Chapter 29 Access Control
ES-2024 Series User’s Guide
211
29.3.1 SNMP v3 and Security
SNMP v3 enhances security for SNMP management. SNMP managers can be required to
authenticate with agents before conducting SNMP management sessions.
Security can be further enhanced by encrypting the SNMP messages sent from the managers.
Encryption protects the contents of the SNMP messages. When the contents of the SNMP
messages are encrypted, only the intended recipients can read them.
29.3.2 Supported MIBs
MIBs let administrators collect statistics and monitor status and performance.
The Switch supports the following MIBs:
• SNMP MIB II (RFC 1213)
• RFC 1157 SNMP v1
• RFC 1493 Bridge MIBs
• RFC 1643 Ethernet MIBs
• RFC 1155 SMI
• RFC 2674 SNMPv2, SNMPv2c
• RFC 1757 RMON
• SNMPv2, SNMPv2c or later version, compliant with RFC 2011 SNMPv2 MIB for IP,
RFC 2012 SNMPv2 MIB for TCP, RFC 2013 SNMPv2 MIB for UDP
29.3.3 SNMP Traps
The Switch sends traps to an SNMP manager when an event occurs. The following tables
outline the SNMP traps by category.
An OID (Object ID) that begins with “
1.3.6.1.4.1.890.1.5.8.16
” (ES-2024A) or
“
1.3.6.1.4.1.890.1.5.8.27
” (ES-2024PWR) is defined in private MIBs. Otherwise, it is a
standard MIB OID.
Table 79
SNMP System Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
coldstart
coldStart
1.3.6.1.6.3.1.1.5.1
This trap is sent when the Switch is
turned on.
warmstart
warmStart
1.3.6.1.6.3.1.1.5.2
This trap is sent when the Switch
restarts.
fanspeed
FanSpeedEventOn
1.3.6.1.4.1.890.1.5.8.16.27.2.1 This trap is sent when the fan speed
goes above or below the normal
operating range.
FanSpeedEventClear
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the fan speed
returns to the normal operating
range.
temperature TemperatureEventOn
1.3.6.1.4.1.890.1.5.8.16.27.2.1 This trap is sent when the
temperature goes above or below
the normal operating range.
TemperatureEventClear
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the
temperature returns to the normal
operating range.
Summary of Contents for ES-2024 Series
Page 2: ......
Page 8: ...Safety Warnings ES 2024 Series User s Guide 8...
Page 20: ...Table of Contents ES 2024 Series User s Guide 20...
Page 28: ...List of Tables ES 2024 Series User s Guide 28...
Page 30: ...30...
Page 38: ...Chapter 2 Hardware Installation and Connection ES 2024 Series User s Guide 38...
Page 44: ...Chapter 3 Hardware Overview ES 2024 Series User s Guide 44...
Page 46: ...46...
Page 56: ...Chapter 4 The Web Configurator ES 2024 Series User s Guide 56...
Page 66: ...Chapter 6 Tutorials ES 2024 Series User s Guide 66...
Page 86: ...86...
Page 98: ...Chapter 9 VLAN ES 2024 Series User s Guide 98...
Page 104: ...Chapter 11 Static Multicast Forwarding ES 2024 Series User s Guide 104...
Page 136: ...Chapter 18 Port Authentication ES 2024 Series User s Guide 136...
Page 170: ...Chapter 22 AAA ES 2024 Series User s Guide 170...
Page 185: ...185 PART IV IP Application Static Route 187 Differentiated Services 191 DHCP 195...
Page 186: ...186...
Page 190: ...Chapter 25 Static Route ES 2024 Series User s Guide 190...
Page 202: ...202...
Page 226: ...Chapter 29 Access Control ES 2024 Series User s Guide 226...
Page 228: ...Chapter 30 Diagnostic ES 2024 Series User s Guide 228...
Page 232: ...Chapter 31 Syslog ES 2024 Series User s Guide 232...
Page 242: ...Chapter 33 MAC Table ES 2024 Series User s Guide 242...
Page 248: ...248...
Page 256: ...Appendix A Product Specifications ES 2024 Series User s Guide 256...
Page 268: ...Appendix C Legal Information ES 2024 Series User s Guide 268...