background image

Z400BZ

INSTALLATION INSTRUCTIONS

Zurn  Industries,  LLC

 

|

 

Specification  Drainage  Operation

1801 Pittsburgh Avenue, Erie, PA  U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929
In  Canada

 

|

 

Zurn  Industries  Limited

3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292

www.zurn.com

Rev.

A

Date:

04/06/2018

C.N. No.

139849

Form  No. FD86

®

Dimensional Data (inches and [mm]) are Subject to Manufacturing Tolerances and Change Without Notice

Page

 1 of 2

Step 1

Loosen and remove the three #8-32 x 1/4 [6] lg. flat head
strainer screws  A  that secure the strainer  B  to the
frame.  D

Step 2

Remove the strainer.  B

Step 3

Loosen but do not remove the three #8-32 x 3/4 [19] lg.
flat head screws that secure the frame  D  to the
head.  F

Step 4

Using a 1/8” allen wrench, insert the allen wrench
through any of the six guide holes in the frame  D
to engage the #10-32 x 3/4 [19] lgflat head leveling
screws.  E

Step 5

Turn the allen wrench counter-clockwise to loosen and
raise the leveling screw  E  underneath the frame.  D

Step 6

Repeat with all six leveling screws  E  as necessary.
The leveling screws  E  can be used to raise the entire
frame  D  a set height or to adjust the frame  D
positioning to make level with the finished floor.