Handheld Multi Gas Detector Operating Instructions 

Model: ZG9 

Product Overview 

Thank you for selecting ZG9 handheld multi gas detector. The ZG9 is designed to simultaneously measure 
multiple gas concentrations in the ambient environment. With long-term data storage, the user can assess the 
environmental friendliness. When ZG9 measures the gas concentration reaching the alarm setting or higher, 
the data display and alarm functions are activated. ZG9 is equipped with an RS485 interface for connecting to 
a computer for remote monitoring so as to reduce the risk of exposure to high concentrations of harmful 
gases and avoid harm to human health. ZG9 can be used in a wide range of industries, which include 
paint-related industries, wineries, related industries of CO2, food industry, laboratory, construction industry, 
etc. 

Features:

 

V

 

Dual beam NDIR (Non-Dispersive-Infrared) technology is used to measure CO

concentration and 

improve the long term stability.

 

V

 

Measure CO

2

, CO, VOC, PM2.5, PM10, RH, DP, AMB, Barometer 

V   Large LCD for easy reading of gas concentration and temperature and humidity. 

V

 

Audible alarm 

V

 

Data logging with SD card

 

V   Through the RS485 interface connection, multiple ZG9 units can be connected to the back-end computer 

system as a security monitoring application.

 

V   Built in the LCD backlight for easy reading in the dark.

 

V   This device is supplied with Li- ion 18650 3.7V rechargeable batteries, can be used for a long time.

 

 

A. Power Key 

B. Humidity Sensor 

C. Temperature Sensor 

D. LCD 

E. Charge Lamp 

F. M1 (Zone 1 Mode Key) 

G. UP\TWA\STEL\Max\Min 

H. M2 (Zone 2 Mode Key) 

I. Enter 

J. DOWN\ALTI 

K. Log (Data Logger) 

L. USB Socket 

M. SD Card Slot 

N. RS485 Jack 

O. Battery Cover 

P. Stand 

Q. Screw Position  R. Tripod Screw 

 

 

 
Key description: 

M1 (

F

Zone 1 sensor selection (CO

2

, CO, VOC, AMB) 

M2 (

H

Zone 2 sensor selection (CO

2

, CO, VOC, RH, DP, AMB, PM2.5, PM10) 

  (

G

TWA (CO

2

, 8-hr time weighted average), STEL (CO

2

, 15 min. weighted average), MAX, MIN 

  (

J

ALTI (Atmospheric pressure) 

Enter (

I

Execute a command or select options. 

Log (

K

Data logger

 

 
LCD display symbol description:

 

Symbol Description 

Basic

 

Optional

 

 

CO

concentration, parts per million (ppm)

 

 

 

CO concentration, parts per million (ppm)

 

 

 

VOC concentration, parts per billion (ppb) 

 

 

PM2.5 dust concentration

 (µg/m

3)

 

 

 

PM10 dust concentration (µg/m

3)

 

 

 

Battery capacity 

 

 

Atmospheric pressure 

 

 

Time weighted average (8 hours) 

 

 

Short

­

Term Exposure Limit   

(15 min. weighted average) 

 

 

Maximum value 

 

 

Minimum value 

 

 

Ambient temperature

 

 

 

Relative humidity 

 

 

Dew point 

 

 

Real-time setting display 

 

 

Year 

display

 

 

 

High/low gas concentration calibration 

 

 

High/low gas concentration alarm 

 

 

Display cycle 

 

 

SD card 

 

 

Operation Instructions 

Power on: 

Switch the Power Key (

A

) on. 

 
Measurement: 

After power on, the device starts to measure and update the data every second. 
Press the “

M1

” key (

F

) to switch the Zone 1 sensor display. (CO

2

CO

VOC

AMB) 

Press the “

M2

” key (

H

) o switch the Zone 2 sensor display.   

(CO

2

CO

 VOC

 RH

DP

AMB

PM2.5

PM10)

 

 
Backlight: 

The backlight appears on the screen during startup and operation. After the device is idle for 30 seconds, the 
backlight is automatically turned off to extend battery life. 

 
Display all sensor readings 

Press the “

M2

” key (

H

) for more than 3 seconds and the screen displays

. Zone 2 displays readings 

of all sensors sequentially in time intervals. If you need to increase the display interval time, long press the 

M2

” key (

H

).The interval time will automatically increase    (1+0.5+0.5….. max. 10 seconds) , and release 

the “

M2

” key (

H

), the readings will be displayed according to the last set interval. If press the “

M2

” key (

H

again for more than 3 seconds, the

  function can be cancelled. 

         

 

 
Real-time setting: 

Long press the “

M1

” key (

F

) to proceed the date and time setting. The default format is 24-hour. Press the 

(

G

)/

(

J

)” key to edit the parameters, and press the “

Enter

” key (

I

) to proceed the next setting. The 

setting sequence is: year

month

date

hour

minute. After finishing the real-time setting, press the “

M1

” 

key (

F

) to continue the alarm setting.

 

         

         

 

 
Alarm settings: 

The setting order of the sensors is CO

2

CO

VOC

PM2.5

PM10. Press the "Enter" key (

I

) to switch 

the high/low gas concentration alarm setting. Press “

(

G

)/

(

J

)” key to edit the parameters, and then 

press the “

M1

” key (

F

) to proceed the next sensor alarm value settings. After settings, press and hold the 

M1

” key (

F

) to return to the main screen.

 

 

 
Sensor warm-up time and logging Interval: 

 
Data logging: 

Press the “

Log

” key (

K

) for 3 seconds and the screen displays 

  to start the data logging function. If long 

press the “

Log

” key (

K

),this function can be canceled. When 

  flashes, it means that the SD card is 

broken or full; when 

  remains stationary, it indicates normal operation.

 

 
 
 
 
 

 

Data logging interval time setting: 

The default interval time is 00:02 (2 seconds). Press the “

Log

” key (

K

) for more than 3 seconds and then the 

interval time will automatically increase. The interval time, loop display, ranges from 00:02 seconds to 60:00 
minutes and then back to 00:02 seconds. 

The interval time  5 minutes, the buzzer on/off switch is controlled 

by the “

Enter

” key (

I

)

; the interval time is  5 minutes, the buzzer is off. 

         

 

 
 

°C/°F

 

switch: 

When the temperature is displayed on the screen, press the "

" key (

G

) to switch 

°

C/°F. 

 
Atmospheric pressure display: 

Press "

" key (

J

), and then press "

" key (

G

) to select 

Altitude (M) 

 Altitude (ft) 

 

Barometer 

(mmHg)

. The display returns to the main screen after 10 seconds. 

 
Atmospheric pressure compensation: 

Press and hold the "

" key (

J

) to turn the compensation function on/off. The gas compensation is only for 

CO

2.

 

 
Buzzer on/off: 

Press the “

Enter

” key (

I

) to turn the buzzer on/off. During

  operation, if 

AL L

 or 

AL H

 buzzer 

sounds, 

 stops to operate. At this time, press the “

Enter

” key (

I

) to turn off the buzzer and 

continue

. In addition, the buzzer will be automatically turned off when the data logging interval time 

is 

5 minutes. 

Buzzer AL L/AL H: 

When 

AL L

 is on, the buzzer sounds "Ta Ta Ta"; when 

AL H

 is on, the buzzer sounds "Bi Bi Bi". 

No. Sensor Warm-up 

time 

Data logging interval time setting 

After powering on and standby time, 
data logging can be operated. 

Data logging interval 
time setting 

1 CO

2

 

1 minute 

After power on 5 minutes 

2

 

seconds~60

 

minutes 

CO 

5 minutes 

After power on 5 minutes 

2 seconds~60 minutes 

VOC 

5~15 minutes 

After power on 20 minutes 

2 seconds~10 minutes 

PM2.5 

PM10 

1 minute 

After power on 5 minutes 

2

 

seconds~60

 

minutes 

(Display Features and Modes) 