Chapter 8 Basic Setting
MES3500 Series User’s Guide
78
8.2 General Setup
Use this screen to configure general settings such as the system name and time. Click
Basic
Setting
>
General Setup
in the navigation panel to display the screen as shown.
Figure 31
Basic Setting > General Setup
Temperature
BOARD
,
MAC
and
PHY
refer to the location of the temperature sensors on the Switch
printed circuit board.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Status
This field displays
Normal
for temperatures below the threshold and
Error
for those above.
Voltage(V)
The power supply for each voltage has a sensor that is capable of detecting and reporting if
the voltage falls out of the tolerance range.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Threshold
This field displays the percentage tolerance of the voltage with which the Switch still works.
Status
Normal
indicates that the voltage is within an acceptable operating range at this point;
otherwise
Error
is displayed.
Table 11
Basic Setting > System Info (continued)
LABEL
DESCRIPTION
Summary of Contents for MES3500 Series
Page 16: ...Table of Contents MES3500 Series User s Guide 16 Appendix C Legal Information 357 Index 362...
Page 17: ...17 PART I User s Guide...
Page 72: ...72 PART II Technical Reference...
Page 178: ...Chapter 22 Policy Rule MES3500 Series User s Guide 178 Figure 98 Policy Example EXAMPLE...
Page 360: ...Appendix C Legal Information MES3500 Series User s Guide 360 Environmental Product Declaration...