background image

AN5516-06 

Optical Line Terminal Equipment 

Hardware Description 

Version: A 

Code: MN000000814 

ZyXEL 

FiberHome  

May 2011 

Summary of Contents for FiberHome AN5516-06

Page 1: ...AN5516 06 Optical Line Terminal Equipment Hardware Description Version A Code MN000000814 ZyXEL FiberHome May 2011...

Page 2: ...ces the key features supported by the AN5516 06 including GPON EPON access GPON EPON terminal management VLAN broadcast voice and safety and introduces these functions in details in terms of definitio...

Page 3: ...ding preparations precautions early operations operation process and subsequent operations so as to guide users with the completion of component replacement on the hardware AN5516 06 Optical Line Term...

Page 4: ...manual is intended for the following readers Planning and designing engineers Commissioning engineers Operation and maintenance engineers To utilize this manual these prerequisite skills are necessar...

Page 5: ...erface Card CES Mode CE1B 32 E1 Optical Interface Card CES mode type B PUBA Public Card type A HSWA Core Switch Card EPON card number 2 115 334 HU1A 4 GE 1 10GE Optical Interface Uplink Card HU2A 2 GE...

Page 6: ...1 14 2 PDP 2 1 2 1 Function 2 2 2 2 Structure 2 3 2 3 Power Connector 2 5 2 3 1 Main and Branch Power Supply Connector Posts 2 5 2 3 2 Automatic Circuit Breaker 2 6 2 4 Alarm Terminal 2 7 2 5 Lightni...

Page 7: ...15 PWR Card 4 44 5 Cable and Connector 5 1 5 1 Power Cable 5 2 5 1 1 Cabinet Power Cable 5 2 5 1 2 Subrack Power Cable 5 4 5 2 Protection Earth Ground Cable 5 6 5 2 1 Subrack Protection Earth Ground C...

Page 8: ...Appendix A Abbreviation A 1...

Page 9: ......

Page 10: ...panel 2 6 Figure 3 1 Subrack structure 3 2 Figure 3 2 An illustration of subrack configuration 3 3 Figure 3 3 The appearance of the fan unit 3 4 Figure 4 1 Appearance and structure of the EC4B card 4...

Page 11: ...n earth ground cable 5 7 Figure 5 8 The alarm cable for the head of row cabinet 5 8 Figure 5 9 The subrack alarm cable 5 9 Figure 5 10 The LC PC optical fiber connector 5 11 Figure 5 11 The SC PC opti...

Page 12: ...meter table 3 5 Table 4 1 Classification of the AN5516 06 Cards 4 2 Table 4 2 The AN5516 06card configuration table 4 7 Table 4 3 The HSWA card interfaces 4 9 Table 4 4 The HSWA card indicator LEDs 4...

Page 13: ...33 Table 4 32 The CE1B card interfaces 4 34 Table 4 33 The CE1B card indicator LEDs 4 34 Table 4 34 The CE1B card key 4 35 Table 4 35 The CE1B card technical specification 4 35 Table 4 36 The C155A ca...

Page 14: ...escription associated with the E1 interface pin 5 13 Table 5 4 The wiring scheme of the straight through network cable 5 17 Table 5 5 The wiring scheme of the cross over network cable 5 17 Table 5 6 D...

Page 15: ......

Page 16: ...Version A 1 1 1 Cabinet This chapter introduces the AN5516 06 cabinet and includes the following contents Appearance Size and weight Structure Typical layout Ventilation principle...

Page 17: ...ment Hardware Description 1 2 Version A 1 1 Appearance The AN5516 06 can be mounted in a 19 inch cabinet or a 21 inch cabinet Figure 1 1 illustrates the appearance of the 19 inch cabinet Figure 1 1 An...

Page 18: ...1 Cabinet Version A 1 3 Figure 1 2 illustrates the appearance of the 21 inch cabinet Figure 1 2 An illustration of the 21 inch cabinet...

Page 19: ...516 06 Optical Line Terminal Equipment Hardware Description 1 4 Version A Figure 1 3 illustrates the appearance of the 21 inch antidust cabinet Figure 1 3 An illustration of the 21 inch antidust cabin...

Page 20: ...600mm 4 102 596 94kg 2000mm 600mm 600mm 4 102 597 109kg 2200mm 600mm 600mm 4 102 598 117kg 2600mm 600mm 600mm 4 102 599 134kg 21 inch cabinet 1600mm 600mm 300mm 4 102 589 51kg 2000mm 600mm 300mm 4 102...

Page 21: ...inet are illustrated in Figure 1 4 1 Mounting hole for the top connection bent angle bracket 2 Wiring hole top 3 Ventilation hole area top 4 LED top 5 ESD protection earth ground fastener 6 Mounting h...

Page 22: ...ons of alarm indicator LEDs on the top of the 19 inch cabinet Color Meaning Status Description Red Emergency ON An emergency alarm in equipment OFF No emergency alarm in equipment Yellow Non emergency...

Page 23: ...g hole top 2 LED top 3 ESD protection earth ground fastener 4 Rear door 5 Wiring channel 6 Wiring hole bottom 7 Mounting hole on the vertical mounting flange 8 Front door 9 Mounting hole for the top c...

Page 24: ...of alarm indicator LEDs on the top of the 21 inch cabinet Color Meaning Status Description Red Emergency ON An emergency alarm in equipment OFF No emergency alarm in equipment Yellow Non emergency ON...

Page 25: ...le top 2 LED top 3 Wiring channel 4 Rear door 5 ESD protection earth ground fastener 6 Mounting hole on the vertical mounting flange 7 Wiring hole bottom 8 Front door 9 Mounting hole for the top conne...

Page 26: ...tatus of each alarm LED Table 1 4 Descriptions of alarm indicator LEDs on the 21 inch antidust cabinet Color Meaning Status Description Red Emergency ON An emergency alarm in equipment OFF No emergenc...

Page 27: ...ipment Hardware Description 1 12 Version A 1 4 Typical Layout Cabinets of different specifications can house different number of AN5516 06 subracks A cabinet can hold up to two subracks Figure 1 7 Typ...

Page 28: ...16 06 subrack 300 Empty 100 Empty 100 AN5516 06 subrack 300 Empty 100 PDP 100 AN5516 06 subrack 300 Empty 100 Empty 100 AN5516 06 subrack 300 Empty 100 PDP 100 AN5516 06 subrack 300 Empty 100 Empty 10...

Page 29: ...lation inside the cabinet is illustrated in Figure 1 9 and Figure 1 10 A flow of air is forced by the air guide unit at the lower part of the subrack into the cabinet After being blown by the fan unit...

Page 30: ...1 Cabinet Version A 1 15 Figure 1 9 An illustration of ventilation principle for a 19 inch cabinet...

Page 31: ...AN5516 06 Optical Line Terminal Equipment Hardware Description 1 16 Version A Figure 1 10 An illustration of ventilation principle for a 21 inch cabinet...

Page 32: ...Version A 2 1 2 PDP This chapter introduces the AN5516 06 PDP and includes the following contents Function Structure Power connector Alarm terminal Lightning protection module Specifications...

Page 33: ...516 06 is PDP296B It inducts two channels of 48V power active and standby from the external e g the power cabinet and provides three sets of redundant branch power rails six branch power rails totally...

Page 34: ...Figure 2 1 and Figure 2 2 Note After being installed with different mounting ears the PDP296B can be mounted in a 19 inch cabinet or a 21 inch cabinet Figure 2 1 The PDP structure Connectors switches...

Page 35: ...dicator LED of the PDP It can be set in the following two ways Short pin1 and pin2 of JP1 the green LED on the top of the cabinet will indicate the working status of the PDP Short pin2 and pin3 of JP1...

Page 36: ...the protection earth ground bus of the equipment room on one end and connects to the protection earth ground point on the top of the cabinet on the other end Table 2 2 introduces the branch power rail...

Page 37: ...rminal Equipment Hardware Description 2 6 Version A 2 3 2 Automatic Circuit Breaker The branch power automatic circuit breaker ACB is located on the front panel of the PDP as shown in Figure 2 3 Figur...

Page 38: ...LED on the cabinet top The alarm output terminal connected to the alarm LED on the cabinet top XS4 is a six conductor D type socket 2 5 Lightning Protection Module The hardware number of the power lig...

Page 39: ...larm according to the alarm signals illuminates the indicator LED on the cabinet top and outputs alarm signals to the upper layer device e g the head of row cabinet Differential mode protection Withst...

Page 40: ...Version A 3 1 3 Subrack This chapter introduces the AN5516 06 subrack and includes the following sections Structure Size and weight Subrack configuration Fan unit...

Page 41: ...structure and names of various components of the subrack are illustrated in Figure 3 1 Figure 3 1 Subrack structure 3 2 Size and Weight Table 3 1 shows the size and weight of the subrack Table 3 1 The...

Page 42: ...d on the upmost left side of the subrack It is dedicated for the fan card Other horizontal slots are distributed like this Slots 19 and 20 on the top of the subrack are specially for the uplink card S...

Page 43: ...igent progressive speed control with 8 speed choices Depending on the ambient temperature it changes the speed to adjust air flow and properly cool the equipment 3 4 2 Appearance The hardware number o...

Page 44: ...mption of the fan unit Table 3 2 Fan unit parameter table Item Parameter Fan size Width Height Depth 58 3 mm 244 3 mm 224 3mm Fan weight 1 84kg Fan power consumption The maximum power consumption is 6...

Page 45: ......

Page 46: ...s keys and technical specifications of all cards used in the AN5516 06 It includes the following sections Appearance and structure Card configuration table HSWA card EC4B card EC8B card GC4B card GC8B...

Page 47: ...earance and Structure The AN5516 06 cards can be classified into four categories as per the height of the card panels Table 4 1 Classification of the AN5516 06 cards Height of Card mm Example Card Ref...

Page 48: ...4 Card Version A 4 3 Figure 4 1 Appearance and structure of the EC4B card...

Page 49: ...AN5516 06 Optical Line Terminal Equipment Hardware Description 4 4 Version A Figure 4 2 Appearance and structure of the HU1A card...

Page 50: ...4 Card Version A 4 5 Figure 4 3 Appearance and structure of the PWR card...

Page 51: ...6 06 Optical Line Terminal Equipment Hardware Description 4 6 Version A Figure 4 4 Appearance and structure of the CIO card Note The card number is indicated in a tag attached to the lower part of the...

Page 52: ...tection CE1B 2 170 845 Provides 32 E1 uplink electrical interfaces Uplink card 19 20 HU1A 2 170 846 Provides four GE uplink optical electrical interfaces and one 10GE uplink optical interface HU2A 2 1...

Page 53: ...rts broadcast packet multicast packet and unknown packet suppression and prevents generation of broadcast storms on the network Supports port based and IEEE 802 1q based VLAN Supports flexible Q in Q...

Page 54: ...g normally Blinking slowly The card is initializing Blinking quickly The card is the standby unit and is executing a configuration command from the active card OFF The card has not been powered up ALM...

Page 55: ...tting the card K1 The panel side The mounting side Figure 4 5 The location of the key on the HSWA card Caution The reset operation may result in interruption of all services carried by the AN5516 06 T...

Page 56: ...q etc Working modes supported 10 100 1000Mbit s 10Gbit s full duplex Switching mode Store and Forward Capacity of the core switch card 488Gbit s Backplane switch rate 960Gbit s Maximum packet forwardi...

Page 57: ...local and remote loopback tests Provides OAM Supports automatic discovery and detection of ONUs Supports pre authorization and pre configuration of ONUs Supports ONU configuration in a batch manner P...

Page 58: ...between the active card and the standby card OFF The card has not been powered on or the software has not been started ALM Alarm indicator Red ON The card is resetting experiencing an alarm or has fa...

Page 59: ...May result in interruption of the connected ONU services of EPON interfaces 3 4 K3 Reset key of the card For card reset May result in interruption of all connected ONU services K1 K2 K3 The panel side...

Page 60: ...e and Forward Maximum package forwarding rate Wire speed forwarding MAC address 16k Buffer size 512Mbytes Maximum split ratio 1 64 Maximum LLID 256 Bandwidth allocation granularity 64kbit s Optical fi...

Page 61: ...local and remote loopback tests Provides OAM Supports automatic discovery and detection of ONUs Supports pre authorization and pre configuration of ONUs Supports ONU configuration in a batch manner P...

Page 62: ...shing a communication link between the active card and the standby card OFF The card has not been powered on or the software has not been started ALM Alarm indicator Red ON The card is resetting exper...

Page 63: ...course of the card maintenance and upgrade It is not recommended that the user directly issue a reset command using the reset key Technical Specification Table 4 14 The EC8B card technical specificati...

Page 64: ...y 64kbit s Optical fiber connector SC PC Network cable 1000BASE PX10 G 652 single mode fiber transmission distance 10km 1000BASE PX20 G 652 single mode fiber transmission distance 20km Power consumpti...

Page 65: ...s flexible QoS and SLA Provides FEC Supports local and remote loopback tests Provides OAM Supports automatic discovery and detection of ONUs Supports pre authorization and pre configuration of ONUs Su...

Page 66: ...r the software has not been started ALM Alarm indicator Red ON The card is resetting experiencing an alarm or has failed to establish a communication link between the active card and the standby card...

Page 67: ...e card maintenance and upgrade It is not recommended that the user directly issue a reset command using the reset key Technical Specification Table 4 18 The GC4B card technical specification Item Spec...

Page 68: ...PON Maximum Port ID 4k PON Bandwidth allocation granularity 64k Optical fiber connector SC PC Network cable G 652 single mode fiber Power consumption 44w Working temperature 0 to 45 Ambient temperatur...

Page 69: ...s flexible QoS and SLA Provides FEC Supports local and remote loopback tests Provides OAM Supports automatic discovery and detection of ONUs Supports pre authorization and pre configuration of ONUs Su...

Page 70: ...shing a communication link between the active card and the standby card OFF The card has not been powered on or the software has not been started ALM Alarm indicator Red ON The card is resetting exper...

Page 71: ...course of the card maintenance and upgrade It is not recommended that the user directly issue a reset command using the reset key Technical specification Table 4 22 The GC8B card technical specificati...

Page 72: ...Alloc ID 1k PON Maximum Port ID 4k PON Bandwidth allocation granularity 64k Optical fiber connector SC PC Network cable G 652 single mode fiber Power consumption 60W Working temperature 0 to 45 Ambie...

Page 73: ...ascaded to the IP network via a single IP port Interface description Table 4 23 The HU1A card interfaces Symbol Meaning Description XFP 10GE uplink optical interface Provides10GE uplink optical interf...

Page 74: ...LAN LED Green ON The WAN mode of 10GE interface OFF The LAN mode of 10GE interface Technical specification Table 4 25 The HU1A card technical specification Item Specification Network standard IEEE802...

Page 75: ...t Interface description Table 4 26 The HU2A card interfaces Symbol Meaning Description XG 10GE uplink optical interface Provides 10GE uplink optical interface and is connected with the IP network GE G...

Page 76: ...N WAN LAN LED Green ON The WAN mode of 10GE interface OFF The LAN mode of 10GE interface Technical specification Table 4 28 The HU2A card technical specification Item Specification Network standard IE...

Page 77: ...scade interface allowing multiple devices to be cascaded to the IP network via a single IP port Interface description Table 4 29 The GU6F card interface Symbol Meaning Description GE GE uplink optical...

Page 78: ...example switches OFF The port is not linked up Technical specification Table 4 31 TheGU6F card technical specification Item Specification Network standard IEEE802 3 IEEE802 3z etc Optical module inte...

Page 79: ...Meaning Description E1 E32 E1 interface Provides E1 interfaces and is connected with the transmission network CLIK IN Clock input interface For introduction of the external clock CLIK OUT Clock outpu...

Page 80: ...the CE1B card Caution The reset operation may result in interruption of all services carried by the CE1B card The reset operation is generally conducted in course of the card maintenance and upgrade...

Page 81: ...re Description 4 36 Version A Item Specification Delay Loopback delay 3ms Bit error ratio Free of bit error in 24 hours Power consumption 40W Working temperature 0 to 45 Ambient temperature for storag...

Page 82: ...CLIK IN1 Clock input interface The first external clock input CLIK IN2 Clock input interface The second external clock input CLIK OUT Clock output interface The external clock output 1 2 STM 1 uplink...

Page 83: ...up Blinking quickly The optical interface is transmitting or receiving data OFF The optical interface is not linked up MS1 2 Active standb y status LEDs Green ON The optical interface is active OFF T...

Page 84: ...ed that the user directly issue a reset command using the reset key Technical Specification Table 4 39 The C155A card technical specification Item Specification Network standard IEEE802 3 PWE3 G 825 W...

Page 85: ...Reserved for debugging Indicator LED description Table 4 41 The PUBA card indicator LEDs Symbol Meaning Color Status Description ACT Working status LED Green ON The card is working normally Blinking...

Page 86: ...enance and upgrade It is not recommended that the user directly issue a reset command using the reset key Technical Specification Table 4 43 The PUBA card technical specification Item Specification Ne...

Page 87: ...uipment ALM Alarm interface Outputs the alarm reported by the equipment to the PDP cabinet top or the head of row cabinet ESC Environment monitoring interface Connects to an external environment monit...

Page 88: ...Technical specification Table 4 46 The CIO card technical specification Item Specification Power consumption 2 W Working temperature 0 to 45 Ambient temperature for storage 30 to 60 Ambient humidity...

Page 89: ...upply Indicator LED description Table 4 48 The PWR card indicator LEDs Symbol Meaning Color Status Description ACT Working status LED Green ON The output of the power supply card is normal OFF The out...

Page 90: ...ntroduces various cables and connectors used by the AN5516 06 It includes the following sections Power cable Protection earth ground cable Alarm cable Fiber jumper Coaxial E1 cable Coaxial clock cable...

Page 91: ...he equipment The AN5516 06 cabinet power cable is composed of three cables each with a unique color The hardware number of the blue power cable the black power cable and the yellow green power cable a...

Page 92: ...al protection earth ground and the PE external power supply terminal on the PDP Its appearance is shown in Figure 5 3 Figure 5 3 The protection earth ground cable Figure 5 4 illustrates the connector...

Page 93: ...le Purpose The subrack power cable of the AN5516 06 is used to connect the PDP and the subrack power supply card and provide both the active and standby power supplies for the subracks The hardware nu...

Page 94: ...nd Connector Version A 5 5 Specifications Item Specification Cable type Double sheathed two core soft cable Color Sheath grey white wires blue black Maximum current 25A Conductor cross sectional area...

Page 95: ...protection earth ground cable is 3 696 084 The subrack protection earth ground cables have already been connected in the cabinet before delivery Appearance view The subrack protection earth ground cab...

Page 96: ...to the PE inside terminal of the PDP before delivery Appearance view The cabinet protection earth ground cable consists of a M6 copper tube uninsulated terminal which is connected to the PDP a M6 pre...

Page 97: ...quipment alarm signal from the cabinet to the head of row cabinet Its hardware number is 3 695 135R1A Appearance view The alarm cable for the head of row cabinet has a three conductor D type connector...

Page 98: ...he subrack alarm cables have already been connected in the cabinet before delivery Appearance view The subrack alarm cable is universal straight through network cable both ends of which are RJ 45 conn...

Page 99: ...pers Relevant Card Interface Purpose HU1A HU2A GU6F SFP XFP GE XG GE Provides GE and 10 GE optical channels to connect the IP network C155A STM 1 Provides STM 1 optical channel to connect the transmis...

Page 100: ...corresponding relationship between the AN5516 06 cards and the fiber jumper is shown in Table 5 2 Table 5 2 The corresponding relationship between the card and the fiber jumper Card Interface Fiber Ju...

Page 101: ...coaxial E1 cable includes 75 and 120 coaxial cables with regard to impedance The AN5516 06 uses the 75 E1 cable the hardware number of which is 3 695 442R2A Appearance view The end of the E1 cable co...

Page 102: ...core R5 7 9 Conductor core 30 Shield ground 22 Shield ground T1 14 2 Conductor core T5 6 10 Conductor core 29 Shield ground 21 Shield ground R2 13 3 Conductor core R6 5 11 Conductor core 28 Shield gr...

Page 103: ...ground Note 1 The copper foil inside the plastic casing is connected to the metal shell of the plug Note 2 Ri indicates the i th input and Ti indicates the i th output The pins not listed in this tab...

Page 104: ...er of the 75 coaxial clock cable is 3 695 187R1A Appearance view The end of coaxial clock cable connected with the AN5516 06 is a SAA type coaxial plug and the end connected with the MDF is composed o...

Page 105: ...t devices such as the network management computer and environment monitoring device Its hardware number is 3 695 095R4A Appearance view Both ends of the network cable are the RJ 45 connectors The netw...

Page 106: ...the straight through network cable Pin of the Local End X1 Wire Color Pin of the Opposite End X2 1 White orange 1 2 Orange 2 3 White green 3 4 Blue 4 5 White blue 5 6 Green 6 7 White brown 7 8 Brown 8...

Page 107: ...Line Terminal Equipment Hardware Description 5 18 Version A Specification Item Specification Cable type CAT 5 twisted pair Connector X1 X2 type RJ 45 Number of cores 8 Conductor diameter AWG 24 Breakd...

Page 108: ...local computer It is used for the aforesaid connection only when equipment commissioning is performed The hardware number of the serial port cable is 3 695 341R1A Appearance view The end of serial por...

Page 109: ...ship of the corresponding pins is shown in Table 5 6 Table 5 6 Definition of the serial port cable pins Connected Signal DE 9 Connector Pin RJ45 Connector Pin Tx 2 3 GND 5 4 5 Rx 3 6 Specification Ite...

Page 110: ...ity temperature fan vibration and access control The hardware number of the dry contact cable is 3 695 452R1A Appearance view The end of the dry contact cable connected with the DC1 to DC14 interface...

Page 111: ...1 level output end 3 Green Dry contact device 2 level output end 4 White green Dry contact device 3 level output end 5 Blue Dry contact device 4 level output end 6 White blue Dry contact device 5 lev...

Page 112: ...ork MGC Media Gateway Controller MGCP Media Gateway Control Protocol NGN Next Generation Network OAM Operation Administration and Maintenance ODN Optical Distribution Network OLT Optical Line Terminat...

Reviews: