background image

T

T

C

C

T

T

3

3

0

0

3

3

F

F

 

 

T

T

h

h

e

e

r

r

m

m

o

o

m

m

e

e

t

t

e

e

r

r

 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

n

n

g

g

 

 

I

I

n

n

s

s

t

t

r

r

u

u

c

c

t

t

i

i

o

o

n

n

s

s

 

 

 

The thermometer is a non-contact infrared 

thermometer, also with Probe thermometer. You 
can select only one Mode at the same time but 
can change the Mode at will. Please remember to 
keep away from baby and children and don’t use it 
for safety related applications.   
 

* Special Features:   
  1. HACCP Zone Display;  
  2. Splash Proof (IP65)

 

 
 

In Non-contact Infrared Thermometer function (IRT Mode)

 

# The white light will automatically turns on while the Scan button is pressed. 

Simply aim the thermometer at the measure target with “Infrared Lens” 
and press Scan (infrared) key to display the surface temperature. The 
distance to target ratio is 2.5:1 therefore the thermometer should be 
positioned as close to the target as possible.

   

 

While scanning, the newest temperature will be updated on the LCD and the measurement will continue as long as 
the Scan (infrared) key is depressed. When the Scan (infrared) key is released, icon “Hold” will appear on the display 
and the last measurement will remain visible for 15 seconds before the display goes blank. 
 

Mode Selection     

 

MIN 

Æ

 MAX 

Æ

 LOCK 

Æ

 

o

C/ 

o

Æ

 EMIS 

 

MINIMUM OR MAXIMUM MODE 

The thermometer will display the minimum or maximum reading during the measurement period only until the Mode 
key is pressed. 
To utilize the minimum mode, please press Scan (infrared) key 

Æ

 Mode key 

Æ

 Scan (infrared) key. And keep 

pressing Scan (infrared) key for measurement.   
To utilize the maximum mode, please press Scan (infrared) key 

Æ

 Mode key *twice

Æ

 Scan (infrared) key. And keep 

pressing Scan (infrared) key for measurement. 

LOCK MODE 

The lock mode is particularly useful for continuous monitoring of temperatures. The thermometer will continuously 
display the temperature for up to 60 minutes or until the Scan (infrared) key button is pressed. 
To utilize the lock mode, please press Scan (infrared) key 

Æ

 Mode key *three times

Æ

 Scan (infrared) key.   

o

C OR 

o

F MODE 

To change the ‘

o

C’ or ‘

o

F’ mode, please press Scan (infrared) key 

Æ

 Mode key *four times

Æ

 Scan (infrared) key. 

Same steps can be taken when switching from 

o

F to 

o

C. 

EMISSIVITY 

The infrared thermometer is supplied with a default emissivity of 0.95. The emissivity can be changed from 0.10 (10E) 
to 1 (100E). Changes should only be carried out by experienced personnel. For information relating to the emissivity 
of specific materials, please contact the nearest retailer. Note: non-contact infrared thermometers are not 

recommended for use in measuring the temperature of shiny or polished metals. 
To change the emissivity, please Scan (infrared) key 

Æ

 Mode key *five times

Æ

 Scan (infrared) key for each 0.01 

(1E) adjustment

Æ

 Mode key. 

 

In Contact Thermocouple Probe function (COT Mode) 

Attach the thermometer at the measure target with “Probe” and press Probe key to continuously display the 
temperature for up to 4 minutes. After that the device will automatically shut off to extend the battery life. Press Probe 
key will interrupt the scanning to display the last temperature with a 'Hold' wording. To reenter scanning just press 
Probe key again. 

  1. Do not twist the probe and rotate the probe in wrong direction. 

2. Over stress on probe may cause break. 
3. After measure high temp, the probe may remain HOT for a while. 
4. Probe is dangerous for human when the probe is in an open position. Remember to hold the probe back 

when not in use.   

  The probe of contact thermometer may be damaged if  exceeding the specification of measurement 

temperature range.   

 

 

To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding   

      24V AC RMS or 60V DC  with the thermocouple probe. 

 

HACCP check 

 

The “HACCP CHECK” feature is incorporated in our thermometer 
temperature to graphically indicate critical temperature zone. The icons 
and LED indicators located above the display indicate a food product 
stays in a safe or unsafe HACCP “ Danger Zone” temperature. The 
green and red LED light will always be lit before power off.   
 
A Green LED appears with icon ” 

  ” indicates a safe cool or frozen 

condition below 4

o

C(40

o

F) or appears with icon ” 

  ” indicates a safe 

holding temperature above 60

o

C(140

o

F). 

 
When temperature is between 4

o

C and 60

o

C, the red LED with icon ” 

  ” will appear and indicate that the temperature is fallen within the 

HACCP “Danger Zone” from 4

o

C to 60

o

C (40~140

o

F)

.

 

 

 

 

 

 
 

LCD ERROR MESSAGES 

The thermometer incorporates visual diagnostic messages as follows: 

 

 

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the 
measurement range. 

 

‘Er2’ is displayed when the thermometer is exposed to rapid changes in the 
ambient temperature. ‘Er3’ is displayed when the ambient temperature exceeds 
0

o

C (32

o

F) or +50

 o

C (122

 o

F). The thermometer should be allowed plenty of time 

(minimum 30 minutes) to stabilize to the working/room temperature. 

 

For all other error messages it is necessary to reset the thermometer. To reset it,

 

waiting for auto 

power off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn 
on. If the error message remains please contact the Service Department for further assistance. 

Distance:Spot (FOV)= 2.5:1 

Emissivity = 0.1~1 Step.01 
Wave Length = 8um-14um 

Reviews: