse to and double click setup exe Step 3 The installation screen displays Click OK to go to the next step Step 4 Click the icon button to start the installation Step 5...

Page 14: ...PoE 80 User s Guide 14 Step 6 Click Yes if the Version Conflict screen displays Step 7 When installation finishes click OK to finish...

Page 15: ...rt Programs ZyXEL Power over Ethernet Series and then ZyXEL Power over Ethernet Series to run the software utility 4 Removing the Utility Use the following procedure to remove the software utility fro...

Page 16: ...PoE 80 User s Guide 16 Step 2 Click Add or Remove Programs Step 3 Click ZyXEL Power over Ethernet Series and Change Remove Step 4 Click Yes to remove the software utility Step 5 Click OK...

Page 17: ...abled device to a DATA OUT port on the PoE 80 Start the utility and the management interface displays as shown next The configuration changes you make in the utility are not saved when you turn off th...

Page 18: ...ault settings The device resets and the PWR FWD and PWR OFF LEDs flash You must disconnect all of the PoE enabled devices from the PoE 80 before you calibrate the system PD Discovery R ohms Set the up...

Page 19: ...this button to apply the new configuration to the PoE 80 Configuration changes are lost when you turn off the PoE 80 or it loses power 5 3 Port Specific Control This section of the screen displays por...

Page 20: ...connected to the port Fault Status This displays the status Null Overload or DR Fail of the connected PoE enabled device that the system has detected Null No PoE enabled device is connected to the po...

Page 21: ...alue does not display when you enable the bypass classification function 6 Troubleshooting Make sure you have securely attached the proper cables to the proper ports Refer to the Rear Panel Connection...

Page 22: ...maximum Current per port maximum 350mA 48V DC Management Microsoft Windows based application for power management Power Management Functions Current ports serviced list system total serviced power bu...

Page 23: ...uide 23 7 1 DATA OUT PoE Injector RJ 45 Port Pin Assignments PIN NO RJ 45 SIGNAL ASSIGNMENT 1 Output Transmit Data 2 Output Transmit Data 3 Receive Data 4 Power 5 Power 6 Receive Data 7 Power 1 2 3 4...