background image

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability 

is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a 

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists 

are approximate and are not guaranteed.

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

Z-LIGHT-W1

Zurn Smart Occupancy Light 

Installation, Operation, Maintenance

and Parts Manual

Patented and Patents Pending

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

For Commercial and Institutional Use Only

Summary of Contents for plumbSMART Z-LIGHT-W1

Page 1: ...shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the...

Page 2: ...This Page Intentionally Left Blank ...

Page 3: ...e FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment uses and can radiate radio frequency energy and if not installed and used in accordance with the in structions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installati...

Page 4: ...lage préjudiciable et 2 CE dispositif doit accepter tout brouillage reçu y compris un brouillage susceptible de provoquer un fonctionnement indésir able Radiation Exposure Statement This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment This equipment must be installed and used with a minimum distance of 10 mm between the radiator and your body NOTE I...

Page 5: ...ge 1 Zurn Smart Occupancy Light Part List Recommended Tools Extension Pole If ordered Mounting Bracket Occupancy Light Screwdriver Applicable Screw For installing surface 8 or M4 Anchor Optional Hand Drill 1 2 7 64 Drill Bits ...

Page 6: ...ecommended installation for each light unit is 6 inside the stall door without any visual obstructions within the light unit s 60 degree field of view Any deviation from recommended installation placement and height may impact product accuracy Ceiling 8 6 Partition Floor Wiring Diagram Breaker Panel Zurn Z PWRSUP W1 Power Supply Enclosed Junction box Occupancy Light Insert into 12 VDC Zurn Smart O...

Page 7: ...GW WRP W1 ETH gateway to a standard wall socket using the included power supply as shown on the right Placement LTE Gateway The ZGW WRP W1 LTE wireless gateway uses a cellular wide area network connection To improve quality place the gateway away from large metallic structures or sources of significant electrical interference like large transformers motors or florescent lighting ballasts Ethernet ...

Page 8: ...nected to the plumbSMART portal until you install your gateway Please follow the instructions below to contact Zurn prior to registering your devices Connecting to the plumbSMART Portal 1 Visit www zurn com plumbSMART connect to save time and money on your installation You can also call us at 844 987 6737 2 Provide the serial number and contact name email address and basic information about the in...

Page 9: ...mount bracket in place with 4 x 8 screws or 4 x M4 screws Be careful not to over tighten the screws to mitigate any ceiling or mount damage 6 Arrow Pointing Perpendicular to Stall Door Inside of stall door Door Water Closet The ceiling mount will come with a WC sticker indicating the direction of the arrow allowing the angle of orientation to be checked when the extension tube is in place Ceiling ...

Page 10: ...o assemble the unit If using a Zurn Smart Occupancy Light Mount Extension Pole feed the power cables though the extension tube until you see them visibly protruding out of the bottom extension cone Orient the extension pole mount arrow located in the bottom of the extension cone to an 11 o clock position with the ceiling mount bracket arrow already installed at a 12 o clock position on the ceiling...

Page 11: ... power supply Note When daisy chaining multiple lights off one power supply each light must be installed to maintain electrical connection for the entire network of lights If a light needs to be replaced it is best to remove the old light when a new one is available for replacement You may alternately install multiple lights using a hub and spoke method Note The dip switch on the bottom in the ima...

Page 12: ...ruction Ceiling Step 6 Once the cables are secured into the power block attach the light unit to the bottom of the light mount extension pole or ceiling mount bracket If using a light mount extension pole ensure that you are holding the extension tube when twisting on the light unit to prevent any misalignment from assembly IMPORTANT Orient the indented arrow on the bottom of the light at an 11 o ...

Page 13: ...ettings EzSetting Play via URL or equivalent 4 Navigate to https plumbsmart zurn com display activate 5 Save URL 6 Device will ask to reboot to apply settings Select Yes 7 Follow on screen instructions a Navigate to https plumbsmart zurn com admin displays on your computer phone or tablet b Enter the displays unique activation code c If activation takes longer than 2 minutes reload the web page on...

Page 14: ...isconnect lights from output terminals at power supply and measure open circuit voltage If open circuit voltage is normal inspect downstream wiring and connections for possible short circuit conditions If open circuit voltage is low replace power supply One light in a chain does not turn on when power is applied Damaged Device Measure voltage at device power input terminals If voltage is nominal a...

Page 15: ...This Page Intentionally Left Blank ...

Page 16: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 10 14 21 C N No 143368 Prod Dwg No FV781 ...

Reviews: