background image

1.

搬运提手

Carry Handle

2.

设备开关

Device switch

3.

电池

BMS

开关

Battery BMS switch

4.AC

充电输入端口

AC Charge Input Port

5.AC

输出端口

AC Output Port

6.PV

充电输入端口

PV Charge Input Port

7.

移动脚轮

Movable wheels

8.LCD

操作触控显示屏

LCD operate touch display screen

3. INSTALLATION

安装

3.1 Unpacking and Inspection

开箱检查

Before installation,please inspect the unit. Be sure that everything in the package is not

damaged. The following items inside of package would be received.

安装前,请检查设备。确保

包装中的所有物品均未损坏。包装内的以下物品将被接收。

01.

逆变器

Inverter 02.

使用手册

User manual 03.

产品保修卡

Product warranty card

3.2 Preparation

准备

Please remove the two screws on the back cover of the device before opening it.

打开设备之

前,请先详细阅读使用手册。

3.3 Installation sites selection

安装地点选择

Consider the below points before selecting where to install:

在选择安装位置之前,考虑以下几点

1.Do not mount the inverter on the surface of flammable construction materials.

请勿将机器安装在易燃的建筑材料表面。

2.Mount on the surface of solid material.

安装在固体材料的表面。

3.

Install this inverter at a visible place in order to allow the LCD display to be read at all

times.

将此逆变器安装在可见的地方,以便始终读取

LCD

显示屏

4.

For proper air circulation and heat dissipate,make sure there is 20 cm distance from the

two side, 50 cm distance from bottom of the unit.

为确保适当的空气流通和散热,请确保距

设备两侧的距离为

50 cm

5.

The ambient temperature should be between 0°C and 55°C to ensure optimal operation.

环境

温度应在

0°C

45°C

之间,以确保最佳操作。

6.

The recommended installation position is to be adhered to the wall vertically.

建议的放置位置

平面无杂物地面。

7.

Be sure to keep other objects and surfaces as shown in the diagram to guarantee

sufficient heat dissipation and to have enough space for collecting wires.

请确保如图所示

保持其他物体和表面,以确保足够的散热并有足够的空间收集电线。

3.4 AC Input/Output Connection AC

输入

/

输出连接

CAUTION!

Before connecting to AC input power source, please install a separate AC

breaker between inverter and AC input power source. This will ensure the inverter can be

securely disconnected during maintenance and fully protected from over current of AC

input. The recommended spec of AC breaker is 32A for 3KVA and 50A for 5.5KVA. There

Summary of Contents for GENIXGREEN

Page 1: ...3 2KVA INVERTER 5KWH LFP BATTERY ALL IN ONE SOLAR ESS USER MANUAL...

Page 2: ...UNIT 3 4 AC AC INPUT OUTPUT CONNECTION 3 5 PV PV CONNECTION 3 6 FINAL ASSEMBLY 4 OPERATION 4 1 POWER SWITCH 4 2 OPERATION AND DISPLAY PANEL 4 3 LCD LCD DISPLAY ICONS 4 4 LCD LCD SETTING 4 5 PARALLEL F...

Page 3: ...sconnecting all power supply before any maintaining or cleaning please noted that if you only turn off the unit are not safe enough 4 WARNING Only qualified service persons are allowed to operate this...

Page 4: ...r Charger priority via LCD setting LCD AC 5 Smart battery charger design for optimized battery performance 6 Compatible to mains voltage or generator power 7 Overload Over temperature Short circuit pr...

Page 5: ...Figure 1 Hybrid Power System 2 3 Product Overview...

Page 6: ...nstall this inverter at a visible place in order to allow the LCD display to be read at all times LCD 4 For proper air circulation and heat dissipate make sure there is 20 cm distance from the two sid...

Page 7: ...ion to use appropriate cable for PV module connection To reduce risk of injury please use the proper recommended cable size as below Model Gauge Cable mm2 Torque Value 3 2KVA 10AWG 6 1 2 Nm WARNING Be...

Page 8: ...sc 84A SOLAR INPUT Qty of Panels Total input Power Min in serial 6 pcs max in serial 12 pcs 6 12 6 pcs in serial 6 6 pcs 1500W 9 pcs in serial 9 9 pcs 2250W 12 pcs in serial 12 12 pcs 3000W 9 pieces i...

Page 9: ...ay panel shown in below chart is on the front panel of the inverter It includes three indicators four function keys and a LCD display indicating the operating status and input output power information...

Page 10: ...ration information include fault and warning code Input voltage and frequency information Output voltage and frequency information PV voltage and power information Battery voltage and current informat...

Page 11: ...nput output battery AC charging MPPT parallel date and time peak valley and other function settings MPPT This button includes generation and event This button includes LCD inverter MPPT version LCD MP...

Page 12: ...sufficient for load batteries and solar will supply power at the same time When solar energy and batteries are insufficient or solar energy is unavailable AC power supply power to the load Battery Bat...

Page 13: ...efault 42 0Vdc Settings range from 36V or 18V of 24V of 48V to 50V or 25V of 24V of 48V Settings increase or decrease by 0 1V 42 0Vdc 48V 36V 24V 18V 48V 50V 24V 25V 0 1V Equalized charging voltage de...

Page 14: ...local date and time in your country On grid choose Choose the solar mode first then choose grid mode when in grid mode PV will power load first then extra power feed to AC when PV power is not enough...

Page 15: ...5 Fault Reference Code Fault code Fault event 01 Bus voltage is too high 02 Inverter voltage is too high 03 Inverter voltage is too low 04 Bus soft start failure 05 Overload fault 06 Output short circ...

Page 16: ...ocess LCD LED and buzzer will be active then complete off LCD LED The battery voltage is too low 1 Re charge battery 2 Replace battery No response after power on No indication 1 The battery voltage is...

Page 17: ...red LED is on LED warning code 06 06 Fan fault Replace the fan warning code 05 05 Internal temperature of inverter component is over 100 C 100 C Check whether the environment around the equipment wel...

Page 18: ...ted load Fault code 02 03 02 03 Output abnormal Inverter voltage below than 190Vac or is higher than 260Vac 190Vac 260Vac 1 Reduce the connected load 2 Return to repair center Fault code 01 04 06 08 0...

Page 19: ...tor 1 0 Efficiency DC AC DC AC 92 Frequency 50 60HZ Overload protection MPPT will close immediately as long as the input power is greater than the maximum output power MPPT Max input current 19 6A Max...

Page 20: ...aker Max AC charge current 60A Optional 10A to 60A 10A 60A Efficiency Line Mode 95 Rated R load battery full charged R Transfer Time 10ms Communication WIFI Humidity 0 90 RH No condensing Operation te...

Page 21: ...25mA 200uA Table 4 Inverter Mode Specifications Battery system voltage 51 2V Waveform pure Sine wave Output Voltage Regulation 230Vac 5 Output Frequency 50 60Hz 1Hz Peak Efficiency 90 Power factor 1...