NetAtlas Enterprise Ethernet Switch Manager User’s Guide
141
Chapter 16 Ethernet Port Configuration
The following table describes the fields in this screen.
Table 69
Ethernet Port Configuration: Port Setup
LABEL
DESCRIPTION
Timeout
(seconds)
The text box displays how long (in seconds) an SNMP request times out. You may
change the timeout by typing a new number in the text box and then clicking the
Apply
button.
Active
Select this check box to enable a port. The factory default for all ports is enabled. A port
must be enabled for data transmission to occur.
Type
This field displays the port type and port speed.
Port Name
This field displays the name of a selected port.
Speed/Duplex Select the speed and the duplex mode of the Ethernet connection on this port. Choices
are
Auto
,
10M/Half Duplex
,
10M/Full Duplex
,
100M/Half Duplex
,
100M/Full Duplex
and
1000M/Full Duplex
(for Gigabit/mini-GBIC ports only).
Selecting
Auto
(auto-negotiation) makes one Ethernet port able to negotiate with a
peer automatically to obtain the connection speed and duplex mode that both ends
support. When auto-negotiation is turned on, an Ethernet port on the switch negotiates
with the peer automatically to determine the connection speed and duplex mode. If the
peer Ethernet port does not support auto-negotiation or turns off this feature, the switch
determines the connection speed by detecting the signal on the cable and using half
duplex mode. When the switch’s auto-negotiation is turned off, an Ethernet port uses
the pre-configured speed and duplex mode when making a connection, thus requiring
you to make sure that the settings of the peer Ethernet port are the same in order to
connect.
Flow Control
A concentration of traffic on a port decreases port bandwidth and overflows buffer
memory causing packet discards and frame losses. Flow Control is used to regulate
transmission of signals to match the bandwidth of the receiving port. The switch uses
IEEE 802.3x flow control in full duplex mode and backpressure flow control in half
duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the
sending port, causing it to temporarily stop sending signals when the receiving port
memory buffers fill. Back Pressure flow control is typically used in half duplex mode to
send a "collision" signal to the sending port (mimicking a state of packet collision)
causing the sending port to temporarily stop sending signals and resend later. Select
Flow Control
to enable it.
802.1p Priority The switch uses this priority value for incoming frames without an IEEE 802.1p priority
queue tag. The switch uses this priority value internally and does not add an IEEE
802.1p priority tag.
Intrusion Lock Select the
Intrusion Lock
check box to enable this security feature on a selected port
on the switch. If an Ethernet cable is disconnected from the port, intrusion locking
prevents access once a cable is reconnected. This limits risk from unauthorized access
such as hacking.
Note:
You cannot access a port with intrusion locking enabled after a
cable is disconnected and then reconnected. You must clear and
re-select the
Intrusion Lock
check box to allow access to the
port again.
Jumbo Frame Jumbo frames are used to forward non-standard packet sizes on your network. These
frames can deliver frames of up to 9216 bytes instead of standard Ethernet frames of
1522 bytes. Fewer packets are required for large data transfer, improving traffic
throughput on the port.
Select this option to allow a port to send and receive jumbo frames.
Note:
The peer device must also support non-standard packet traffic.
Summary of Contents for NETATLAS ENTERPRISE -
Page 1: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide Version 1 02 1 2006 ...
Page 21: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 21 List of Tables ...
Page 27: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 27 Chapter 1 Introduction ...
Page 35: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 35 Chapter 2 Switch Manager ...
Page 45: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 45 Chapter 3 EMS Main Window ...
Page 67: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 67 Chapter 5 View ...
Page 91: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 91 Chapter 9 Fault ...
Page 99: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 99 Chapter 10 Maintenance ...
Page 103: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 103 Chapter 11 Tools ...
Page 109: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 109 Chapter 12 Device Menu Overview ...
Page 119: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 119 Chapter 13 System Configuration ...
Page 133: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 133 Chapter 14 Switch Configuration ...
Page 191: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 191 Appendix A SNMPc Network Manager ...
Page 193: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 193 Appendix B ...