Chapter 5 The Configuration Utility
PLA-402 v3 User’s Guide
38
5.4 Firmware Screen
Use the
Firmware
screen to update the firmware on the PLA-402 v3 directly
connected to the computer running the configuration utility.
Site
This field displays
•
Local
, if it is identifying the coaxial adapter directly connected to the
computer running the configuration utility.
•
Remote
, if it is a coaxial adapter in your powerline coaxial network but
not directly connected to the computer running the configuration utility.
MAC Address This is a read-only field which shows the MAC address of the coaxial
adapter you are configuring. You can find the MAC address of your PLA-
402 v3 displayed on a sticker on the bottom of your device.
DAK
Password
DAK (Device Access Key) password is used to verify that you are
authorized to perform changes on a remote device. You can find the DAK
password printed on a sticker on the bottom of your PLA-402 v3.
Select the remote coaxial adapter you want to manage by clicking the MAC
address which corresponds to it in the
MAC Address
column. Enter the
DAK Password
value and click
Save
.
Note: You must enter the DAK Password value exactly as it is printed
on the label (all caps and with dashes “-”).
Network
Name
The default network name (sometimes called a network password or
network membership key (NMK)) of the PLA-402 v3 is “
HomePlugAV
”.
HomePlug compatible devices use the same network name to recognize
and communicate with each other over the powerline coaxial network. If
you change the network name of one device on the network, it will no
longer be recognized as part of that network.
If you change the network name, make sure you change the network
name for all of the coaxial adapters that you want to be part of your
powerline coaxial network.
The network name can be from 8 to 64 characters in length, using
“A”~”Z”, “a”~”z”, “0”~”9”; spaces are not allowed.
Set NMK to
this device
Select this to apply the NMK (entered in the field above) as the network
name for the coaxial adapter directly connected to the computer running
the configuration utility.
Set NMK to
all devices
Select this to apply the NMK (entered in the field above) as the network
name for all coaxial adapter detected by the utility.
Save
Click this to apply your changes. The new
Network Name
is applied to
the selected coaxial adapter.
Note: You must enter the correct DAK password for the selected
coaxial adapter before you can make changes to it.
Table 3
Configuration Screen (continued)
LABEL
DESCRIPTION
Summary of Contents for PLA-402 v3
Page 2: ......
Page 12: ...Table of Contents PLA 402 v3 User s Guide 12...
Page 13: ...13 PART I Introduction Introducing the PLA 402 v3 15 Installing the Utility 21...
Page 14: ...14...
Page 20: ...Chapter 1 Introducing the PLA 402 v3 PLA 402 v3 User s Guide 20...
Page 26: ...26...
Page 28: ...Chapter 3 Firmware Tool PLA 402 v3 User s Guide 28...
Page 46: ...Chapter 5 The Configuration Utility PLA 402 v3 User s Guide 46...
Page 60: ...Chapter 6 The OS X Configuration Utility PLA 402 v3 User s Guide 60...
Page 70: ...Chapter 7 Powerline Coaxial Network Setup Tutorial PLA 402 v3 User s Guide 70...
Page 74: ...Chapter 8 PLA Compatibility PLA 402 v3 s User s Guide 74...
Page 76: ...76...
Page 84: ...Chapter 9 LEDs and Troubleshooting PLA 402 v3 User s Guide 84...
Page 92: ...Appendix A Legal Information PLA 402 v3 User s Guide 92...