6.2
Connections
1. Connect and screw door lock(s), push button(s) or sensor(s) wires to the provided two-wire terminal connectors.
2. Insert wired terminal connectors into the matting sockets on PCB (Figure 6-2).
3. Connect POE/LAN cable to RJ-45 socket.
4. Connect door lock to
‘REL 1’
(
Relay 1)
and/or
‘REL 2’
(
Relay 2)
.
5. If an external switch button is used (See also Chapter 7.5: Web GUI Door Functions -> Sensor), connect the
external switch button wires to
‘SEN 1’
(
Sensor 1)
and/or
‘SEN2’
(
Sensor 2
)
Attention: NO/NC Jumper Position.
1.
Relay 2:
Closed/Jumperd center
Pin (2) + ’NO’- (1) means the ‘Normally open’ relays status in powered mode.
Closed/Jumperd center
Pin (2) + ’NC’ - (3) means the ‘Normally Close’ relays status in powered mode.
2.
Relay 1 works in Normally Open mode only.
For the safety reason and to avoid electrical damage to the unit. All Power source like an external power supply
or POE
must
be disconnected during installation process.
Note: The External Power Supply is not included in standard ZIP10-X package