background image

www.zyxel.com

www.zyxel.com

IES-5106M / IES-5112M /    
IES-6000M

Integrated Ethernet Switch

Copyright © 2011
ZyXEL Communications Corporation

Version 1.00

Edition 2, 03/2011

Default Login Details

IP Address

http://192.168.1.1

User Name

admin

Password

1234

Summary of Contents for IES-6000M

Page 1: ...l com IES 5106M IES 5112M IES 6000M Integrated Ethernet Switch Copyright 2011 ZyXEL Communications Corporation Version 1 00 Edition 2 03 2011 Default Login Details IP Address http 192 168 1 1 User Nam...

Page 2: ......

Page 3: ...umentation Line Card User s Guides These User s Guides provide hardware connection details and explain how to configure and manage the individual line cards Management Switch Card User s Guide This Us...

Page 4: ...roducts Forum This contains discussions on ZyXEL products Learn from others who use ZyXEL products and share your experiences as well Customer Support Should problems arise that cannot be solved by th...

Page 5: ...ble with the IES It may be referred to as the IES 5000ST or the splitter chassis The IES 5002ST splitter chassis is compatible with the IES It may be referred to as the IES 5002ST or the splitter chas...

Page 6: ...the VOP1248G the VOP or the line card in this User s Guide IES refers to the main chassis and its cards along with the splitter chassis and its cards The IES 6000 may be referred to as the IES the sy...

Page 7: ...servicing or disassembling Use ONLY a power wire of the appropriate wire gauge see Chapter 5 on page 75 for details for your device Connect it to a power supply of the correct voltage see Chapter 5 on...

Page 8: ...rning Replace a fuse only with a fuse of the same type and rating The length of exposed bare power wire should not exceed 10 mm Warning This equipment must be grounded Never defeat the ground conducto...

Page 9: ...User s Guide 9 Contents Overview Introduction 19 System Introduction 21 Installation and Connections 25 Hardware Installation and Connections 27 Maintenance and Troubleshooting 57 Maintenance 59 Hard...

Page 10: ...Contents Overview IES 5106M IES 5112M IES 6000M User s Guide 10...

Page 11: ...5106M IES 5112M Frame Ground 23 2 2 4 Connecting the IES 6000M Frame Ground 25 2 3 Card Installation 26 2 3 1 Installing MSC and Line Cards 26 2 3 2 Removing MSC and Line Cards 29 2 3 3 Installing a S...

Page 12: ...the IES Power 62 Chapter 3 Hardware Troubleshooting 63 3 1 The PWR LED Does Not Turn On or Is Blinking 63 3 2 The ALM LED Is On 63 3 3 No Voice on an ADSL Connection 64 3 4 No Voice on a VoIP Connect...

Page 13: ...bscribers 360 when using the ALC1272 72 port line card can simultaneously utilize a wide range of powerful broadband services The IES 5112M can hold a maximum of ten line cards so up to 480 subscriber...

Page 14: ...ality videoconferencing 1 2 1 MTU Application The following diagram depicts a typical application of the IES in a large residential building or multiple tenant unit MTU This application leverages exis...

Page 15: ...IES 6000M User s Guide 15 1 2 2 Central Office Application The IES provides DSL and voice service over telephone wires to subscribers The following figure shows the IES setup in a telephone company s...

Page 16: ...Introduction IES 5106M IES 5112M IES 6000M User s Guide 16 1 3 Front Panel The following figures show the main chassis front panels with cards installed Figure 3 IES 5106M Front Panel Figure 4 IES 51...

Page 17: ...Chapter 1 System Introduction IES 5106M IES 5112M IES 6000M User s Guide 17 Figure 5 IES 6000M Front Panel...

Page 18: ...Chapter 1 System Introduction IES 5106M IES 5112M IES 6000M User s Guide 18...

Page 19: ...next section to install them Refer to Section 2 6 on page 47 for instructions on making connections with Telco 50 connectors Refer to Section 2 7 on page 57 for instructions on making alarm connectio...

Page 20: ...n a Rack Make sure that nothing obstructs the airflow of the main chassis If you are facing the IES 5106M or IES 5112M front panel the fan exhaust vents are located on the right side panel of the unit...

Page 21: ...72 port line cards use two IES 5000ST splitter chassis If you are using 48 port line cards use one IES 5000ST splitter chassis and one IES 5002ST splitter chassis Note For the IES 6000M if you are us...

Page 22: ...ES 5106M IES 5112M IES 6000M User s Guide 22 3 Repeat steps 1 2 to attach the second mounting bracket on the other side of the main chassis Figure 9 Attaching Mounting Brackets to the IES 5106M Figure...

Page 23: ...bracket holes into the rack 6 Repeat steps 4 5 to attach the second mounting bracket on the other side of the rack 2 2 3 Connecting the IES 5106M IES 5112M Frame Ground Refer to Chapter 5 on page 75...

Page 24: ...Installation and Connections IES 5106M IES 5112M IES 6000M User s Guide 24 Figure 12 IES 5106M IES 5112M Frame Ground Figure 13 IES 5005ST Splitter Chassis Frame Ground Figure 14 IES 5000ST Splitter C...

Page 25: ...for the ground wire gauge The IES 6000M frame ground is on the lower right corner of the front panel The IES 3000ST or IES 3016ST frame ground is near the lower left corner of the rear panel Connect...

Page 26: ...unused slots 2 3 1 Installing MSC and Line Cards Use the following procedure to install management switch cards and line cards in the main chassis 1 Grasp the center of the front panel of the card wi...

Page 27: ...other cards so you need to exert more force to get the MSC all the way in and properly seated in the backplane Make sure the front panel of the MSC is touching the front panel of the chassis The MSC...

Page 28: ...Chapter 2 Hardware Installation and Connections IES 5106M IES 5112M IES 6000M User s Guide 28 Figure 19 Closing the Ejector Levers Figure 20 Tightening Card Thumbscrews...

Page 29: ...two ejector levers firmly until the front of the card is clear of the main chassis Pull the ejector levers until they are perpendicular to the front panel Note The MSC has more connector pins than th...

Page 30: ...Chapter 2 Hardware Installation and Connections IES 5106M IES 5112M IES 6000M User s Guide 30 Figure 22 Opening the Ejector Levers Figure 23 Removing a Main Chassis Card...

Page 31: ...there is one splitter chassis below the main IES main chassis install a line card s splitter or extension cards below the line card and in adjacent slots a management switch card does not need a split...

Page 32: ...rd Use the following procedure to remove a splitter or extension card from the splitter chassis 1 Disconnect the cable from the card 2 Loosen the two thumbscrews 3 Grasp the handles on the front panel...

Page 33: ...connect the line cards to the splitter chassis cards For the management switch card refer to the card s User s Guide for instructions on making the connections 2 4 1 IES 5106M IES 5112M 48 port Line...

Page 34: ...ter card in the left column labeled x 1 of the splitter chassis Use a short Telco 50 cable to connect a line card s 25 48 Telco 50 connector to the Telco 50 connector on the corresponding splitter car...

Page 35: ...ure 29 IES 5112M Front Panel Telco 50 Connections with 10 Line Cards 2 4 2 IES 5106M IES 5112M 72 port Line Card Connections When using 72 port line cards such as the ALC1272G use two IES 5005ST for I...

Page 36: ...Chapter 2 Hardware Installation and Connections IES 5106M IES 5112M IES 6000M User s Guide 36 Figure 30 IES 5106M Front Panel Telco 50 Connections with 72 port Line Cards...

Page 37: ...lco 50 Connections with 72 port Line Cards The 72 port line cards use long medium and short Telco 50 cables see Chapter 5 on page 75 for the exact lengths of each cable Note These cables are different...

Page 38: ...5005 1 to 8 and the numbers in parentheses refer to the Telco 50 port connector on the line card ports 1 24 25 48 and 49 72 2 4 2 2 IES 5112M 72 port Line Card to Splitter Card Connections Connect the...

Page 39: ...tter IES 5112M 1 1 1 24 1 25 48 1 49 72 2 2 1 24 2 25 48 2 49 72 3 3 1 24 3 25 48 3 49 72 4 4 1 24 4 25 48 4 49 72 5 5 1 24 5 25 48 5 49 72 6 6 1 24 6 25 48 6 49 72 7 7 1 24 7 25 48 7 49 72 8 8 1 24 8...

Page 40: ...ignal from the DSL signal It feeds the DSL signals to the DSL line card and diverts the voice signal to the CO Telco 50 connector or wire wrapping pins on the splitter chassis rear Connect the CO Telc...

Page 41: ...one wiring via a Main Distribution Frame MDF 2 5 IES 6000M Card Connections The following describes how to connect the line cards to the splitter chassis cards For the management switch card refer to...

Page 42: ...48 Telco 50 connector to the Telco 50 connector on the corresponding splitter card of the upper splitter chassis Use a long Telco 50 cable to connect a line card s 1 24 Telco 50 connector to the Telco...

Page 43: ...oIP Line Card Telco 50 Connections When you use a VoIP line card in conjunction with an ADSL or VDSL card place the VoIP card and its extension cards in the chassis directly adjacent to the DSL card a...

Page 44: ...e 35 IES 6000 DSL and VoIP Front Panel Telco 50 Connections 2 Splitter Chassis Use a Telco 50 cable to connect the SEC1024 s USER Telco 50 connector on the rear of the splitter chassis to the CO Telco...

Page 45: ...the CO Telco 50 connectors to the PBX or PSTN ISDN switch when using the ADSL splitter card Connect the USER Telco 50 connectors to the subscribers telephone wiring In most multi tenant unit applicat...

Page 46: ...line card s 1 24 ports Connect the USER Telco 50 connector from the extension card attached to the VoIP line card s 25 48 ports to the CO Telco 50 connector of the splitter card attached to the DSL li...

Page 47: ...An MDF is usually installed between subscribers equipment and the telephone company CO in a basement or telephone room The MDF is the point of termination for the outside telephone company lines comi...

Page 48: ...ly to an MDF Alternatively attach RJ 11 connectors and connect directly to DSL modems or telephones Note The cable shown below uses a 90 degree Telco 50 connector where the cable extends from the side...

Page 49: ...enarios 2 6 4 1 MDF Installation Scenario A You want to install the IES in an environment where there are no previously installed MDFs There is no phone service and you want to install the IES for dat...

Page 50: ...the Telco 50 connector labeled USER 2 Connect the wiring on the other end of the Telco 50 cable to the upper ports of the MDF using a punch down tool 3 Connect the telephone wiring from each end user...

Page 51: ...scenario requires three MDFs Please refer to the following figure for the connection schema MDF 1 is the original MDF used for telephone connections only MDF 2 is used for telephone connections only...

Page 52: ...r labeled CO on the splitter chassis rear panel 5 Connect the wiring on the other side of the Telco 50 cable to the lower ports of MDF 2 using a punch down tool 6 Connect the upper ports of MDF 2 to t...

Page 53: ...ser and CO Connections This installation scenario requires four MDFs Please refer to the following figure for the DSL connection schema MDFs 1 and 2 are the two original MDFs MDFs 3 and 4 are two addi...

Page 54: ...rts of MDF 3 using a punch down tool 3 Connect the lower ports of MDF 3 to the upper ports of MDF 2 for those users that want DSL service Users who want telephone service only retain the original conn...

Page 55: ...any 2 6 5 VoIP Connection Scenarios These scenarios describe how to use the VOP1248G VoIP line card to provide voice service to your subscribers 2 6 5 1 VoIP Installation Scenario A In this installati...

Page 56: ...o the lower ports of the MDF 2 6 5 2 VoIP Installation Scenario B In this installation scenario you use a VoIP line card and an SEC1024 extension card in conjunction with a DSL line card its associate...

Page 57: ...EC1024 extension card 5 Connect the Telco 50 port on the front of the DSL splitter card to the 1 24 port on the front of the DSL line card 6 Connect the Telco 50 port on the front of the SEC extension...

Page 58: ...stalling the Alarm Module 2 7 2 Removing the Alarm Module Use the following procedure to remove the alarm module from the main chassis 1 Use a screwdriver to loosen the alarm module screws 2 Grasp the...

Page 59: ...ls or another alarm occurs To signal a minor alarm the MSC opens the circuit for pins 4 and 12 and closes the circuit for pins 5 and 12 To signal a major alarm the MSC opens the circuit for pins 13 an...

Page 60: ...onnect the Power When installing the IES power wires push the wires firmly into the terminals as deep as possible and make sure that no exposed bare wires can be seen or touched Use four wires to conn...

Page 61: ...112M IES 6000M User s Guide 61 Figure 50 Sliding Out the IES Power Module Figure 51 Connecting the Power Wires to the IES Power Module 2 9 Dressing the Power Wires and Alarm Cable Use a cable tie to d...

Page 62: ...ns IES 5106M IES 5112M IES 6000M User s Guide 62 Figure 52 Dressing the IES 6000M Power Wires and Alarm Cable 2 9 1 Procedure to Turn on the IES Power 1 Turn on the power supply 2 Move the power switc...

Page 63: ...fan has failed in the fan module Working fans emit a low buzz and blow air If the fans are not working properly refer to Section 4 1 on page 67 for instructions on changing a fuse or changing the fan...

Page 64: ...ne Letters in the figure shown next indicate the systematic tests to be done Suppose you re using installation scenario B as shown in the chapter on MDF connections The logic for other scenarios shoul...

Page 65: ...Wiring STEP TEST A Wiring problem between the CO and MDF 1 Connect a standard telephone to MDF 1 If there is no dial tone then a problem with the wire or wire connections between MDF 1 and the CO exis...

Page 66: ...card If using a different splitter card solves the problem replace the first splitter card If using a different splitter card does not solve the problem the splitter chassis may be faulty contact you...

Page 67: ...the fuse is not the problem Return any malfunctioning fan modules to the manufacturer Perform the following procedure to remove the fan module in order to clean the fan filter or change a fan fuse or...

Page 68: ...Chapter 4 Maintenance IES 5106M IES 5112M IES 6000M User s Guide 68 Figure 54 Loosening the IES 5106M IES 5112M Fan Module Thumbscrews Figure 55 Removing the IES 5106M IES 5112M Fan Module...

Page 69: ...Replace the entire fan module if the fuse is not the problem Return any malfunctioning fan modules to the manufacturer Perform the following procedure to remove the fan module in order to change a fan...

Page 70: ...ntenance IES 5106M IES 5112M IES 6000M User s Guide 70 Figure 57 Loosening the IES 6000M Fan Module Thumbscrews Figure 58 Removing the IES 6000M Fan Module Figure 59 IES 6000M Fan Module Location of F...

Page 71: ...erent than the filters on the side panels so make sure you order the correct filter s To clean or replace the filter on the front panel loosen the thumbscrews on the front of the filter and remove the...

Page 72: ...t breaker Before you replace a power module make sure the circuit breaker is not causing the problem 4 2 1 Procedure to Disconnect the Power The power modules are hot swappable and can be disconnected...

Page 73: ...oosen the thumbscrews on the front panel of the IES power supply module 3 Grab the handle and slide out the power supply module 4 Disconnect the power wires from the IES power module terminals 5 Repla...

Page 74: ...Guide 74 Figure 63 Connecting the Power Wires to the IES Power Module 4 2 3 Procedure to Reconnect the Power 1 Reconnect the power wires to the power supply terminals 2 Turn the power supply back on...

Page 75: ...pable Line Cards The IES uses hot swappable line cards Hot swappable Splitter Cards The splitter chassis use hot swappable splitter cards Management Switch Card The IES accommodates a management switc...

Page 76: ...6ST 434 1 mm W x 280 mm D x 219 4 mm H 5U Chassis weight including fan and power module weight excluding card weights IES 5106M 10 2 kg IES 5112M 13 34 kg IES 6000M 18 kg Splitter chassis weight exclu...

Page 77: ...IES 6000M 2160 Watts 60 Amps 36 to 72 Volts DC no tolerance Backplane IES 5106M The backplane has 10 1 Gigabit Ethernet ports IES 5112M The backplane has 20 1 Gigabit Ethernet ports IES 6000M The bac...

Page 78: ...ent sizes of fans two 6 cm and two 9 cm Fan Dimensions 60 mm W x 20 mm D x 60 mm H and 92 mm W x 25 mm D x 92 mm H The IES 5112M s fan module has six 9 cm fans Fan Dimensions 92 mm W x 25 mm D x 92 mm...

Page 79: ...tions from and to other devices See Section 2 7 on page 57 for more information about the ALARM module Certifications RoHS Compliance CE Conformity FCC ITU T K 20 Safety EN 60950 1 CSA 60950 1 UL 6095...

Page 80: ...Chapter 5 Product Specifications IES 5106M IES 5112M IES 6000M User s Guide 80...

Page 81: ...lity arising out of the application or use of any products or software described herein Neither does it convey any license under its patent rights nor the patent rights of others ZyXEL further reserve...

Page 82: ...this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a class A prod...

Page 83: ...atever extent it shall deem necessary to restore the product or components to proper operating condition Any replacement will consist of a new or re manufactured functionally equivalent product of equ...

Page 84: ...Appendix A Legal Information IES 5106M IES 5112M IES 6000M User s Guide 84...

Page 85: ...e main chassis splitter See splitter chassis connections alarm 59 line cards to splitter cards 41 power 59 copyright 81 critical alarm 59 D disclaimer 81 dressing the cables 61 DSL line cards See line...

Page 86: ...wer module 75 changing 73 connecting 74 disconnecting 72 power wire dressing 61 product description 13 product registration 83 PWR LED 63 R rack installation 19 specifications 76 registration product...

Page 87: ...Index IES 5106M IES 5112M IES 6000M User s Guide 87 W warranty 83 note 83 wire power 60...

Page 88: ...Index IES 5106M IES 5112M IES 6000M User s Guide 88...

Reviews: