Warning code

警告码

Warning Event

警告事件

01

Battery voltage is too low

电池电压过低

02

Input voltage is too low

输入电压过低

03

Input voltage is too high

输入电压过高

04

Overload

过载

05

Over temperature

过温

06

Fan is locked when inverter is on

逆变器开启时风扇被锁定

07

Battery voltage is too high

电池电压过高

5.

TROUBLE SHOOTING

故障排除

Problem

问题

LCD/LED/BuzzerLC

D / LED /

蜂鸣器

Possible cause

可能

的原因

What to do

措施

Unit shuts down

automatically

during start up

process

设备在启

动 过 程 中 自 动 关

LCD/LED

and

buzzer will be active

then complete off

LCD / LED

和蜂鸣器

将激活,然后关闭

The battery voltage

is too low

电池电压过

1. Re-charge battery.

给 电

池充电。

2. Replace battery

更 换 电

No response

after power on

开机后无反应

No indication

无指示

1. The battery

voltage is too low.

池电压过低。

2. Internal fuse

tripped

内部保险丝

跳闸

1. Contact repair center

for replacing the fuse.

系维修中心更换保险丝

2. Re-charge battery.

电池充电。

3. Replace battery

更换电

Mains exist but

the unit works in

battery mode

在电源,但本机
以电池模式工作

Input voltage is

displayed as ‘0’

on the LCD and

green LED is

flashing

LCD

上的输入电压

显示为

“ 0”

,并且

绿色

LED

闪烁

Input protector

is triggered

入保护器被触

Check if AC breaker is

turned on and AC wiring

is connected well.

检查交

流断路器是否已打开并且
交流接线是否连接正确。

Summary of Contents for GENIXGREEN

Page 1: ...3 2KVA INVERTER 5KWH LFP BATTERY ALL IN ONE SOLAR ESS USER MANUAL...

Page 2: ...UNIT 3 4 AC AC INPUT OUTPUT CONNECTION 3 5 PV PV CONNECTION 3 6 FINAL ASSEMBLY 4 OPERATION 4 1 POWER SWITCH 4 2 OPERATION AND DISPLAY PANEL 4 3 LCD LCD DISPLAY ICONS 4 4 LCD LCD SETTING 4 5 PARALLEL F...

Page 3: ...sconnecting all power supply before any maintaining or cleaning please noted that if you only turn off the unit are not safe enough 4 WARNING Only qualified service persons are allowed to operate this...

Page 4: ...r Charger priority via LCD setting LCD AC 5 Smart battery charger design for optimized battery performance 6 Compatible to mains voltage or generator power 7 Overload Over temperature Short circuit pr...

Page 5: ...Figure 1 Hybrid Power System 2 3 Product Overview...

Page 6: ...nstall this inverter at a visible place in order to allow the LCD display to be read at all times LCD 4 For proper air circulation and heat dissipate make sure there is 20 cm distance from the two sid...

Page 7: ...ion to use appropriate cable for PV module connection To reduce risk of injury please use the proper recommended cable size as below Model Gauge Cable mm2 Torque Value 3 2KVA 10AWG 6 1 2 Nm WARNING Be...

Page 8: ...sc 84A SOLAR INPUT Qty of Panels Total input Power Min in serial 6 pcs max in serial 12 pcs 6 12 6 pcs in serial 6 6 pcs 1500W 9 pcs in serial 9 9 pcs 2250W 12 pcs in serial 12 12 pcs 3000W 9 pieces i...

Page 9: ...ay panel shown in below chart is on the front panel of the inverter It includes three indicators four function keys and a LCD display indicating the operating status and input output power information...

Page 10: ...ration information include fault and warning code Input voltage and frequency information Output voltage and frequency information PV voltage and power information Battery voltage and current informat...

Page 11: ...nput output battery AC charging MPPT parallel date and time peak valley and other function settings MPPT This button includes generation and event This button includes LCD inverter MPPT version LCD MP...

Page 12: ...sufficient for load batteries and solar will supply power at the same time When solar energy and batteries are insufficient or solar energy is unavailable AC power supply power to the load Battery Bat...

Page 13: ...efault 42 0Vdc Settings range from 36V or 18V of 24V of 48V to 50V or 25V of 24V of 48V Settings increase or decrease by 0 1V 42 0Vdc 48V 36V 24V 18V 48V 50V 24V 25V 0 1V Equalized charging voltage de...

Page 14: ...local date and time in your country On grid choose Choose the solar mode first then choose grid mode when in grid mode PV will power load first then extra power feed to AC when PV power is not enough...

Page 15: ...5 Fault Reference Code Fault code Fault event 01 Bus voltage is too high 02 Inverter voltage is too high 03 Inverter voltage is too low 04 Bus soft start failure 05 Overload fault 06 Output short circ...

Page 16: ...ocess LCD LED and buzzer will be active then complete off LCD LED The battery voltage is too low 1 Re charge battery 2 Replace battery No response after power on No indication 1 The battery voltage is...

Page 17: ...red LED is on LED warning code 06 06 Fan fault Replace the fan warning code 05 05 Internal temperature of inverter component is over 100 C 100 C Check whether the environment around the equipment wel...

Page 18: ...ted load Fault code 02 03 02 03 Output abnormal Inverter voltage below than 190Vac or is higher than 260Vac 190Vac 260Vac 1 Reduce the connected load 2 Return to repair center Fault code 01 04 06 08 0...

Page 19: ...tor 1 0 Efficiency DC AC DC AC 92 Frequency 50 60HZ Overload protection MPPT will close immediately as long as the input power is greater than the maximum output power MPPT Max input current 19 6A Max...

Page 20: ...aker Max AC charge current 60A Optional 10A to 60A 10A 60A Efficiency Line Mode 95 Rated R load battery full charged R Transfer Time 10ms Communication WIFI Humidity 0 90 RH No condensing Operation te...

Page 21: ...25mA 200uA Table 4 Inverter Mode Specifications Battery system voltage 51 2V Waveform pure Sine wave Output Voltage Regulation 230Vac 5 Output Frequency 50 60Hz 1Hz Peak Efficiency 90 Power factor 1...

Reviews: