IES-1248-51V Support Notes
81
Cascade two IES-1248-51V (Daisy chain mode)
You know, the IES-1248-51V is a remote mini-DSLAM. When the subscriber number
is increased, ISPs may cascade or daisy-chain the more then one IES-1248-51V to
extend the port number. They can daisy-chain up to three IES-1248-51V.
MDF
MDF
ISP/Central office
Internet
IES-1248-51V
IES-1248-51V (Daisy-chain mode)
How to setup Daisy-chain mode
In this case, we daisy-chain two IES-1248-51V. Please see the figure above. We only
set the one connected to the ISP as Daisy-Chain mode. In Daisy-Chain mode, connect
the Ethernet Port 1 to the Ethernet backbone and connect the Ethernet Port 2 to
another IES-1248-51V. Note that we don’t suggest using loop network topology while
using daisy-chain mode.
1. IES-1248-51V settings
Click
Basic Setting
,
Switch setup
in the navigation panel to display configuration
screen as shown. You will see the
Switch setup
page. In
Switch Mode
combobox,
select the
Daisy chain
. Don’t forget press
Apply
button to let the setting take effect.