background image

PAGE 1 OF 4

ZURN INDUSTRIES, LLC 

5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541

In Canada: 

ZURN INDUSTRIES LIMITED 

7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292

Rev. C 

Date: 6/25/2018 

C.N. No. SAN008311  

Prod. | Dwg. No. CF1193

AQUASPEC FAUCETS

MODEL - Z86500-XL SERIES

CENTERSET METERING

TECHNICAL INFORMATION

®

1.  THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.
2.  REMOVE FAUCET BODY FROM CARTON AND PLACE FAUCET ON SINK.
3.  ATTACH MOUNTING NUTS (#7) ONTO SHANKS FROM UNDER SINK.
4.  HAND TIGHTEN MOUNTING NUTS (#7).  DO NOT OVER TIGHTEN, YOU COULD DAMAGE THE FIXTURE.
5.  ATTACH LAVATORY SUPPLY TO THE OUTLET OF THE SUPPLY STOP AND CONNECT TO FAUCET WITH RISER NUT
   (#8). 
6.  REMOVE MAINTENANCE TAG FROM SPOUT END AND ATTACH TO SHANK OF FAUCET UNDER SINK FOR FUTURE 
 

REFERENCE.  

7.  OPTIONAL - POP-UP (-P)/ GRID STRAINER (-G)/HANDICAP OFFSET GRID DRAIN (-GH): 
 

INSTALL POP-UP OR GRID STRAINER IN SINK OUTLET AND PLUMB WASTE CONNECTION.

8.  INSTALL  SPRAY OUTLET (#6) INTO FAUCET AND HAND TIGHTEN. 
9.  TURN WATER SUPPLY ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS.
10. METERING CARTRIDGE IS FACTORY PRESET FOR A 10 TO 15  SECOND CYCLE AT 80 PSI, IF ADJUSTMENT IS 
 

NECESSARY, SEE “ADJUSTING THE CYCLE TIME” SECTION (PAGE 2).

IMPORTANT 

THE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT 

FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS

IMPORTANT

 

THE FAUCET HAS AN INTEGRAL SHANK FILTER ASSEMBLY INSTALLED IN THE BODY UNDER THE 

METERING CARTRIDGE TO PREVENT FOREIGN MATTER AND DEBRIS FROM DAMAGING THE FAUCET. THE INTEGRAL 

FILTER MAY BE REMOVED TO BE BACK-FLUSHED AND CLEANED IF INSUFFICIENT FLOW IS DETECTED. THE INTE-

GRAL SHANK FILTER ASSEMBLY MUST BE RE-INSTALLED AFTER SERVICING TO ENSURE PROPER FUNCTIONING OF 

THE METERING CARTRIDGE.

*

*

FLOW:

  0.25 GPC MAXIMUM; PRESET AT FACTORY TO 10 TO 15 SECONDS @ 80 PSI ADJUSTABLE

MAXIMUM PRESSURE:

  80 PSI

MAXIMUM TEMPERATURE:

  140

O

 

F

*

INSTALLATION INSTRUCTIONS

FILTER REPLACEMENT

1) Remove handle and cartridge

2) Remove filter with 

1

4

" Allen wrench

3) Replace or clean filter, re-install filter
4) Install cartridge and handle

(SEE OTHER SIDE FOR ADDITIONAL
INSTRUCTIONS)

INSTRUCTION GUIDELINES

1) Flush supply lines thoroughly before installing faucet.

2) Install 1.0 or 0.5 GPM spray outlet only, hand tighten.
3) See under handle for run time adjustment.
Need Help? 1-800-997-3876 or visit www.zurn.com

(SEE OTHER SIDE FOR ADDITIONAL INSTRUCTIONS)

FILTER

(G68020)

SHANK

Remove this tag and place on supply line

Remove this tag and place on supply line

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Summary of Contents for AQUASPEC Z86500-XL-P Series

Page 1: ...PPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGN MATTER AND DEBRIS FROM CLOGGING AND OR DAMAGING INTERNAL COMPONENTS IMPORTANTTHE FAUCET HAS AN INTEGRAL SHANK FILTER ASSEMBLY INSTALLED IN THE BODY UNDER THE METERING CARTRIDGE TO PREVENT FOREIGN MATTER AND DEBRIS FROM DAMAGING THE FAUCET THE INTEGRAL FILTER MAY BE REMOVED TO BE BACK FLUSHED AND CLEANED IF INSUFFICIENT FL...

Page 2: ... ANY TRAPPED DEBRIS THERE ARE NO SERVICEABLE PARTS IN THE METERING CARTRIDGE CONTAMINATED OR DAMAGED METERING CARTRIDGE ASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLES 1A 1B WHILE TIGHTENING SET SCREW 1C TO ENSURE PRO...

Page 3: ... 1 3 G61754 Metering Cartridge Assembly 2 3A 58155020 O Ring 1 3B 81241001 Washer 1 4 G68020 Integral Shank Filter 2 5 92950003 4 102mm Centerset Body 1 6 G63561 13 16 27 Male Spray Outlet 0 25 1 7 G68042 Mounting Nut 1 8 G68043 1 2 NPSM Riser Nut 1 Item Part Number Description Qty 1 G61830 Dual Metering Handle Assembly 1 1A 60601002 Cold Metering Handle 1 1B 60601001 Hot Metering Handle 1 1C 6270...

Page 4: ...nt Remove handle item 1 using 3 32 Allen wrench Rotate adjustment nut item 2E down CW to lengthen handle stroke and increase cycle time Metering cartridge item 3 is damaged Replace metering cartridge item 3 G61754 per Installation and Maintenance guide page 2 Faucet is running too long or will not shut off Adjustment nut item 2E requires adjustment Remove handle item 1 using 3 32 Allen wrench Rota...